Climate Control CCS-22HR4GP Owner's Manual

OWNER'S MANUAL
Models:
WALL SPLIT TYPE
WALL SPLIT TYPE
carefully before operating the unit and keeps it carefully
Thank you for choosing our air conditioner
for correct operation, please read this owner's manual
for consultation.
66129903302
Climate Control
Climate Control
Climate Control
5
6
10
15
17
18
20
21
22
12
ƾ
ƾ
The air conditioner should be
operated with the voltage range
the rated voltage is 220-240V
,
when the voltage is very low, the compressor vibrates terribly and that will damage the refrigerant system; When the voltage is very high, the electrical component
would be easily damaged.
that is the rated voltage 10%,
Operation and maintenance-Notices for operation
Please read the following carefu lly befo re op erating.
WARNING
When having a burning smell or smoke, please turn off the power
supply and contact with the service
may be damaged, and may cause
center of ours.
If the abnormity still exists, the unit
electric shock or fire.
Don't operate the air conditioner
with wet hands.
Otherwise, it can cause an electric shock or fire.
Never cut off or damage power cables and control wires. If the power cable and signal control wire were
damaged, change them by professional
Power must adopts the special
circuit to prevent fire.
Otherwise, it can cause an electric
shock or fire.
Be sure to pull out the power
plug as the air conditioner not in use
for a long time.
Otherwise, the accumulated dusts
that may cause overheating or fire.
Never damage the electric wire
or use the electric wire, which is not
appointed.
Otherwise, it will cause overheating
or fire.
When cleaning, it is necessary to stop driving and turn off the power supply.
Cut off power supply
Otherwise, it may cause electric
shock or damage.
The power supply must adopt
the special circuit that with air switch
protection and assure it has enough capacity. The unit will be turned on or off according to your requirement automatically, please do not turn on
or turn off the unit frequently, othe-
rwise disadvantage effect may be caused to the unit.
ƾ

ƾ
ƾ
ƾ
ƾ
ƾ
 ć
ƾ
Earth:The ground
be connected!
If not, please ask the qualified person­nel to install. Furthermore, don't conn­ect each wire to the gas pipe, water pipe, drainage pipe or any other impr-
oper places.
Select the most appropriate tem-
perature.
It can preclude the electricity wasted.
Keep room coo-
er than outside
about
Don't leave windows and
doors open for a long time
while operating the air conditi­oner.
Don't block the air intake or outlet vents of both the outdoor and indoor units.
Keep combustible spray away
from the units more than 1m.
It can cause afire or explosion.
It can decrease the air conditioning
capacity or cause a malfunction.
It can decrease the air conditioning capacity.
Please note whether the install-
ed stand is firm enough or not.
If it is damaged, it may lead to the fall of the unit and cause the injury.
As falling off the outdoor unit can be dangerous.
Don't step on the top of the outdoor unit or place something on it.
Don't attempt to repair
the air conditioner by yourself.
The wrong repair will lead to
an electric shock or fire, so
you should contact the service center of ours to repair.
ƾ
Be sure to pull out the power
plug when not using the air co-
nditioner for a long time.
Otherwise, the accumulated dust
may cause fire or electric shock.
Notices for operation
ƾ
ƾ
ƾ
ƾ
ƾ
ƾ
Don't blow the wind to animals and plants
directly. It can cause a bad influence to them.
Don't insert your hands or stick into the air
intake or outlet vents.
Splashing water on the air conditioner can
cause an electric shock and malfunction.
Don't place a space heater near the air
conditioner.
Or CO toxicosis may occur for imcomplete burning.
Don't apply the cold wind to the body for a
long time.
It can cause the health problems.
Don't use the air conditioner for other purposes,
such as drying clothes, preserving foods, etc.
The power cords of this air conditioner adopt
X-type connection, please don't cut off or damage
the power cords and control cords. If they are damaged, please ask the qualified personnel to
change them.
To adjust the airflow and direction appropriately.
At operating the louvers of air conditioner could be
adjusted by pressing the SWING button on wireless
remote control to change the airflow direction.
Guide louver
Notices for operation



 

ƾ
ć
ć
ć
ć
ć
ć
Notices for use
Working p ri nc ip le and sp eci al f un ctions f or co ol ing
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
An ti-fr eezi ng fu ncti on
If the unit is running in COOL mode and in low termperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0ć, the indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, will increase, its heating capacity will decrease by outdoor ambient temperature. so that indoor ambient temperature increased, so room heating capacity. This heating air circulation system can enhance the indoor temperature in a short while. If outdoor temperature got lower, please operate with the other heating ventilating
equipments.
Defrosti ng :
When outdoor temperature is low but high humidity, after a long while running, frost will form on outdoor unit, that will effect the heating effect, at this time,
the auto defrosting function will act, the heat running will stop for 8-10mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor. This is due to the defrosting, it isn't malfunction. After defrosting finished,the heating will recover automatically.
Anti-fr eezin
g funct io n:
In "HEAT" mode, if in the following status, the indoor heat exchanger haven't achieve the certain temperature, that the indoor unit will not act, in order to prevent cool air blowing. (Within 3mins)
1.Heating starts. 2.After Auto defrosting finished. 3.Heating under the low temperature.
The condi ti on s o f u nit can't normally r un
The following temperature range protection device may act, that may cause stop running.
"HEAT" running
Under the relative humidity above 80%( doors and windows opened) when cooling or dihu­midifying for a long time, there will be dew drip off near the air vent.
"COOL" running
"DRY"
running
Outdoor temp above
Outdoor temp below
Indoor temp. above
Outdoor temp above
Indoor temp. below
Indoor temp. below
ྦ
Air in
Air out
Filter
Guide louver
Wall pipe
Bind tape
Window receiver
Drainage pipe
Power cords
Air in
Air out
Ŋ
ŋ
Ņ
Wireless remote control
Heat
COOL Set TEMP.
RUN
indicator
DRY
Window
receiver
ń
ł
ņ Ň
ň
ʼn
Ŋ
Ł
Display board
Front panel
Ń
ŋ
ʼn
Ń
Ņ
ń
ņ
Ň
ň
Ł
Ń
ł
Indoor unit
Outdoor unit
Manual switch
Connection wire
Names and functions of each part
6
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
Operation of wireless remote control
Name and fun ct io n o f w ireless remote co nt ro l
Note: Be sur e th at t here are no obstruct io ns bet ween recei
ver and remo te c on tr oo ler ;
Don't drop or th ro w t he r emote control; Don 't let any li qu id in the remote
contro l an d
put the r emo te c on tr ol directly un der th e su nl ight or any plac e wh ere i s v ery hot.
Signal t
ransm it ter
Temperatur e bu tt on
TEMP.
Remote control
ON/OFF
MODE
Mode butt on
ON/OFF button
Press this button, the unit will start to run, when repressed, the unit will stop to run.
Press this button, the running mode will change as below.
AUTO
COOL
DRY
FAN
(only for cooling and heating unit)
FAN
Fan speed button
Press this button once, fan speed will change
as follow:
AUTO
Low fan
Middle fan
High fan
SWING
SWING button
When pressing+, the setting temperature
will be increased , when pressing -,
the setting temperature will be decreased
(When continuously press and holding
ć
ć
+ or-button, the temperature will be changed quickly). The temperature setting range is 16-30
ć
COOL
HEAT
COOL butto n
HEAT butto n
At operating, pressing this button could enter into the COOL mode directly.
At operating, pressing this button could
enter into the HEAT mode directly.
Pressing this button once the guide louver will start swing at certain angle, when repressed, it will stop swing.
Pressing this button, will display the last Timer setting, and sample of Hour Off (On) will flash. At this time, to press + or - button could adjust the Timer (when continuously press and holding
+ or - button, the time value will be changed swiftly) the setting range is 0.5-24hour; when pressing this button again to confirm the time, to send relevant information by the wireless remote control immediately, that the sample of Hour Off (On) will not flash anymore. If it is flashing, and the TIMER button hasn't been pressed, it will quit the Timer setting after 10s. At operating, press this button could set Timer off; When the unit is stopped, press this button could set Timer on. If the time has been confirmed, and repress this button will cancel the TIMER.
TIMER
TIMER button
HEAT
ƽ
ć
ƽ
ƽ
ƽ
ƽ
ƽ
Operation of wireless remote control
Names and fu nc ti on s o f wireless rem ot e co nt ro l
This wireless remote control is universal, and it could
be used for many units, some buttons
of this co nt ro l w hich are not avail abl e to th is unit will not be
descr ib ed b elo w.
Wireless remote contr ol
SLEEP
TURBO button
TURBO
At COOL and HEAT mode, press this button could set TURBO ON (and displays "TURBO") or OFF ("TURBO" disappear). After powered on, it is default to TURBO OFF. At AUTO, DRY, FAN mode, the TURBO function cannot be set, and there is no "TURBO" displayed.
BLOW
BLOW butt on
SLEEP button
At COOL and DRY modes, press this button, could
set BLOW ON (and Displays the "BLOW") or OFF (the
"BLOW" will disappear). After powered on,that is default
to BLOW OFF. At AUTO, FAN or HEAT modes, the
BLOW function cannot be set, and there is no "BLOW"
displayed.
Pressing this button, enter into SLEEP state or
quit the SLEEP state. After unit is turned off and
cancel the SLEEP function. At FAN and AUTO mode, the SLEEP function cannot be set. Is for SLEEP.
At COOL, DRY mode: Enter into SLEEP state
and after one hour running later, the temp. of main unit be increased 1 , 2hours later, the
setting temp. will be increased 2 , after pressing this button, the unit normally runs at the setting
temp.
In HEAT mode: After entered the SLEEP mode and run for 1hour later, the temperature of main unit will be decreased 1 , 2hours later, setting temperature will be decreased 2
, after pressing this button, the unit normally runs at the setting
temp. After SLEEP mode is set up, the setting of wireless remote control will not change.
ć
ć
ć
Light
LIGHT button
Pressing this button, can select the Light On and Light Off.
ƾ
ƾ
Operation of wireless remote control
Guide for op erat io n- g eneral operation
1. After powered on, press ON/OFF button, the unit will start to run.(Note: When it is powered on, the guide louver of main unit will close automatically.)
2. Press MODE button, select desired running mode, or press COOL or HEAT mode to enter into the corresponding operation directly.
3. Pressing +or - button, to set the desired temperature (It is unnecessary to set the temp. at AUTO mode.)
4. Pressing FAN button, set fan speed, can select AUTO FAN, LOW, MID and HIGH.
5. Pressing SWING button, to select the swing.
Guide for op erat io n- Op tional operation
1. Press SLEEP button, to set sleep.
2. Press TIMER, +and- button, can set the scheduled timer on or timer off.
3. Press LIGHT button, to control the on and off of the displaying part of the
unit (This function may be not available for some units).
4. Press TURBO button, can realize the ON and OFF of TURBO function.
The above op erat io n p leas e refers to Page 8, Page 9 for det ail s.
Introdu ct io n f or special functi on s
About AUTO mode When AUTO mode is selected, the setting temperature will not be displayed on the LCD of the wireless
remote control, according to the indoor temperature, unit will automatically select the appropriate running
mode, to make the environment comfortably, without the user to operate.
About DRY Function
The DRY function is used for after the unit turned off, to dry the moisture on the evaporator of indoor unit,
in order to prevent the moldy.
1. The DRY ON has been set up: At this time, press ON/OFF button, the whole unit will be turned off, but the
indoor fan motor still run at low fan speed for a while and then stop. During this course, repress the
BLOW button, can stop the indoor fan motor directly.
2. The DRY OFF has been set up: At this time, press ON/OFF button, the whole unit will directly turn off.
9




ƾ
ƾ

ƾ
ƽ
ƽ
ƽ ƽ ƽ
ƽ
Operation of wireless remote control
About t he Su per Str on g f unction
When the Super Strong function is turned on, the whole unit runs at the high fan speed, and runs at the
Quick COOL or Quick HEAT operation, to make the ambient temperature swiftly approach to the setting
temperature. Turn off the Super Strong function, the whole unit runs at the setting fan speed.
About L OCK
To press + and - button, can lock or unlock the keyboard, after locked, the symbol of the lock will be displayed
at this time, to press any key, the symbol will flash for 3 times. After it is unlocked, the symbol will disappear.
Changing bat ter ies and notices
Slightly to press the place with , along the arrowhead direction to push the back cover of wireless remote
control. (As show in figure)
Take out the old batteries. (As show in figure)
Insert two new AAA1.5V dry batteries, and pay attention to the polarity. (As show in figure)
Attach the back cover of wireless remote control. (As show in figure)
When changing the batteries, do not use the old or different batteries,
If the wireless remote control will not be used for a long time, please
otherwise, it can cause the malfunction of the wireless remote control.
take them out, and don't let the leakage liquid damage the wireless remote control.
The operation should be in its receiving range.
It should be placed at where is 1m away from the TV set or stereo sound sets.
If the wireless remote control cannot operate normally, please take them out,
after 30s later and reinsert, if they cannot normally run, please change them.
When it is need to control the main unit, please aim at the receiving device, in order to improve the sensitivity
Sketch map for changing batteries
NOTE:
of the main unit. When the wireless remote control is sending information, the symbol will flash 1s. The main unit is receiving the information, will send a sound.
ƽ
ƽ
Emergency ru nn in g
When the wireless remote control is lost or damaged, please use
the manual switch, at this time, it is running in Auto Run mode,
that will not change the temperature setting value and fan speed.
At operation: When the unit stopped running, press ON/OFF button, unit will enter into AUTO RUN mode. The microcomputer will accord to the room temperature to select the (COOL, HEAT, FAN) mode automatically, to obtain the comfortable effect.
work.
At stopping: When the unit is running, press the ON/OFF button of the manual switch, the unit will stop
Auto/ Stop
Manual switch

ʎ
ʎ
ʎ
ĹInstall front panel
)b*
)c*
ķ
ĸ
Ĺ
Clean and care
Caution
Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock.
Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock.
Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft
cloth, or a cloth slightly moistened with water or cleanser.)
Clean the front panel (make sure to take it off before cleaning)
Place two supporters of the front panel into the slots, along the direction of arrowhead to cover and clasp the front panel. As show
in Fig.4(a,b)
Fig.4
Clean the air fi lt er (Rec ommended once every t hr ee mo nt hs )
Note: If du st is mu ch more around the ai r
condit io ner , th e air filters shoul d b e cl eaned
many tim es. A ft er t aking off the filt er, d on 't to uc h t
he fin of in do or un it, in order to avoi d
hurt yo ur fi ng ers .
At the slot of surface panel to open an angle, pull the air filter downward
and take it out, please see the Fig. 5(a,b).
To clean the dust adhering to the filters, you can either use a vacuum cleaner, or wash them with warm water (the water with the neutral detergent
should below 45 ), and dry it in the shade.
Reinsert the filters along the direction of arrowhead, and then to cover
the cover and clasp it.
Take down t he ai r f il ter
Note: Never u se w ater abo ve 45
o
C to clean, o r i t c an c aus e deformat io n o r d is coloration. Never par ch it by fire, or can cause a fir e
or defor mat io n.
Insert th e air fi lt er
Fig. 5
Clean the air fi lt er
D
E
ķ
ĸ
Take off the front panel
Along the direction of arrowhead to lift up the front panel, and after disassembled the displayer, to pull the front panel at the both slots of the front panel,then take it off.
Washing Clean with a soft hairbrush, water and neutral detergent, then to dry it in the shade.(Note: Before cleaning, please take
water above 45ćto wash the panel, or it could cause deformation or discolouration.
off the displayer at first, then clean the front panel, in order to prevent the water damage and never use the
DŽ
&

ķ
ĸ
Ĺ
ĺ
ķ
ĸ
Ĺ
ĺ
Clean and care
Check before use
Be sure that nothing obstructs the air outlet and intake vents.
Check that whether ground wire is properly connected or not.
Check that whether the batteries of air conditioner are
changed or not.
Check that whether the installation stand of the outdoor unit is damaged or not. If damaged, please contact the dealer.
Maintain after use
Turn main power off.
Clean the filter and indoor and outdoor units' bodies.
Clear dust and obstructions from the outdoor unit.
Repaint the rubiginous place on the outdoor unit to prevent it from spreading.

ʎ
Troubleshooting
CAUTION
Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire.
Please check the following items before asking for repair, it can save your time and money.
TroubleshootingPhenomenon
Once the air conditioner is stopped, it will
not operate in approximately 3minutes to
protect itself.
Not operate immediately when the air conditioner is restarted.
The unit has no peculiar smell by itself. If has,
that is due to the smell accumulated in the ambient. Solution method: Cleaning the filter. If problem still has, so need to clean air conditioner. (please contact with GREE authorized maintenance center.)
There's unusual smell blowing from the
outlet after operation is started.
Sound of water flow can be heard during the operation.
The air conditioner is started, when it is running the compressor started or stopped running, or
the unit is stopped, sometimes there is swoosh
or gurgle, the sound is due to refrigerant flowing,
they are not malfunctions.
from the air outlet vent.
In COOL mode, sometimes the mist emitted
When the indoor temperature and humidity are
very high, this phenomenon would happen. This
is caused by the room air is swiftly cooled down.
After running for a while, indoor temperature and
humidity will fall down, the mist will die away.
Creaking noise can be heard when start or stop
the unit.
This is caused by the deformation of plastic due
to the changes of temperature.
waitting

ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
Troubleshooting
Phenomenon
The unit can not run
Break off
Troubleshooting
Has the power been shut down? Is the circuit protection device tripped off or not? Is voltage higher or lower? (Tested by professionals)
Is the Timer correctly used?
Cooling(Heating) efficiency is not good.
Is Temp. setting suitable? Were inlet and outlet vents obstructed? Is filter dirty? Are the windows and doors clothed? Did Fan speed set at low speed? Is there any heat sources in the room?
Wireless remote control is not available
The unit is interfered by abnormal or frequent functions switchover occasionally the controller cannot operate. At this time, you need to pull out of the plug, and reinsert it.
Is it in its receiving range? Or obstructed? To check the voltage in wireless remote control
batteries.
inside is charged, otherwise to replace the
Whether the wireless remote control is damaged.
If water leakage in the room
The air humidity is on the high side. Condensing water over flowed. The connection position of indoor unit drainage
pipe is loosed.
If water leakage in outdoor unit
When the unit is running in COOL mode, the
due to the water cooled down.
pipe and connection of pipe would be condensed
When the unit is running in Auto Defrosting mode,
the ice thawed and flowed out.
When the unit is running in HEAT mode, the
water adhered on heat exchanger dripped off.
Noise from indoor unit emitted.
The sound of fan or compressor relay is switching
on or off.
When the defrosting is started or stop running,
it will sound. That is due to the refrigerant flowed to the reverse direction.

ƽ
ƽ
ƽ
Ʒ
Ʒ Ʒ
Ʒ
Ʒ
Ʒ
Troubleshooting
Phenomenon
Moisture on air outlet vent
Troubleshooting
In HEAT mode, when the temperature of indoor heat exchanger is very low, that will stop deliver air in order to prevent blowing cool air. In HEAT mode, when the outdoor temperature is low or high humidity, there are much frost be formed on the outdoor heat exchanger, that the unit will automatically defrost, indoor unit stop blowing air for 8-10min. During the
In dehumidifying mode, sometimes indoor fan
will stop, in order to avoid condensing water be
vaporized again, restrain temperature rising.
defrosting, there is water flowing out or vapor be produced.
Indoor unit cannot deliver air
If unit is running under the high humidity for a long
outlet grill and drip off.
time, the moisture will be condensed on the air
Immediately stop all operations and plug out, contact the dealer in following situations.
There is harsh sound during operation
The terrible odors emitted during operation
Water is leaking in the room
Air switch or protection switch often breaks
Carelessly splash water or something into air conditioner
There is an abnormal heat in power supply cord and power plug.
Stop running and pull out of the plug.









 

 




ƽ
ƽ
ƽ ƽ ƽ
ƽ

 
Installation service- Notices for installation
Important Notices
The unit installation work must be done by qualified personnel according to the local rules and this manual.
Before installating, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may not solved, due to discommodious contacts. When removing the unit to the other place, please firstly contact with the authorized
GREE Maintenance Center in the local area.
Basic Requirements For Installation Position
Install in the following place may cause malfunction. If it is unavoidable contact with service center please:
Place where strong heat sources, vapors, flammable gas or volatile object are emitted. Place where high-frequency waves are generated by radio equipment, welders and
medical equipment.
Place where a lot of salinities such as coast exists. Place where the oil (machine oil) is contained in the air.
Place where a sulfured gas such as the hot spring zones is generated. Other place with special circumstance.
Indoor Unit Installation Position Selection
The air inlet and outlet vent should be far from the obstruction, make sure that the air
can be blown through the whole room.
Select a position where the condensing water can be easily drained out, and the place is easily connected for outdoor unit. Select a location where the children can not reach.
Can select the place where is strong enough to withstand the full weight and vibration of the unit. And will not increase the noise. Be sure to leave enough space to allow access for routine maintenance. The height of the installed location should be 230cm or more from the floor. Select a place about 1m or more away from TVset or any other electric appliances. Select a place where the filter can be easily taken out.
Make sure that the indoor unit installation should accord with installation dimension
diagram requirements.
Outdoor Unit Installation Position Selection
Select a location from which noise and outflow air emitted by unit will not inconvenience neighbors, animals, plants.
Select a location where there should be sufficient ventilation. Select a location where there should be no obstructions cover the inlet and outlet vent.
The location should be able to withstand the full weight and vibration of the outdoor unit and permit safe installation. Select a dry place, but do not expose under the direct sunlight or strong wind.
Make sure that the outdoor unit installation dimension should accord with installation
dimension diagram, convenient for maintenance, repair.
The height difference of connecting the tubing within 5m, the length of connecting the
tubing within 10m.
Select a place where it is out of reach for the children.
Select a place where will not block the passage and do not influence the city appearance.

Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool.

A air switch having a contact separation of at least 3mm in all poles should be fixed in fixed wiring.





ƽ
ƽ
ƽ
Notices for installation
Earthing requirements
Air conditioner is type I electric appliance, thus please do conduct reliable earthing measure.
The yellow-green two-color wire in air conditioner is earthing wire and cannot be used
for other propose. It cannot be cut off and be fix it by screw, otherwise it would cause
electric shock. The user power must offer the reliable earthing terminal. Please don't connect the earthing wire with the following place:
ķTap water pipe ĸGas pipe ĹContamination pipe
ĺOther places that professional personnel consider them unreliable.
Note:
It should be reliably earthed, and it should be connected to the special earth device,
the installation work should be operated by the professional. The air switch must have the functions of magnetic tripping and heat tripping, in order
to protect the short circuit and overloading.
The min. distance from the unit and combustive surface is 1.5m.
In the family, the live wire, neutral wire in the power supply
wrong connection may cause fire.
socket that should be connected as the right figure, position
cannot be wrong connected, and should reliably connected,
there should be not short circuit in the inside.



Safety Requirements For Electric Appliances
The power supply should be used the rated voltage and AC exclusive circuit,
the power cable diameter should be satisfied.
Voltage applying range: the normal running range is rated voltage 90%-110%.
Don't drag the power cable emphatically.

Installation dimension diagram
Space to the ceiling
Space to the wall
Space to the floor
Air outlet side
Space to the wall
Space to the obstruction
Air inlet side
Space to the wall
Air outlet side
Space to the wall
Above
Above
Above
Above
Above
Above
Installation dimension diagram
Above
Above
Above
Above
¶PP
¶PP
Ø

Install the rear panel
1. Always mount the rear panel horizontally. As the water drainage pipe at the left, when adjusting the rear panel, this side should not be too high; the right side should be slightly high.
Fix the rear panel on the selected
location.
Be sure that the rear panel has
been fixed firmly enough to withstand
the weight of an adult of 60kg, furthermore, the weight should be evenly shared by each screw.
Mark on the middle of it
Gradienter
Wall
Wall
Space to the wall 150mm above
Space to the wall
150mm
above
Left
Right
(Rear piping hole)
(Rear piping hole)
Install the piping hole
1ˊMake the piping hole˄ï65˅in the wall at a slight downward
slant to the outdoor side. At Fig.6.
2ˊ
Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Indoor
Outdoor
Wall
pipe
Seal pad
Protection
sleeve pipe
Install the water drainage pipe
ˊFor well draining, the drain hose should be
placed at a downward slant. Do not wrench or bend the drain hose or flood its end by water.
2ˊ
3
ˊ
When the long drainage hose passing through indoor, should wrap
the insulation materials.
Wrenched
Bent
Flooded
Connect indoor and outdoor electric wires
1ˊOpen the front panel upwardly.
2ˊScrew off the fixing screw of cover plate
and screw off cover plate (As show in Fig. 7)
3ˊ
Put the power connection cable through the back of indoor unit wire hole and take it out
4ˊ
Connect the blue
wire of powe
r
connection
cord to the terminal on “N”, the black one to
“2”,the b
rown one toĀ3ā,the yellow-green
one (earth wire) to “ ” (As shown in Fig. 8)
5ˊ
Put the power connection cable the section,
which with sheath into wire groove, and cover the cover plate, screw on the fixing screw tighten the connection wire.
6ˊCover the front panel cover.
Power
connection
wire
Wire terminal cover plate
Fig.7
Fig. 8
Power connection wire
Terminal board
Blue
Black
Yellow-green
Install indoor unit
Fig.6
Brown
18

ƽ
ƽ ƽ
ƽ ƽ
ƽ

Ł ł





Ï
Ï
Ï



Install indoor unit
NOTE:
When connecting the electric wire if the wire length is not enough, please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed.
The electric wiring must be correctly connected, wrong connection may cause spare parts malfunction.
Tighten the terminal screw in order to prevent loose. After tighten the screw, slightly pull the wire and confirm whether is it firm or not. If the earth wire is wrong connection, that may cause electric shock.
The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that
the dust, moisture may enter in or the connection terminal will be affected by outside force,
and will cause fire or elelctric shock.
Install the indoor uni t
The piping can be lead out from right, right rear, left, left rear. When routing the piping and wiring from the left
or right side of indoor unit, cut off the tailings from the chassis in necessary (show in Fig.9).
Cut off the tailings 1 when routing the wiring only;
Cut off the tailings 1 and tailings 2 when routing both the wiring and piping.
Take out the piping from body case, wrap the piping
electric wire, water pipe with tape and put them th­rough the piping hole (As show in Fig.10)
Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm
enough. (As show in Fig.11) The height of the installed location should be 2.3m
or more from the floor.
Install the connection pip e
Align the center of the piping flare with the relevant valve.
Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to the following.
Tightening torque table
Hex nut diameter Tightening torque table(N.m)
NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention to the piping bending, do not damage the connection pipe; the joint nut couldn't tighten too
much, otherwise it may cause leakage.
Tailing 2
Tailing 1
Fig.9
Fig.10
Fig.11
Right
Right nether
Right rear
Left
Left rear
Mounting board
Mounting
board
Fixing hook
Gas side piping
External connection
electric wire
Liquid side
piping
Gas side piping
Finally wrap it with tape
Water drainage pipe
Liquid side
piping
insulation
Indoor unit piping
Taper nut Piping
Torque wrenchSpanner
insulation

Install outdoor unit


 
ƽ
ƽ
A i r p u r g i n g a n d l e a k ag e t es t

Take out the nut cover of the inlet for refrigerant.

Align the center of the piping and tighten the conical nut with hands.

To tighten the conical nut with spanner.

Take off the valve cover of liquid valve and gas valve and nut of Freon charge nuzzle.

Loosen the valve stem of liquid valve with a hex wrench. Push the check valve core of
gas valve to discharge air and moisture remaining in refrigerant system.

After 15seconds, stop pushing the valve core as soon as the
refrigerant starts to be discharged, and reinstall the service port nut.

Open the stem of liquid valve and gas valve completely. (As show in Fig. 12)

Tighten the valve cover, use the soap water or leakage detector to test,
the outdoor unit and pipeline connection leak or not.

If possible, adopt vacuum pump vacuum the air from the gas stem.
(As show in Fig.13)
Ou t do or c on den s at i on d r ai n ag e ( H e a t p u m p t y p e o nl y )
When the unit is heating, the condensing water
and defrosting water can be drained out reliably
Installation: Install the outdoor drain elbow in 25
hole on the base plate,and joint the drain hose to the
elbow, so that the waste water formed in the outdoor
Ø
Valve cap
JDXJH
9DFXXPSXPS
Liquid pipe
Gas pipe
)LJ
)LJ
Chassis
Outdoor drain elbow
through the drain hose.
*DVSLSH
/LTXLGSLSH
/LTXLGYDOYH
+H[DJRQ
*DVYDOYH
Freon charge nuzzle
Screwdriver
,QGRRUXQLWWHUPLQDOERDUG
2XWGRRUXQLWWHUPLQDOERDUG
wire
leakage test
%OXH
<HOORZJUHHQ
Diagram for cooling
and hea
ting unit
%ODFN
%URZQ
EElleeccttrriicc wwiirriinng
g
(1pc screw)

Disassemble the handle on the outdoor unit right side plate.
Take off wire clamp. Connect and fix power connect cord to
terminal of line bank. Wiring should fit that of indoor unit.
Fix the power connection cable with wire clamp, for cooling
and heating unit, then use the wire clamp to fix the signal
control wire, then connect the corresponding connector.
Ensure wire has been fixed well.
Install the handle. (1 screw to fix)
NNoottee:
:
Wrong wiring may cause spare parts
malfunction.
After the cable fixed, make sure there should be a free space between the connection and fixing place on the
lead wire.
Connection diagram of indoor unit and outdoor unit:
unit can be drained out to a proper plate.
9DFXXP
Air purging and
Power connection
,QGRRUXQLWWHUPLQDOERDUG
wire
%OXH
<HOORZJUHHQ
%ODFN
%URZQ
Power connection
2XWGRRUXQLWWHUPLQDOERDUG
Diagram for cooling
only unit
%URZQ
%OXH
%ODFN
<HOORZJUHHQ
3RZHUFRQQHFWLRQZLUH
The signal control wire is only
:LUHFODPS
fit for cooling and heating unit


   

 
Check after installation and test operation
Check after installation
Items to be checked
Possible malfunction
Has it been fixed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
It may cause insufficient cooling(heating) capacity.
Is heat insulation sufficient? It may cause condensation and dripping.
Is water drainage well?
It may cause condensation and dripping.
Is the voltage in accordance with the rated
voltage marked on the nameplate?
It may cause electric malfunction
or damage the part..
Is the electric wiring and piping connection installed correctly and securely?
It may cause electric malfunction
or damage the part.
Has the unit been connected to a secure earth connection?
It may cause electrical leakage.
Is the power cord specified?
It may cause electric malfunction
or damage the part
Is the inlet and outlet been covered?
It may cause insufficient cooling(heating) capacity.
Has the length of connection pipes and refrigerant capacity been recorded?
The refrigerant capacity is not accurate.
Test Operation
Before test operation
Do not switch on power before installation isfinished completely.
Electric wiring must be connected correctly and securely. Cut-off valves of the connection pipes should be opened.
All the impurities such as scraps and thrums must be cleared from the unit.
Test operat io n m eth od
Switch on power, press "ON/OFF" button on the wireless remote control to start the operation.
Press MODE button, to select the COOL, HEAT, FAN to check whether the operation is normal or not.

Fig. a
Installation Instructions
1. Forcibly pull the panel for a specific angle
from the two ends of the front panel according
to the arrow direction. Then pull the air filter
2. Mount the healthy filter onto the air filter,(as
shown in Fig.b). If the air filter cannot be in-
stalled, please mount the healthy filter on
3. Mount the air filter properly along the arrow
direction in Fig.d, and then close the panel cover.
ion filter can't be cleaned with water, while active carbon, photocatalyst,
low temperature conversion (LTC) catalyst, formaldehyde eliminator, ca-
The healthy filter commonly has its usage lifetime for one year under
normal condition. As for silver ion filter, it is invalid when its surface becomes
according to the installation instruction. Pay special attention to that silver
Take out the healthy filter before cleaning and reinstall it after cleaning
Installation and Maintenance of Healthy Filter
Cleaning and Maintenance
Service Life
ƽ
Healthy filter
Air filter
Healthy filter
downwards to remove it. (See Fig.a)
the front case. (as shown in Fig.c).
Fig. b
Fig. c
Fig. d
techin or mite killing filter can, but can't with brush or hard things. Dry it in
the shade or sun after cleaning, but not by wiping.
black (green).
goods, the latter one shall prevail. The quantity of healthy filters shall be
based on the actual delivery.
This supplementary instruction is provided for reference to the unit with
healthy filter. If the graphics provided herein is different from the physical
Climate Control Warranty Card
‘Comfort At Your Fingertips’
NOTE: MACHINES MUST BE SERVICED ANNUALLY CONTACT DISTRIBUTOR TO ARRANGE A LICENSED CONTRACTOR.
This Warranty applies to Domestic products
purchased and installed in Australia.
The Trade Practices Act, 1974 and other State and Territory Laws having a similar purpose imply certain terms and rights for the Owner’s benefit into the contract by which the Equipment is purchased. If this Advanced Group Australia P/L 5 Year Warranty is inconsistent with any such terms or rights, it will restrict or modify those terms or rights (which in this Warranty are called the “Owner’s Statutory Rights”) only to the extent permitted by law.
THE RIGHTS GIVEN BY ADVANCED GROUP AUSTRALIA P/L 5 YEAR WARRANTY IS IN ADDITION TO THE OWNER’S STATUTORY RIGHTS
The Climate Control equipment listed on the back of this card is warranted by Advanced Group Australia Pty Limited, against defects in design, materials and workmanship for a period of 5 years from the date the equipment is purchased by the original owner for domestic use, and 2 years from the date the equipment is purchased by the original owner for commercial use. Equipment defects covered by this Warranty will be repaired or replaced at the discretion of Advanced Group Australia P/L without cost to the owner for parts or direct repair labour. The repair or replacement shall be performed during normal business hours by Advanced Group Australia P/L or a repair agent authorised by Advanced Group Australia P/L. Any Climate Control parts or Climate Control equipment replaced under this Warranty will be warranted in accordance with the provisions of this Warranty for the remainder of the original warranty period or 12 months from the completion of the repair, whichever is the greater. Except where inconsistent with the Owner’s Statutory Rights and the rights given by this Warranty, all other warranties and all liability of Advanced Group Australia P/L for any loss or damage direct and consequential is expressly excluded.
This Warranty DOES NOT cover:­a) Damage or problems or unsatisfactory performance caused to the equipment by faulty or incorrect external electrical wiring, incorrect power supply, voltage fluctuations, over voltage transients or electromagnetic interference not originating within the equipment. b) Damage or problems resulting from incorrect or poor installation, including the failure to properly evacuate the air conditioning system and the use of an un-licensed contractor. c) Damage or problems caused by the use of an accessory, component or equipment not supplied by Advanced Group Australia P/L and is not part of the original Climate Control Air conditioner. d) Damage or problems caused by storm, fire, flood, vandalism, misuse, negligence, Acts of God, earthquake, war, vermin, foreign matter entering the equipment (eg dirt and moisture) or any other outside agency.
e) Damage or deterioration to the external surfaces or refrigeration coils caused by normal weathering or corrosive atmospheric conditions.
f) Any costs or additional labour associated with gaining acceptable service access to equipment installed in restricted or unsafe (eg high) locations. g) Freight charges (including insurance) or travelling cost for repairs performed outside the area normally serviced by Advanced Group Australia P/L or a repair agent authorised by Advanced Group Australia P/L h) Equipment which has been installed in a transportable or mobile application (eg caravan or boat). i) Equipment which has been re-installed at a location other than the original location. j) Any consumable item (eg batteries, filters, belts) supplied with the equipment unless the item is shown to be defective at the time of purchase. k) Damage or problems or unsatisfactory performance resulting from operation in an environment where the climatic comfort of humans is not the primary function of the equipment. l) Damage or problems or unsatisfactory performance resulting from operation at conditions outside the operating conditions specified in the Advanced Group Australia P/L technical or sales literature applicable to the Climate Control equipment. m) Damage, problems or unsatisfactory performance resulting from misapplication of the equipment.
Owner’s Responsibility The owner is responsible for the correct operation and regular maintenance of the equipment as listed below. The correction of any non product fault or problem is not covered by this warranty. a) Operation and maintenance of the equipment in accordance with the operating instructions. b) Regular cleaning of the air filter(s) and replacement where necessary. c) Ensuring that the air inlet and outlet on the outdoor unit is kept clear of any obstructions (eg dirt, leaves, plants) d) Ensuring that the condensate drain is kept clean. e) Replacement of exhausted batteries. f) The application of additional corrosion protection if the product is installed in a corrosive environment (eg Industrial pol
lution, sea air).
Owner’s Statutory Rights In respect of any goods supplied under the contract which are not of a kind ordinarily acquired for personal domestic or household use or consumption, unless the owner establishes the following limitation of liability would not be fair and reasonable, the liability of Advanced Group Australia P/L for any defect of design, materials or workmanship will be limited to any of the following as determined by Advanced Group Australia P/L:­a) Replacing the equipment or supplying equivalent equipment; b) Repairing the equipment; c) Paying the cost of replacing the equipment or acquiring equivalent equipment; d) Paying the cost of having the equipment repaired.
Please complete the details below and store this card along with the purchase docket in a safe place. To receive repair under W
arranty both this card and the purchase docket must be presented:
Outdoor Unit Model No............................................................................................ Serial No………………………………………………………………………………...
Indoor Unit(s) Model No........................................................................................... Serial No………………………………………………………………………………..
Model No……………………………………………………………………………Serial No……………………………………………………………………………….. Model No……………………………………………………………………………Serial No……………………………………………………………………………….. Model No……………………………………………………………………………Serial No……………………………………………………………………………….. Controller(s) Model No……………
Supplied by . . . . . . . . . . . . . . . . . . . . Phone No. . . . . . . . . . . . . . . . . . . . . . . . . . .
Installed by . . . . . . . . . . . . . . . . . . . . Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Owner’s Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Note: For repair of equipment under this Warranty it is recommended that the owner contact their Climate Control Dealer / and or their licensed Installer. If the owner requests Advanced Group Australia P/L to perform or arrange the service call, the owner will be liable for all associated costs if the problem is not covered by the provisions of this Warranty.
ADVANCED GROUP AUSTRALIA P/L 47 Railway St Yennora NSW 2161 +61 2 9632 9441