REMOTE KEYPAD (KP-23B-EL / KP-23B-EL-F1) Jul-5-2016
z Identifying the Parts
1. Active LED
2. Status LED
3. Fault Display LED
4.
Arm Key
10. Send Learning Code
- Press both # and ¿ keys together to Send Learning
Code
11. Medical Alarm (if enabled)
- press both 7 and 9 to trigger medical alarm
12. Fire Alarm (if enabled)
5.
6. Χ Key
7. Disarm Key
8. # Key
9. ¿ Key
<NOTE>
&
Home Key
- press both 4 and 6 to trigger fire alarm
13. Panic Alarm (if enabled)
- Check Control Panel Status
-press both 1 and 3 to trigger panic alarm
14. Battery Insulator
- to move back one step
15. Mounting Holes
16. Tamper Swtich
- Enter KP Pin Code + ¿ Key to enter Test Mode
A short beep will sound along with key pressing to indicate that the button pressed is valid.
& 4 continuous beeps will sound indicating mistake and the user should repeat the process again.
z LED Indicator
z Active LED (Blue/Amber):
z Blue LED on 5 seconds: the system is in Normal Operation Mode.
z Blue LED flashes for 5 seconds: low battery in Normal Operation Mode.
z Amber LED on: the system is in Test Mode.
z Amber LED flash: low battery in Test Mode.
z Status LED (Blue/Red):
z Red LED on: the system is in Away Mode
z Red LED flash: the system is in Home Mode.
z Blue LED on: activation of Disarm Mode.
z Blue LED flash: failure due to the following reasons:
¾ No response sent by the control panel within 4 seconds.
¾ Control Panel User PIN code was incorrect.
1
¾ Request for Home mode during Arm mode.
¾ Request for Force arm.
z Fault LED (Amber):
z Flash: system failure (panel tamper, AC fault, sensor temper, sensor out of order, open door)
z On: Alarm Memory (depend on Control Panel).
z Power
z Remote keypad uses one EL123AP 3V Lithium battery as its power source.
z Remote keypad can also detect the battery status. If the battery voltage is low, the Active LED will flash (Amber in Test
mode or Blue in Normal mode) during operation. The Low battery signal will be sent along with regular signal
transmissions to the Control Panel for displaying the status accordingly.
z Before shipment, the battery is pre-installed by the factory. Pull out the battery insulator to activate battery.
z When changing battery, press the tamper switch a couple time after removing old battery to discharge, then insert the
new battery.
z Power Saving Feature
z When idle, Remote keypad is in Stand-by mode and uses no power. It will activate an d wake-up for 5 seconds when
any key is pressed.
z After 5 seconds of key inactivity, the power goes off and it returns to Stand-by mode.
z Upon completion of a command input, the power goes off and Remote keypad returns to Stand-by mode.
z Test Mode
z Remote keypad can be put into Test mode by e ntering the Keypad PIN code (def ault: 0000) follo wed by * key. The
Active Amber LED will turn on along with a long beep.
z To exit Test mode, press key twice, Remote keypad will sound a long beep and the Active LED will turn off, then
Remote keypad returns to Normal Operation mode. Otherwise, Remote keypad will automatically exit Test mode after
5 minutes and return to Normal Operation mode.
<NOTE>
&
The Test Mode is helpful for bypassing Remote keypad Tamper alarm when installing, replacing low batteries or
removing to different mount site.
& When Remote keypad is in Test mode, it operates as wake-up condition and will NOT disconnect after 5 seconds.
Test Mode Function:
Press * key and then 7 key — Transmit Remote keypad learn signal
Press * key and then 2 key — Enable Dual-key Panic Alarm function
Press * key and then 3 key — Enable Dual-key Fire Alarm function
Press * key and then 4 key — Enable Dual-key Medical Alarm function
Press * key and then 5 key — Disable all Dual Key function (Default)
Press * key and then 6 key — Edit Keypad Pin Code
Enter Old Keypad Pin Code and then press Χ key
Enter New a new 4-digit Keypad Pin Code and then press # key.
Press
Press * key and then 8 key — Enable Arm/ Home without PIN Code function
Press * key and then 9 key — Enable Arm/ Home with Control Panel User PIN Code function (Default)
key twice — to leave the Test Mode.
z Tamper Protection
z The keypad is protected against any attempt to open the lid or to detach keypad from its mounting surface.
z Tamper protection is disabled when the keypad is in Test Mode.
z Installation Procedures
Step 1. Put the Control panel into learning mode, .
Step 2. Adding remote keypad into the Control Panel:
Test Mode Learning:
I. Put remote keypad in Test mode by entering KP PIN code (default: 0000), then press * key. The Active
Amber LED will turn on along with a long beep sound.
II. Press * key then 7 key. Remote keypad will sound a long beep.