Air
Dehumidification
System
CLI-DH20-E | Installation & Operating Instructions
Congratulations on your purchase of a
Cli~Mate Air Dehumidification System.
This air dehumidifier is compact and stylish in design, quiet, portable and easy to operate. Unit effectively removes moisture
from the air creating a drier, healthier room environment.
Note: Please read through the instructions carefully before using or installing the product and ensure that the
manual is kept in a safe place for future reference.
The system must be properly installed and located in accordance with the installation instructions before it is used.
During the set up of this product if you have any questions / comments / issues DO NOT RETURN TO STORE.
FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT, FREE CALL 1300 764 325.
CUSTOMER HOTLINE: 1300 764 325
Register your warranty online at www.aquaport.com.au/warranty
Aquaport Corporation Pty Ltd
PO Box 81 Findon SA 5023 Australia
Telephone: 1300 764 325
Facsimile: 08 8354 0722
Email: aquaport@aquaport.com.au
Web: www.aquaport.com.au
Electrical Requirements:
Australia / New Zealand 240V / 230V 50Hz
Due to manufacturing alterations product may
vary slightly from the pictured.
SPECIAL PRODUCT INSTRUCTIONS
This appliance is designed for household use only.
Do not use this unit outdoors, in wet environments or on
wet surfaces.
To achieve best performance; make sure all doors and windows
are closed before turning on the unit.
The appliance air vents and air grilles must not be obstructed at
any time. Air flow is required for the unit to operate
effectively. Place unit in a flat location at least
30cm from wall or other appliances.
Units must be placed on a stable flat surface to reduce possible
excessive vibration and noise.
Units must never be placed and operated on an angle as water
spillage from reser voir can occur.
Empty the water when water reservoir is full or not in use for a
prolonged period.
Recommended operating temperature range is minimum 5°C
(RH 40%) and maximum 35˚C (RH 90%).
Any servicing other than cleaning and user maintenance will violate
the terms of this WARRANTY and warranty will be null and void.
PRODUCT SPECIFICATIONS
Air Dehumidifier Specifications
System Specifications CLI-DH20-E
Air Dehumidification System
Dehumidification 20 Litres/day
Dehumidifying Capacity 0.83 kg/hour
Air Circulation 140 cbm/hour
Power Consumption 340 watts
Capacity of Water Tank 3.8 L
Refrigerant R134a (150 g)
Noise Level ≤46dB
N.W 12.8 kgs
G.W 14.0 kgs
Product Dimensions 350 x 242 x 586 mm
Note:
RH = Relative Humidity
INSTALLATION AND OPERATING INSTRUCTIONS 1
OPERATION CONDITIONS AND SAFETY PRECAUTIONS
Read all instructions carefully.
• All components need to be installed in accordance with the user
manual instructions for correct performance of unit.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensor y or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the appliance.
• A power outlet is required to operate the appliance. Electrical
supply required 220~240V/50Hz.
• Ensure unit is properly grounded.
• To protect against re, electric shock and personal injur y, do
not spray water onto the unit, do not immerse cord, plugs, or
appliance in water or other liquid. Do not push any objects in the
unit air inlet and air outlet exhaust grilles.
• Unplug from outlet when not in use and before cleaning. Never
unplug unit with wet hands.
• Do not operate any appliance with a damaged cord or plug or
after the appliance malfunctions, or has been damaged in any
manner.
• If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
• The use of accessory attachments not recommended by the
appliance manufacturer may result in fire, electric shock or
personal injury.
• Ventilation – The appliance air vents and exhaust grilles must
not be obstructed at any time. Air flow is required for the unit to
operate effectively. Place unit in a flat well-ventilated location at
least 30 cm from wall or other appliances.
• Do not use outdoors.
• Do not use in wet environments e.g. Bathrooms or Showers.
• Do not let cord hang over edge of table or counter, or touch hot
surfaces.
• Do not use appliance for other than intended use.
• This appliance should always be used in conjunction with a
safety switch.
• Do not place the unit near an oven, heater, radiator, direct
sunlight or any other heat source.
• Do not use unit near ammables or re.
• Ensure unit is on a stable and even at surface to prevent unit
from falling or tipping over and to reduce possible excessive
vibration and noise.
2 INSTALLATION AND OPERATING INSTRUCTIONS
• If unit ever tips or falls over when water reservoir is full,
immediately unplug the power cord. Ensure unit is dried
thoroughly before operation of the unit.
• Do not put ngers or other objects in any openings of the unit.
During the set up of this product if you have any
questions / comments / issues DO NOT RETURN TO STORE
FOR SERVICE AND TECHNICAL ADVICE ON THIS PRODUCT FREE
CALL 1300 764 325
INSTALLATION AND OPERATING INSTRUCTIONS 3