PRESSURE STEAMERS
PRESSURE STEAMERS
2 OR 3 COMPARTMENTS, GAS FIRED STEAM GENERATOR 200 OR 300M BTU, 36” WIDE CABINET BASE with NICKELGUARD™
Cleveland Standard Features
I
I
5 psi Operating Pressure in cooking compartments
II
Mechanical interlock prevents unlatching door while compartment is pressurized
II
Timers, one per compartment, are mechanical style with audible signal
I
I
Thermostatic Trap vents cooking compartment automatically
II
Steam Inlet Valves and Exhaust Valves interlocked for synchronous action
II
8 psi Compartment Safety Valve
II
Capacity per compartment for eight, 12” x 20” x 2 1/2” deep Cafeteria Pans, or four, 18” x 26” Bun Pans
II
Heavy Duty, free floating, cast aluminum compartment doors
II
Compartment Door Hinges have adjustable hinge pins and self-lubricating bushings
II
Door Gasket replaceable without tools
II
Pressure Gauge for compartment Operating Pressure
II
Compartment Slide Racks are removable without tools, for easy cleaning
II
Type 430 Stainless Steel: external enclosure, Table Top and eight gauge plate cooking compartments
II
Modular Cabinet Base with Hinged Doors
II
High efficiency Gas-Fired Steam Generator with NickelGard and Automatic Water Fill on start-up
II
Automatic Water Level Control System with Low Water Power Cut-off Circuit
II
Steam Generator equipped with High-limit Pressure Safety Switch and Safety Valve
II
Automatic Steam Generator (boiler) Blowdown allows intermittent control, complete with additional Manual Drain Valve
II
Steam Generator with Electronic Spark Ignition
II
Single Cold Water Connection (no hot water required)
II
6” Stainless Steel Legs with level adjustment and flanged feet
II
Gas Pressure Regulator and Control Valve
II
Standard Voltage 115 volts, 60 hz, single phase
II
All Major Components are serviceable from the front of unit
Options & Accessories
Ë Automatic Steam Inlet and Exhaust Operation (AT-2):
includes 60 minute Automatic Timers and Manual Bypass
Ë 15 psi for Kettle Operation, includes Power Take-Off (PTO) Ë Kettle Interconnecting Kit (IMK) Ë Stainless Steel Insulated Flue (SSF)
Compartments 3 Compartments
MODELS:
2
PGM-200-2 PGM-200-3PGM-300-2 PGM-300-3
Short Form Specifications
Shall be _____ Compartments, CLEVELAND, Pressure Steamer, Model PGM- _____ - _____ , Gas-fired Steam Generator, _____ M BTU input; _____ volts, single phase. Each Cooking Compartment equipped with: 60 Minute Timer; Pressure Safety Valve; Heavy-duty, free floating Door with Safety Interlock; and synchronous operating Steam Inlet and Exhaust/Drain Valves. Solid State Controls operate Water Level and Steam Generator (boiler) Safety Functions. Automatic Steam Generator (boiler) Blowdown with additional Manual Drain Valve.
Ë Special Compartment Slide Racks Ë Stainless Steel base Frame (FSS) Ë 12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep Ë Intermediate Pull-Out Shelf (POS) Ë Spray Head with flexible Hose (SH) Ë Gas Option, other than natural Ë Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
Ë Water Filters
Ë Rear Gas Connection (RGT)
Ë Correctional Packages
SECT. VI PAGE 3
1007
Each compartment has capacity for:
Eight, 12˝ x 20˝ x 2
1
2˝ Cafeteria Pans or Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or Four, 18˝ x 26˝ Bun Pans
Many regional, state and local codes exist and it is
the responsibility of the owner and installer to com­ply with those codes.
Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included among those approval agencies are: ASME/N.Bd., NSF, CSA (AGA, CGA).
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
The Floor Drain must be located outside the con­fines of the equipment.
1 1/2” IPS common drain.
5.0 Amps
** Do not connect to GFI outlet. See note below.
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA (AGA, CGA).
Do not connect other units to this drain.
Do not use PVC pipe for drain.
Right - 6”, Left - 6”, Rear - 6” (12” on control side if adjoining
wall or equipment is over 30” high for service access)
For use in non­combustible locations.
Contact factory for variances to clearances.
(NOT TO SCALE)