Climax Technology Co LS Users manual

ZigBee Light Switch: LS-1-ZBS(R) Series
Introduction
LS-1-ZBS(R) ZigBee Light Switch series include Master Light Switch and Slave Light Switch models. Depending on the models selected, the light switch can be deployed in single or 3-way installation according to requirement.
The Light Switch package is designed to be used in new installations or replace existing 3-way light switch to achieve home automation. After joining ZigBee network, the Light Switch package can be controlled via ZigBee network to activate remotely turn on/off household lighting.
The Master Light Switch utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission.
The Master Light Switch can also be bound to a ZigBee Controller to toggle On/Off the connected lighting.
Models with router function (LS-1A-G-ZBSR and LS-1E-G-ZBSR) also serve as a router in the ZigBee network. After being included in the ZigBee network, it allows other ZigBee device to join the network through the Light Switch.
Caution
The devices are intended for installation in accordance with the local wiring regulations such as the National Electric Code in the United States, the Canadian Electrical Code, or CSA C22.1, etc.. If you are unsure or uncomfortable about installing this device, please consult a qualified electrician in your area.
Parts Identification
Master Light Switch: LS-1A/E-G-ZBS(R)
LS-1E-G-ZBS(R) LS-1A-G-ZBSĀ®
1. Function Button
- Pressing the button to toggle on/off the switch.
- Press and hold the button for 10 seconds then release to reset the Light Switch.
- Press and hold the button for 3 seconds then release to bind with a controller
2. LED indicator
The LED indicator is used to indicate Light Switch status:
- On: The Light Switch is turned off.
- Off: The Light Switch is turned on.
- Flashes twice: The Light Switch has successfully joined a ZigBee network.
- Flashes five times The Light Switch has successfully bound with a controller
- Flashes every 20 minutes
1
The Light Switch has lost connection to its current ZigBee network (LS-1A-G-ZBS / LS-1E-G-ZBS only)
- Flashing continuously The Light Switch is overheated.
3. Air Gap Switch
- Pulled out: Completely removes the power available to the load. This enables the connected lighting (bulb,
tube, etc.) that is controlled by the light switch to be changed with minimal danger of electrical shock.
Use a flat-head screwdriver to pull the switch out.
- Pushed in: For normal operation of the light switch.
Connection Terminals
Insert a flat-head screwdriver to open the clipper for each terminal and connect wiring. Remove the screwdriver to close the clipper and hold wire in place.
4. Line Terminal
5. Load Terminal
6. Neutral Terminal
7. Travel Terminal
Master Light Switch: LS-1A/E-B (Rechargeable Battery)
LS-1E-B-ZBS LS-1A-B-ZBS
1. Function Button
- Pressing the button to toggle on/off the switch.
- Press and hold the button for 10 seconds then release to reset the Light Switch.
- Press and hold the button for 3 seconds then release to bind with a controller
2. LED indicator
The LED indicator is used to indicate Light Switch status:
- On: The Light Switch is turned off.
- Off: The Light Switch is turned on.
- Flashes twice: The Light Switch has successfully joined a ZigBee network.
- Flashes five times The Light Switch has successfully bound with a controller
- Flashes every 20 minutes The Light Switch has lost connection to its current ZigBee network (LS-1A-B-ZBS only)
3. Air Gap Switch
- Pulled out:
2
Completely removes the power available to the load and charges the rechargeable battery of the Light Switch. This enables the connected lighting (bulb, tube, etc.) that is controlled by the light switch to be changed with minimal danger of electrical shock.
For the first time installation of LS-1A-B Light Switch, Air Gap Switch must be pulled out to charge the rechargeable battery of the Light Switch.
Use a flat-head screwdriver to pull the switch out.
- Pushed in: For normal operation of the light switch.
Connection Terminals
Insert a flat-head screwdriver to open the clipper for each terminal and connect wiring. Remove the screwdriver to close the clipper and hold wire in place.
4. Line Terminal
5. Load Terminal
6. Travel Terminal (LS-1A-B-ZBS Only)
Slave Light Switch: LS-1A/E-S
1. Switch Button
- Pressing the button to toggle on/off the connected lighting.
2. LED indicator
The LED indicator is used to indicate Light Switch status:
- On: The Light Switch is turned off.
- Off: The Light Switch is turned on.
3. Air Gap Switch
- Pulled out: Completely removes the power available to the load. This enables the connected lighting (bulb,
tube, etc.) that is controlled by the light switch to be changed with minimal danger of electrical shock.
Use a flat-head screwdriver to pull the switch out.
- Pushed in: For normal operation of the light switch.
Connection Terminals
Insert a minus screwdriver to open the clipper for each terminal and connect wiring. Remove the screwdriver to close the clipper and hold wire in place.
4. Line Terminal
5. Travel Terminal
Front Cover
A. Switch Cover
B. Light Switch Base
3