Cleveland Range CSTK-610, CSTK-610CA User Manual

Page 1
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
by
Cleveland
U
NIT A
UNIT B
6.00"
NOTE: Overall height of unit does not change for units with casters.
RC
CS
W1 W2
D
G
4
.38"
NOTE: Overall height of unit does not change for units with casters.
RC
CS
W1W
2
D
G
RC
CS
W1 W2
D
G
4.38"
38.08"
3
9.21"
L
EFT SIDE VIEW
6.10 on 6.10 GAS
U
NIT A
UNIT B
3
6.70"
1.58"
28.43
5
.00"
1
.82"
67.8 5 "
28.43
6.00"
78.00” (MIN.HOOD REQUIREMENT)
2
.52"
W1
W2
D
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
W1
W2
D
RC
W1
W2
D
RC
CS
W1
W1
W2
COMBI OVEN-STEAMER Stacking Kits for Gas Table Type Models (OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)
Model # Description
CSTK-610 for mounting two 6.10 models
STK-610CA for mounting two 6.10 models (with casters)
C
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factor
y ser
vice department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
Gas Connection: 3/4" NPT
ype:
Gas T Gas Flow Pressure:
BOILER MODELS UNIT A - OGB-6.10 UNIT B - OGB-6.10
otal Connected Load:
T Steam Generator: Hot Air: 45.400 BTU 45.400 BTU
BOILERLESS MODELS UNIT A - OGS-6.10 UNIT B - OGS-6.10
otal Connected Load:
T Hot Air:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
120 volt, 60 Hz, single phase,
UNIT A ­UNIT B -
11.7 amps
11.7 amps
Natural Gas (Propane optional) Natural Gas - Min. 5.5" WC / Max. 14" WC Propane Gas - Min. 11" WC / Max. 14" WC
45.400 BTU
45.400 BTU
45.400 BTU
45.400 BTU
45.400 BTU
45.400 BTU
45.400 BTU 45.400 BTU
Water Connections: Cold Water (drinking water quality) Flow Pressure:
ater Inlets: 3/4" GHT-F (Female Garden Hose Connection)
W
30 - 60 PSI
reated W
T
ater for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
enting:
V
*Connection for Cleaning Solution
*Connection for Rinse Cycle
Exhaust Hood required
*
Available as an option
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5A
0707
Page 2
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
by
Cleveland
UNIT A
UNIT B
6.00"
R
C
C
S
W1W
2
D
G
4.38"
NOTE: Overall height of unit does not change for units with casters.
U
6.10 on 10.10 GAS
RC
CS
W1 W2
D
G
RC
CS
W1 W2
D
G
4.38"
48.54”
39.21"
NOTE: Overall height of unit does not change for units with casters.
UNIT A
UNIT B
L
EFT SIDE VIEW
78.41"
36.70"
1.58"
1
.82"
28.43
5.00"
38.98"
6.00"
80.00” (MIN.HOOD REQUIREMENT)
2.52"
W1
W2
D
W1
W2
D
RC
S
CS
AV
G
W1
W1
W2
W1
W2
D
W1
W2
D
RC
W1
W2
D
RC
CS
COMBI OVEN-STEAMER Stacking Kits for Gas Table Type Models (OGB 6.10 on OGB 10.10 or OGS 6.10 on OGS 10.10)
Model # Description
CSTK-1010 for mounting one 6.10 model on top of one 10.10 model
CSTK-1010CA for mounting one 6.10 model on top of one 10.10 model (with casters)
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
Rear - 2", Left Side - 4", Right Side - 2 1/2"
Water Connections: Cold Water (drinking water quality) Flow Pressure:
ater Inlets: 3/4" GHT-F (Female Garden Hose Connection)
W
• Allow for sufficient clearance on left side for service access (contact the factor
y ser
vice department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
Gas Connection: 3/4" NPT
ype:
Gas T Gas Flow Pressure:
BOILER MODELS UNIT A - OGB-6.10 UNIT B - OGB-10.10
otal Connected Load:
T Steam Generator: Hot Air: 45.400 BTU 75,700 BTU
BOILERLESS MODELS UNIT A - OGS-6.10 UNIT B - OGS-10.10
otal Connected Load:
T Hot Air:
120 volt, 60 Hz, single phase,
Natural Gas (Propane optional) Natural Gas - Min. 5.5" WC / Max. 14" WC Propane Gas - Min. 11" WC / Max. 14" WC
45.400 BTU
45.400 BTU
45.400 BTU
UNIT A ­UNIT B -
75,700 BTU 68,200 BTU
75,700 BTU
11.7 amps
11.7 amps
Drain Connection: 2" Tube
enting:
V
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
45.400 BTU 75,700 BTU
30 - 60 PSI
ater for Steam Generator
reated W
T
Untreated Water for Condenser
Exhaust Hood required
SECT. IIB PAGE 5B
0707
Page 3
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
by
Cleveland
2.52"
30.12"
5.00"
30.12"
6.00"
47.92"
1.58"
1
.82"
71.24"
NOTE: Overall height of unit does not change for units with casters.
78.00” (MIN.HOOD REQUIREMENT)
RC
CS
W1W
2
D
G
RC
CS
W1 W2
D
G
4.38"
39.50"
47.72"
U
NIT A UNIT A
UNIT B
UNIT B
L
EFT SIDE VIEW
F
RONT VIEW
6.20 on 6.20 GAS
W1
W2
D
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
W1
W2
D
RC
W1
W2
D
RC
CS
W1
W1
W2
COMBI OVEN-STEAMER Stacking Kits for Gas Table Type Models (OGB 6.20 on OGB 6.20 or OGS 6.20 on OGS 6.20)
Model # Description
CSTK-620 for mounting two 6.20 models
STK-620CA for mounting two 6.20 models (with casters)
C
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factor
y ser
vice department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
Gas Connection: 3/4" NPT
ype:
Gas T Gas Flow Pressure:
BOILER MODELS UNIT A - OGB-6.20 UNIT B - OGB-6.20
otal Connected Load:
T Steam Generator: Hot Air: 75,700 BTU 75,700 BTU
BOILERLESS MODELS UNIT A - OGS-6.20 UNIT B - OGS-6.20
otal Connected Load:
T Hot Air:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
120 volt, 60 Hz, single phase,
Natural Gas (Propane optional) Natural Gas - Min. 5.5" WC / Max. 14" WC Propane Gas - Min. 11" WC / Max. 14" WC
75,700 BTU 68,200 BTU
75,700 BTU 75,700 BTU 75,700 BTU
UNIT A -
11.7 amps
UNIT B -
11.7 amps
75,700 BTU 68,200 BTU
75,700 BTU
Water Connections: Cold Water (drinking water quality) Flow Pressure:
ater Inlets: 3/4" GHT-F (Female Garden Hose Connection)
W
30 - 60 PSI
reated W
T
ater for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
enting:
V
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5C
0707
Page 4
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
by
Cleveland
6.20 on 10.20 GAS
80.09"
47.92"
2
.52"
1.58"
1.82"
30.12"
5.00"
38.98"
6.00"
81.00” (MIN.HOOD REQUIREMENT)
RC
CS
W1 W2
D
G
RC
CS
W1 W2
D
G
4.38"
48.32"
47.72"
NOTE: Overall height of unit does not change for units with casters.
U
NIT A UNIT A
UNIT B
UNIT B
L
EFT SIDE VIEW
FRONT VIEW
W1
W2
D
W1
W2
D
RC
S
CS
AV
G
W1
W1
W2
W1
W2
D
W1
W2
D
RC
W1
W2
D
RC
CS
COMBI OVEN-STEAMER Stacking Kits for Gas Table Type Models (OGB 6.20 on OGB 10.20 or OGS 6.20 on OGS 10.20)
Model # Description
CSTK-1020 for mounting one 6.20 model on top of one 10.20 model
CSTK-1020CA for mounting one 6.20 model on top of one 10.20 model (with casters)
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
Rear - 2", Left Side - 4", Right Side - 2 1/2"
Water Connections: Cold Water (drinking water quality) Flow Pressure:
ater Inlets: 3/4" GHT-F (Female Garden Hose Connection)
W
• Allow for sufficient clearance on left side for service access (contact the factor
y ser
vice department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
120 volt, 60 Hz, single phase,
UNIT A ­UNIT B -
11.7 amps
15.9 amps
Drain Connection: 2" Tube
Gas Connection: 3/4" NPT
ype:
Gas T Gas Flow Pressure:
BOILER MODELS UNIT A - OGB-6.20 UNIT B - OGB-10.20
otal Connected Load:
T Steam Generator: Hot Air: 75,700 BTU 132,700 BTU
BOILERLESS MODELS UNIT A - OGS-6.20 UNIT B - OGS-10.20
otal Connected Load:
T Steam Generator:
Natural Gas (Propane optional)
enting:
V
Natural Gas - Min. 5.5" WC / Max. 14" WC Propane Gas - Min. 11" WC / Max. 14" WC
75,700 BTU 68,200 BTU
75,700 BTU 75,700 BTU 132,700 BTU
132,700 BTU 113,600 BTU
132,700 BTU
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
30 - 60 PSI
ater for Steam Generator
reated W
T
Untreated Water for Condenser
Exhaust Hood required
SECT. IIB PAGE 5D
0707
Page 5
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
by
Cleveland
6
.00"
78
RC
CS
W1 W2
D
4.38"
39.50"
4
NOTE: Overall height of unit does not change for units with casters.
U
37.83"
LEFT SIDE VIEW
36.70"
1.58"
1
.82"
2.52"
RC
CS
W1 W2
D
RC
CS
W1 W2
D
NOTE: Overall height of unit does not change for units with casters.
4.38"
3
8.08"
28.43
5.00"
67.8 5 "
28.43
6.00"
78.00” (MIN.HOOD REQUIREMENT)
U
NIT A
UNIT B
U
NIT A
UNIT B
6.10 on 6.10 ELEC
W1
W2
D
W1
W2
D
W1
W2
D
RC
W1
W2
D
RC
CS
W1
W1
W2
COMBI OVEN-STEAMER Stacking Kits for Electric Table Type Models (OEB 6.10 on OEB 6.10 or OES 6.10 on OES 6.10)
Model # Description
CSTK-610 for mounting two 6.10 models
STK-610CA for mounting two 6.10 models (with casters)
C
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
BOILER UNIT A - OEB-6.10 UNIT B - OEB-6.10 MODELS
Total Connected Load: Hot Air: 8.6 KW 11.4 KW 9.1 KW 10.2 KW 8.6 KW 11.4 KW 9.1 KW 10.2 KW Steam Generator: 7.7 KW 10.2 KW 8.6 KW 10.2 KW 7.7 KW 10.2 KW 8.6 KW 10.2 KW Amps per Phase: 27.3 30.8 15.2 16.3 27.3 30.8 15.2 16.3
BOILERLESS MODELS
Total Connected Load: Hot Air: 8.6 KW 11.4 KW 9.1 KW 10.2 KW 8.6 KW 11.4 KW 9.1 KW 10.2 KW Amps per Phase: 27.3 30.8 15.2 16.3 27.3 30.8 15.2 16.3
Rear - 2", Left Side - 4", Right Side - 2 1/2"
.I. outlet.
Do not connect to a G.F
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
9.9 KW 12.8 KW 11 KW 13.1 KW 9.9 KW 12.8 KW 11 KW 13.1 KW
UNIT A
- OES-6.10 UNIT B - OES-6.10
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
9.9 KW 12.8 KW 11 KW 13.1 KW 9.9 KW 12.8 KW 11 KW 13.1 KW
Water Connections: Cold Water (drinking water quality) Flow Pressure: 30 - 60 PSI
ater Inlets:
W
-F (Female Garden Hose
3/4" GHT Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
enting:
V
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5E
0707
Page 6
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
by
Cleveland
UNIT A
UNIT B
6.00"
R
C
C
S
W1W
2
D
4
.38"
NOTE: Overall height of unit does not change for units with casters.
RC
CS
W1 W2
D
RC
CS
W1W
2
D
3
7.83"
NOTE: Overall height of unit does not change for units with casters.
LEFT SIDE VIEW
U
NIT A
UNIT B
4.38"
48.54"
6.10 on 10.10 ELEC
78.41"
36.70"
1.58"
1.82"
28.43
5.00"
38.98"
6.00"
80.00” (MIN.HOOD REQUIREMENT)
2.52"
W1
W2
D
W1
W2
D
W1
W2
D
RC
W1
W2
D
RC
CS
W1
W1
W2
COMBI OVEN-STEAMER Stacking Kits for Electric Table Type Models (OEB 6.10 on OEB 10.10 or OES 6.10 on OES 10.10)
Model # Description
CSTK-1010 for mounting one 6.10 model on top of one 10.10 model
CSTK-1010CA for mounting one 6.10 model on top of one 10.10 model (with casters)
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factory
vice department for recommendations).
ser Installation must comply with all local fire and health codes.
Electrical Requirements:
BOILER UNIT A - OEB-6.10 UNIT B - OEB-10.10 MODELS
otal Connected Load:
T Hot Air: 8.6 KW Steam Generator: 7.7 KW Amps per Phase: 27.3 30.8 15.2 16.3 45.5 51.8 24.2 26.4
BOILERLESS MODELS
otal Connected Load:
T Hot Air: 8.6 KW Amps per Phase: 27.3
Do not connect to a G.F.I. outlet.
480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
440/3/60
240/3/60
208/3/60
12.8 KW 11 KW 13.1 KW 16.4 KW 21.6 KW 18.5 KW 22 KW
9.9 KW
11.4 KW 9.1 KW 10.2 KW 14.7 KW 19.6 KW 16.5 KW 19.6 KW
10.2 KW 8.6 KW 10.2 KW 12.8 KW 17.1 KW 14.3 KW 17.1 KW
UNIT A
- OES-6.10 UNIT B - OES-10.10
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
12.8 KW
9.9 KW
11.4 KW
30.8
11 KW
9.1 KW
15.2
13.1 KW
10.2 KW
16.3
21.6 KW 18.5 KW 22 KW
6.4 KW
19.6 KW 16.5 KW 19.6 KW
14.7 KW
51.8 24.2 26.4
45.5
Water Connections: Cold Water (drinking water quality) Flow Pressure: 30 - 60 PSI
ater Inlets:
W
-F (Female Garden Hose
3/4" GHT Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
enting:
V
*Connection for Cleaning Solution
Exhaust Hood required
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5F
0707
Page 7
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
by
Cleveland
71.20"
47.92"
2
.52"
1.58"
1.82"
30.12"
5.00"
30.12"
6.00"
78.00” (MIN.HOOD REQUIREMENT)
RC
CS
W1 W2
D
RC
CS
W1W
2
D
4.38"
39.50"
4
6.34"
NOTE: Overall height of unit does not change for units with casters.
U
NIT A UNIT A
UNIT B
UNIT B
L
EFT SIDE VIEW
F
RONT VIEW
6.20 on 6.20 ELEC
W1
W2
D
W1
W2
D
W1
W2
D
RC
W1
W2
D
RC
CS
W1
W1
W2
COMBI OVEN-STEAMER Stacking Kits for Electric Table Type Models (OEB 6.20 on OEB 6.20 or OES 6.20 on OES 6.20)
Model # Description
CSTK-620 for mounting two 6.20 models
STK-620CA for mounting two 6.20 models (with casters)
C
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to
• Allow for sufficient clearance on left side for service access (contact the factory
• Installation must comply with all local fire and health codes.
Electrical Requirements:
BOILER UNIT A - OEB-6.20 UNIT B - OEB-6.20 MODELS
Total Connected Load: Hot Air: 14.7 KW 19.6 KW 16.5 KW 19.6 KW 14.7 KW 19.6 KW 16.5 KW 19.6 KW Steam Generator: 12.8 KW 17.1 KW 14.3 KW 17.1 KW 12.8 KW 17.1 KW 14.3 KW 17.1 KW Amps per Phase: 45.5 51.8 24.2 26.4 45.5 51.8 24.2 26.4
BOILERLESS MODELS
Total Connected Load: Hot Air: 14.7 KW 19.6 KW 16.5 KW 19.6 KW 14.7 KW 19.6 KW 16.5 KW 19.6 KW Amps per Phase: 45.5 51.8 24.2 26.4 45.5 51.8 24.2 26.4
Rear - 2", Left Side - 4", Right Side - 2 1/2"
the unit.
service department for recommendations).
Do not connect to a G.F
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
16.4 KW 21.6 KW 18.5 KW 22 KW 16.4 KW 21.6 KW 18.5 KW 22 KW
UNIT A
- OES-6.20 UNIT B - OES-6.20
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
16.4 KW 21.6 KW 18.5 KW 22 KW 16.4 KW 21.6 KW 18.5 KW 22 KW
.I. outlet.
Water Connections: Cold Water (drinking water quality) Flow Pressure: Water Inlets: 3/4" GHT-F (Female Garden Hose
30 - 60 PSI
Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" T
ube
Venting: Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
Available as an option
*
Note: For additional connection details,
see spec sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5G
0707
Page 8
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
by
Cleveland
80.09"
47.92"
2.52"
1.58"
1.82"
30.12"
5.00"
38.98"
6.00"
81.00” (MIN. HOOD REQUIREMENT )
RC
CS
W1 W2
D
RC
CS
W1 W2
D
4.38"
4
8.32"
46.34"
NOTE: Overall height of unit does not change for units with casters.
UNIT A UNIT A
UNIT B
UNIT B
LEFT SIDE VIEW
F
RONT VIEW
6.20 on 10.20 ELEC
W1
W2
D
W1
W2
D
W1
W2
D
RC
W1
W2
D
RC
CS
W1
W1
W2
COMBI OVEN-STEAMER Stacking Kits for Electric Table Type Models (OEB 6.20 on OEB 10.20 or OES 6.20 on OES 10.20)
Model # Description
CSTK-1020 for mounting one 6.20 model on top of one 10.20 model
CSTK-1020CA for mounting one 6.20 model on top of one 10.20 model (with casters)
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
BOILER MODELS
otal Connected Load:
T Hot Air: 14.7 KW Steam Generator: 12.8 KW Amps per Phase: 45.5
BOILERLESS UNIT A - OES-6.20 UNIT B - OES-10.20 MODELS
Total Connected Load: Hot Air: 14.7 KW 19.6 KW 16.5 KW 19.6 KW 25.8 KW 34.3 KW 28.8 KW 34.3 KW Amps per Phase: 45.5 51.8 24.2 26.4 77.8 88.8 41.4 44.9
Do not connect to a G.F.I. outlet.
UNIT A
- OEB-6.20 UNIT B - OEB-10.20
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
21.6 KW
16.4 KW
19.6 KW
17.1 KW
51.8
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
16.4 KW 21.6 KW 18.5 KW 22 KW 26.3 KW 34.9 KW 29.4 KW 34.9 KW
22 KW
18.5 KW
19.6 KW
16.5 KW
17.1 KW
14.3 KW
26.4
24.2
26.3 KW 34.9 KW 29.4 KW 34.9 KW
25.8 KW 34.3 KW 28.8 KW 34.3 KW
20.5 KW 27.3 KW 22.9 KW 27.3 KW
77.8 88.8 41.4 44.9
Water Connections: Cold Water (drinking water quality) Flow Pressure: Water Inlets: 3/4" GHT-F (Female Garden Hose
30 - 60 PSI
Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" T
Venting: Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
Available as an option
*
Note: For additional connection details,
see spec sheet for each individual combi model to be stacked.
ube
SECT. IIB PAGE 5H
0707
Loading...