Cleveland
™
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
FCSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
PRESSURE STEAMERS
PRESSURE STEAMERS
2 OR 3 OR 4 COMPARTMENTS
DIRECT STEAM, OPEN STAND
PEDESTAL BASE OR WALL MOUNTED
Cleveland Standard Features
n 5 psi Operating Pressure in cooking compartments
n
Mechanical interlock prevents unlatching door while compartment
is pressurized
imers, one per compartment, are mechanical style with
n T
audible signal
n
Thermostatic Trap vents cooking compartment automatically
n Steam Inlet Valves and Exhaust Valves interlocked for
synchronous action
n 8 psi Compartment Safety Valve
n Capacity per compartment for eight, 12” x 20” x 2 1/2” deep
Cafeteria Pans, or four, 18” x 26” Bun Pans
n Heavy Duty, free floating, cast aluminum compartment
doors
n Compartment Door Hinges have adjustable hinge pins and
self-lubricating bushings
n Door Gasket replaceable without tools
n Pressure Gauge for compartment Operating Pressure
n Compartment Slide Racks are removable without tools, for
easy cleaning
n Type 430 Stainless Steel: external enclosure, Table Top and
eight gauge plate cooking compartments
n Moisture Separator for incoming steam
n Pressure Reducing Valve for 12 to 50 psi steam supply
pressure
n 6” Adjustable Legs with flanged feet
MODELS:
2 Compartments 3 Compartments 4 Compartments
c PDL-2 c PDL-3 c PDL-4
c PDW-2 c PDW-3 c PDW-4
Short Form Specifications
Shall be _____ Compartments, CLEVELAND, Pressure Steamer,
Model PD- _____ - _____ , for Direct Steam operation,; _____ volts, single phase. Each Cooking Compartment equipped with: 60 Minute
Timer; Pressure Safety Valve; Heavy-duty, free floating Door with
Safety Interlock; and synchronous operating Steam Inlet and
Exhaust/Drain Valves. Compartments are mounted to a Low Cabinet
type base or Wall Mounted. Includes a Pressure Reducing Valve
and Moisture Separator.
Options & Accessories
p Automatic Steam Inlet and Exhaust Operation (AT-2):
includes 60 minute
p Second Pressure Reducing Valve for 50 to 120 psi supply
pressure (PR
p Special Compartment Slide Racks
p 12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep
p Intermediate Pull-Out Shelf (POS)
all Carrier, for wall mounted units only (IWC-PDW)
p In-W
Automatic
V)
imers and Manual Bypass
T
s Clean, non toxic, uncontaminated steam is required for all
“Direct Steam” steamers
SECT. VI PAGE 9
0707
Each compartment has capacity for:
•
E
ight, 12˝ x 20˝ x 2
1
⁄2˝
Cafeteria Pans or
Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or
Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or
Four, 18˝ x 26˝ Bun Pans
Many regional, state and local codes exist and it is
•
t
he responsibility of the owner and installer to com-
ply with those codes.
Cleveland Range equipment is built to comply with
•
applicable standards for manufacturers. Included
a
mong those approval agencies are: UL, ULC, NSF,
and CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
w
hether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be
necessary. The fact that a water supply is potable is not
proof that it will be suitable for the generator.
WALL MOUNTED
1” IPS common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
drain.
Cleveland Range reserves right of design improvement or modification, as warranted.
LOW-CABINET TYPE
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment
is over 30” high for service
access)
Contact factory for
variances to clearances.
SECT
O SCALE)
T
(NOT
.
AGE
VI P
Litho in U.S.A.
10
0707