PRESSURE STEAMERS
PRESSURE STEAMERS
2 OR 3 COMPARTMENTS, CABINET MOUNTED
ELECTRIC STEAM GENERATOR
24, 36 OR 48 KW, 36” WIDE CABINET BASE
Cleveland Standard Features
n 5
psi Operating Pressure in cooking compartments
n
Mechanical interlock prevents unlatching door while compartment
is pressurized
n Timers, one per compartment, are mechanical style with
audible signal
n Thermostatic Trap vents cooking compartment automatically
n Steam Inlet Valves and Exhaust Valves interlocked for
synchronous action
n 8 psi Compartment Safety V
n Capacity per compartment for eight, 12” x 20” x 2 1/2” deep
Cafeteria Pans, or four, 18” x 26” Bun Pans
n Heavy Duty, free floating, cast aluminum compartment doors
n Compartment Door Hinges have adjustable hinge pins and
self-lubricating bushings
n Door Gasket replaceable without tools
n Pressure Gauge for compartment operating pressure
n Compartment Slide Racks are removable without tools, for
easy cleaning
n Type 430 Stainless Steel: external enclosure, Table Top and
eight gage plate cooking compartments
n Modular Cabinet Base with Hinged Doors
n High efficiency Electric Steam Generator with Automatic
Water Fill on start-up
n Automatic W
Cut-of
n Steam Generator equipped with High-limit Pressure Safety
ater Level Control System with Low Water Power
f Circuit
Switch and Safety Valve
n
Automatic Steam Generator (boiler) Blowdown allows intermittent
control, complete with additional Manual Drain Valve
n Steam Generator Pressure Gauge
n 6” Stainless Steel Legs with level adjustment and flanged feet
n Single Cold W
ater Connection (no hot water required)
p Secondary Low Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
MT
DC)
n Standard Voltage 208-240 volts, 60 hz, single phase, three
. NM. NC. OK. OR. PR. RI.
. NE. NV
wire
n All Major Components are serviceable from the front of unit
Options & Accessories
alve
TN. UT
A. WV., Buffalo, NY, Wash.
A. W
. V
MODELS:
2 Compartments 3 Compartments
c PEM-24-2 c PEM-24-3
c PEM-36-2 c PEM-36-3
c PEM-48-2 c PEM-48-3
Short Form Specifications
Shall be _____ Compartments, CLEVELAND, Pressure Steamer, Model
PEM- _____ - _____ , Electric Steam Generator, _____ kw,
_____volts, _____ ph, three wire. Each Cooking Compartment equipped
with: 60 Minute Timer; Heavy-duty, free floating Door with Safety
Interlock; and synchronous operating Steam Inlet and Exhaust/Drain
Valves. Solid State Controls operate Water Level and Steam
Generator (boiler) Safety Functions. Automatic Steam Generator (boiler) Blowdown with additional Manual Drain Valve.
p 15 psi for Kettle Operation, includes Power
p Kettle Interconnecting Kit (IMK)
p Stainless Steel base Frame (FSS)
p Stainless Steel gas flue cover, insulated (SSF)
p Special compartment Slide Racks
p 12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep
p Intermediate Pull-Out Shelf (POS)
p Spray Head with flexible Hose (SH)
oltages, other than standard
p V
p Water Filters
p Correctional Packages
Take-Off (PTO)
p Automatic Steam Inlet and Exhaust Operation (AT-2):
includes 60 minute Automatic Timers and Manual Bypass
SECT. VI PAGE 1
0707
Each compartment has capacity for:
•
Eight, 12˝ x 20˝ x 2
1
⁄2˝ Cafeteria Pans or
Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or
Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or
Four, 18˝ x 26˝ Bun Pans
Many regional, state and local codes exist and it is
•
the responsibility of the owner and installer to comply with those codes.
Cleveland Range equipment is built to comply with
•
applicable standards for manufacturers. Included
among those approval agencies are: UL, NSF,
ASME/N.Bd., CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be
necessary
proof that it will be suitable for the generator.
The fact that a water supply is potable is not
.
ELECTRIC
KW Volts Watts Ph Amps Wire
103.4 2
1
24 208
Cleveland Range reserves right of design improvement or modification, as warranted.
21,500
220 24,000 1 109.1 2
240 24,000 1 100.0 2
1 45.9 2
20,200
440
480 24,000 1 50.0 2
208 21,500 3 59.7 3
63.1 3
3
24,000
220
240 24,000 3 57.8 3
440 20,200 3 26.5 3
28.9
3
24,000
480
600 24,000 3 23.1 3
360 21,500 3 34.5 4
36.5 4
3
24,000
380
415 24,000 3 33.4 4
3
KW Volts Watts Ph Amps Wire
36 208 32,200 3 89.5 3
48 208
36,000 3 94.6 3
220
240 36,000 3 86.7 3
440
480
600 36,000 3 34.7 3
360 32,200 3 51.7 4
380 36,000 3 54.8 4
415 36,000 3 50.1 4
220 48,000 3 126.1 3
240
440 40,300 3 52.9 3
480 48,000 3 57.8 3
600 48,000 3 46.2 3
360 42,900 3 68.9 4
380
415
30,200
36,000
42,900
48,000
48,000
48,000
3
3
3 119.2 3
3
3
3
39.7 3
43.4
15.6
1
73.0 4
66.9 4
WATER DRAINAGE CLEARANCE
1/4˝ NPT
Cold Water Inlet
35 psi minimum
60 psi maximum
3
3
The Floor Drain must be located
outside the confines of the
equipment base
.S. common drain.
1 1/2˝ I.P
Do not connect other units to this
drain.
Do not use PVC pipe for drain.
D
Right - 3”, Left - 3”,
.
Rear - 3” (12” on control
side if adjoining wall or
equipment is over 30” high
for service access)
Contact factory for
ariances to c
v
(NOT
.
SECT
Litho in U.S.A.
learances.
O SCALE)