Climax Technology Co PCU Users manual

PPuullll CCoorrdd UUnniit
t
z
z
OOppeerraattiioonn
z Pull Cord Unit (PCU) is employed for radio control purpose during emergencies
involving fire, security, safety of life….and so on.
z When emergency switch is pulled down, the PCU will transmit a signal to panel and
LED will flash every 2 secs. PCU will continue to retransmit the signal every 5 mins.
z When the emergency switch is pushed up (return to standby position), the PCU will
perform 3 quick flashes and transmit restore signal to panel. The LED flash and PCU transmission will cease.
z
z
BBaatttteerryy
The PCU uses two 1.5V “AAA” Alkaline batteries. The PCU can detect low battery automatically by performing self test every 21 hrs. Low battery detection operates at a threshold of 2.3V ± 2%. If 3 consecutive signal
transmissions (spaced at least 30 secs apart) occur with battery below 2.3V, a low battery code will be sent with the 4
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
th
signal transmission.
PCU 2007.9.6