PRESSURE STEAMERS
PRESSURE STEAMERS
2 OR 3 COMPARTMENTS
STEAM COIL GENERATOR
36” WIDE CABINET BASE
Cleveland Standard Features
n 5
psi Operating Pressure in cooking compartments
n
M
echanical interlock prevents unlatching door while compartment
is pressurized
n Timers, one per compartment, are mechanical style with
audible signal
n Thermostatic Trap vents cooking compartment automatically
n Steam Inlet Valves and Exhaust Valves interlocked for
synchronous action
n 8 psi Compartment Safety Valve
n Capacity per compartment for eight, 12” x 20” x 2 1/2” deep
Cafeteria Pans, or four, 18” x 26” Bun Pans
n Heavy Duty, free floating, cast aluminum compartment doors
n Compartment Door Hinges have adjustable hinge pins and
self-lubricating bushings
n Door Gasket replaceable without tools
n Pressure Gauge for compartment Operating Pressure
n Compartment Slide Racks are removable without tools, for
easy cleaning
n Type 430 Stainless Steel: external enclosure, Table Top and
eight gauge plate cooking compartments
n Modular Cabinet Base with Hinged Doors
n High efficiency Electric Steam Generator with Automatic
ater Fill on start-up
W
n Automatic W
Cut-of
n Steam Generator equipped with High-limit Pressure Safety
ater Level Control System with Low W
f Circuit
Switch and Safety Valve
n
Automatic Steam Generator (boiler) Blowdown allows intermittent
control, complete with additional Manual Drain Valve
n Single cold water Connection (no hot water required)
n 6” Stainless Steel Legs with level adjustment and flanged feet
p Secondary Low Water Cut-Off, factory installed (CALS)
AR. CA. CO. CT
(Required for
MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash.
DC)
n Standard Voltage for Controls, 115 volts, 60 Hz, single phase
n All major components are serviceable from the front of unit
AZ.
. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
ater Power
MODELS:
2 Compartments 3 Compartments
c PSM-2 c PSM-3
t Form Specifications
Shor
Shall be _____ Compartments, CLEVELAND, Pressure Steamer,
Model PSM- _____ , Steam Coil Steam Generator, _____ volts, single
phase. Each Cooking Compartment equipped with: 60 Minute Timer;
Pressure Safety Valve: Heavy-duty, free floating Door with Safety
Interlock; and synchronous operating Steam Inlet and Exhaust/Drain
Valves. Solid State Controls operate Water Level and Steam
Generator (boiler) Safety Functions. Automatic Steam Generator
(boiler) Blowdown with additional Manual Drain V
p Pressure Reducing Valve for 50 to 120 psi steam pressure
V)
(PR
p Moisture Separator for steam supply (MS)
p Stainless Steel base Frame (FSS)
p Special Compartment Slide Racks
p 12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep
p Intermediate Pull-Out Shelf (POS)
p Spray Head with flexible Hose (SH)
p Water Filters
p Rear Gas Connection (RGT)
alve.
Options & Accessories
p Automatic Steam Inlet and Exhaust Operation (AT-2):
includes 60 minute
Automatic
imers and Manual Bypass
T
SECT. VI PAGE 5
0707
Each compartment has capacity for:
•
Eight, 12˝ x 20˝ x 2
1
⁄2˝ Cafeteria Pans or
Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or
Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or
Four, 18˝ x 26˝ Bun Pans
Many regional, state and local codes exist and it is
•
the responsibility of the owner and installer to comply with those codes.
Cleveland Range equipment is built to comply with
•
applicable standards for manufacturers. Included
among those approval agencies are: UL, ULC,
CSA and NSF.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be
necessary. The fact that a water supply is potable is not
proof that it will be suitable for the generator.
, and a Daily Blowdown, are as follows:
less than 30 parts per million
Condensate Return Drain Line
Do not use PVC pipe for
drain.
Cleveland Range reserves right of design improvement or modification, as warranted.
3/4” IPS. Do not connect to common drain.
100 watts
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoining wall or equipment is over
30” high for service access)
Contact factor
variances to clearances.
or
y f
SECT
(NOT
.
VI P
Litho in U
TO SCALE)
AGE
0707
.S.A.
6