DC-16SL-ZBS Door Contact
Introduction
DC-16SL-ZBS is a ZigBee Door Contact. It is capable of sending wireless signals to the coordinator in the
ZigBee network upon detection of door/window opening.
The Door Contact utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless
communication protocol that is reliable and has low power consumption and high transmission efficiency.
Based on IEEE802.15.4 standard, ZigBee allows a large amount of devi ces to be included in a network and
coordinated for data exchange and signal transmission
The Door Contact serves as an end device in the ZigBee network. It can be included in the ZigBee network to
transmit signal upon activation, but cannot permit any other ZigBee device to join the network through the Door
Contact.
Parts Identification
1. LED indicator
The LED indicator lights up in the following conditions:
- Flashes twice quickly:
The Door Contact has successfully joined a ZigBee network.
- Flashes once every 20 minutes:
The Door Contact has lost connection to its current ZigBee network.
- Flashes under normal operation
The tamper switch is triggered
2. Function Button
- Press the button once to send a supervision signal.
- Press and hold the button for 10 seconds then release to reset the Door
Contact.
3. Tamper Switch
The Tamper switch will be activated when the Door Contact is removed from
mounted surface, or it cover opened.
4. Battery Compartment
The Door Contact is powered by one CR-2 3V Lithium battery.
5. Mounting Knockouts
6. Battery Insulator
7. Rib-Mark
8. Magnet
Features
Battery and Low Battery Detection
The Door Contact uses one CR2 3V Lithium battery as its power source. The battery is installed in the
battery compartment with a battery insulator inserted. To activate the battery, simply pull out the battery
insulator.
The Door Contact feature Low Battery Detection function. When the battery voltage is low, the Door
Contact will transmit Low Battery signal to notify the user.
When changing battery, after removing the old battery, press the Tamper Switch twice to fully discharge
before inserting new battery
Tamper Protection
The Door Contact is protected by a tamper switch which is compressed against the mounting surface when
mounted. Whenever the Door Contact is removed from mounted location, or its cover opened, the tamper
switch will be activated and the Door Contact will send a tamper open signal to remind the user of the
condition.
Supervision
The Door Contact will transmit a supervision signal to report its condition regularly according to user s etting.
Supervision
Tamper Protection
Battery and Low Battery Detection
1

T
he factory default interval is 30 minutes. The user can also press the Function B utton once to transmit a
supervision signal manually.
ZigBee Network Setup
ZigBee Device Guideline
ZigBee is a wireless communication protocol that is reliable and has low power consumption and high
transmission efficiency. Based on IEEE802.15.4 standard, ZigBee allows a large amount of devices to be
included in a network and coordinated for data exchange and signal transmission.
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join n etwork after
powering on. Since performing a task in connecting network may consume some power, it is required to
follow the instructions to avoid draining battery of a ZigBee device
- Ensure your ZigBee network router or coordinator is powered on before inserting battery into the ZigBee
device.
- Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee device is
in use.
- Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the
battery from a ZigBee device.
Joining the ZigBee Network
As a ZigBee device, the Door Contact needs to join a ZigBee network to transmit signal when it is triggered.
Please follow the steps bellow to join the Door Contact into the ZigBee network.
1. Pull out the battery insulator; this will connect the battery to power on the Door Contact.
2. After powering up, press and hold the Function button for 10 seconds, then release it to join the
network. Please make sure the permit-join feature on the router or coordinator of your ZigBee network
is enabled.
3. If the Door Contact successfully joins a ZigBee network, the LED Indicator will flash twice to confirm.
4. After joining the ZigBee network, the Door Contact will be registered in the network automatically.
Please check the ZigBee coordinator, system control panel or CIE (Control and Indicating Equipment)
to confirm if joining and registration is successful.
5. After joining the ZigBee network, if the Door Contact loses connection to current ZigBee network, the
LED will flash every 20 minutes to indicate. Please check your ZigBee network condition and Door
Contact signal range to correct the situation.
Removing Device from ZigBee Network (Factory Reset)
To remove the Door Contact from current ZigBee network, the Door Contact must be put to Factory Reset
to complete device removal. Factory Reset function will clear the Door Contact of its stored setting and
information and prompt the Door Contact to search for new ZigBee network.
Before removing device, make sure the Door Contact is within current ZigBee network signal range
1. Press and hold the function button for 10 seconds, then release the button to reset Door Contact.
2. Upon reset, the Door Contact will clear current ZigBee network setting and transmit signal to ZigB ee
coordinator to remove itself from current ZigBee network. It will then actively search for available
ZigBee network again and join the network automatically.
ZigBee Device Guideline
Joining the ZigBee Network
Removing Device from ZigBee Network (Factory Reset)
Installation
Installation Guideline
The Door Contact should be installed on the door/window frame, and the magnet on the door/window
The distance between the Door Contact and the magnet sh ould be no mor e than 15mm when the do or
is closed.
Avoid mounting the Door Contact on metallic surface. If mounting on metallic surface, make sure the
Door Contact can be triggered when the door is opened and the signal can be received successfully by
Control Panel.
Mount the Door Contact as high as possible.
Using Door Contact with ZigBee Router
IMPORTANT NOTE
If the Door Contact installation location is away from your system control panel and requires ZigBee routers
to improve signal strength. DO NOT use a ZigBee Router without backup battery. A ZigBee router without
battery will be powered down during AC power failure and the Door Contact connected to the router will
lose connection with ZigBee network. You should plan your Door Contact installation location using only
ZigBee router with backup battery.
Mounting the Door Contact
1. Find a suitable location close to your door/window to install the Door Contact.
2. The Door Contact has 2 rib-marks on one side (refer to figure), marking the internal magnet switch
Installation Guideline
Using Door Contact with ZigBee Router
Mounting the Door Contact
2

location. The door contact should be installed either upright or inverted to ensure that the rib-marked s id e
faces the magnet.
3. To mount the Door Contact:
a) Locate the 2 Door Contact mounting knockouts, break through the knockouts and use th e ho les as
template for appropriate hole positioning. Mark mounting location on the door/window frame.
b) Insert the provided wall plugs for plaster/brick installation if required.
c) Screw the Door Contact into the wall plugs.
Alternatively, you can also choose use double side adhesive tape to mount the Door Contact
4. Fit the magnet on the door using the small piece of d oub le s ided ad hesiv e tape or with provided scr ews.
The magnet must align with the rib-mark side of the Door Contact as shown in figure. T he distance
between the Door Contact and the magnet should be no more than 15mm.
Door/
Windo
w
Frame
Appendix(For developers only)
Door Contact Cluster ID
Device ID: IAS Zone 0x402
Endpoint: 0x01
Server Side Client Side
Basic (0x0000)
Identify(0x0003)
IAS Zone(0x0500)
None None
Door Contact Cluster ID
Mandatory
None
Optional
Attribute of Basic Cluster Information
Identifier Name Type Range Access Default
0x0000
0x0001 ApplicationVersion
0x0003
0x0004
0x0005
0x0006
0x0007
ZCLVersion
HWVersion
ManufacturerName
ModelIdentifier
DateCode
PowerSource
Unsigned 8-bit
integer
Unsigned 8-bit
integer
Unsigned 8-bit
integer
Character
String
Character
String
Character
String
8-bit 0x00 –0xff Read M
0x00 –0xff
0x00 –0xff
0x00 –0xff
0 – 32 bytes
0 – 32 bytes
0 – 16 bytes
3
Attribute of Basic Cluster Information
Mandatory
/ Optional
Read
only
Read
only
Read
only
Read
only
Read
only
Read
only
0x01 M
0x00 O
0 O
Climax
Technology
(Model Version) O
O
O

only
0x0010
0x0011
0x0012
LocationDescription
PhysicalEnvironment
DeviceEnabled
Attribute of Identify Cluster Information
Character
String
0 – 32 bytes
8-bit 0x00 –0xff
Boolean 0x00 –0x01
Identifier Name Type Range Access Default
0x0000
IdentifyTime
Attribute of IAS Zone Cluster Information
Unsigned
16-bit integer
0x00 –0xffff
Identifier Name Type Range Access Default
0x0001
0x0002
0x0003
0x0010
0x0011
ZoneState
ZoneType
ZoneStatus
IAS_CIE_ADDRESS
ZONE_ID
8-bit
Enumeration
8-bit
Enumeration
16-bit bitmap All
IEEE
ADDRESS
Valid 64bit
IEEE address
Unsigned 8-bit
integer
All
All
All
Read /
Write
Read /
Write
Read /
Write
Attribute of Identify Cluster Information
Read /
Write
Attribute of IAS Zone Cluster Information
Read /
Read
only
Read
only
Read
only
Write
Read
only
O
0x00 O
0x01 M
Mandatory
/ Optional
0x0000 M
Mandatory
/ Optional
0x00 M
M
0x00 M
M
0xFF M
4

Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following
measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
: To assure continued compliance, any changes or modifications
not expressly approved by the party responsible for compliance could void
the user's authority to operate this equipment. (Example - use only shielded
interface cables when connecting to computer or peripheral devices).
FCC Radiation Exposure Statement
This equipment complies with FCC RF radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20 centimeters between the radiator
and your body.
This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
The ant
separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or
transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
ennas used for this transmitter must be installed to provide a
5