Climateright CR2500ACH, CR10000ACH, CR5000ACH User Manual

OWNER’S MANUAL
Operating and Servicing Instructions
PORTABLE AIR CONDITIONER & HEATER ACH SERIES
Portable Air Conditioner & Heater
Questions or concerns? For assistance, please call Customer Service
ClimateRight® USA
CR2500ACH
www.climaterightair.com Ph: 800-725-4628
8 62752 00006 2
CR5000ACH CR10000ACH
*CR10000ACH varies slightly from this picture
CR2500ACH • CR5000ACH • CR10000ACH
IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE
Read and follow all safety rules and instructions before operating this equipment.
Please keep this manual for future reference.
PACKAGE CONTENTS
CLIMATERIGHT® CR2500ACH, CR5000ACH, CR10000ACH Portable Air Conditioner and Heating Unit.
Thank you for choosing a ClimateRight
®
product. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new ClimateRight
®
Portable Air
Conditioning and Heating Unit.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:
Store Name: ______________________________________________________________
Location: _________________________________________________________________
Date Purchased: ___________________________________________________________
Serial Number (located on back of unit): ______________________________________
IMPORTANT INSTRUCTIONS
Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference.
1) Do not permanently mount unit to moving vehicles.
2) Always place the unit on a level surface.
3) Never use or store gasoline or other flammable vapor or liquid near this unit
aaaunless instructed by this manual.
4) The unit must be connected to a correctly grounded power supply.
5) Do not start or stop the unit by inserting or pulling out the power plug.
6) Do not use an adapter plug or extension cord.
7) Do not use the unit in the immediate surroundings of a bath, a shower or a
swimming pool.
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills
unless instructed by this manual.
9) Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is
damaged, it must be replaced by the manufacturer or qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.
Models: CR2500ACH, CR5000ACH, CR10000ACH
(1) ClimateRight® Air Conditioning and
Heating Unit
(1) Remote Control
(2) AAA batteries
(1) Owner’s Manual
2 x ClimateRight Unit Connector Flange
4 x Flange Cap
CR2500ACH and CR5000ACH
CR10000ACH UNIT FEATURES
Quick Connect Hose System
(2) ClimateRight® Unit Connector Flanges
(Pre-mounted to ClimateRight®)
(2) Flexible Air Hoses
(4) Hose Flanges (Pre-mounted to Hoses)
(2) Building Flanges
(4) Flange Caps
2 x Flexible Air Hose
4 x Hose Flange
2 x Building Flange
1 2
SAFETY INSTRUCTIONS
CAREFULLY READ THESE INSTRUCTIONS BEFORE USING
STOP
General Information
• Never perform any maintenance procedures until the electrical power to the unit is turned off and unplugged.
• Never remove any panel from the unit while it is operating.
• For safety purposes, the information in this manual must be followed to minimize
• Use this appliance only for its intended purpose as described in this Owner’s Manual.
• This air conditioner must be properly installed in accordance with the Installation
Instructions before it is used.
e to
comply may void the warranty.
liquids in the vicinity of this or any other appliance.
• This product contains refrigerants. As required by federal law, refrigerants must
be removed prior to disposing of this product. To dispose of this product, contact the local waste disposal service to ensure safe and proper disposal according to federal, state and local laws.
• Save these instructions.
• For additional FAQ’s, please visit www.climaterightair.com for the most up to date information.
SAFETY PRECAUTIONS
• Do not use the unit if the power cord is frayed, cracked or otherwise damaged.
A damaged power cord must be replaced with a new power cord obtained from the manufacturer and not repaired. Contact ClimateRight® for repair and replacement details.
• Never unplug the unit by pulling on the power cord. Always grip
• Connect to a properly grounded 120V outlet. Do not remove the ground prong. The power outlet must be easily accessible and located within the length of the power cord supplied with the unit.
• This unit is designed for outdoor use. When plugging the unit
into an outdoor outlet, the outlet must be a GFCI outlet and have a weatherproof while-in-use receptacle cover.
• The unit should be plugged into its own circuit. If other devices are plugged into the same circuit, the fuse or breaker may trip due to excessive amperage draw.
• Internal parts of the unit may get hot such as the condenser, compressor and copper piping. Do not remove the outer cover and touch these parts.
• There are moving parts inside the unit. Do not put any body part inside of the unit.
Use of Extension Cords
Use of an extension cord is not recommended. Using an extension cord could prevent the unit from operating normally and
unit is located near a 3-prong 120V GFCI outlet. If one is not near, a
3 4
Loading...
+ 5 hidden pages