THE STEAM GENERATOR IN THIS UNIT REQUIRES PERIODIC MAINTENANCE.
FAILURE TO PERFORM THE REQUIRED MAINTENANCE (BASED ON WATER
QUALITY AT THE INSTALLATION AND VERIFIED BY MAINTENANCE RECORDS)
WILL RESULT IN THE CANCELLATION OF WARRANTY COVERAGE ON THE
STEAM GENERATOR.
WATER QUALITY REQUIREMENTS
THE RECOMMENDED MINIMUM WATER QUALITY STANDARDS WHETHER
UNTREATED OR PRE-TREATED, BASED UPON 10 HOURS OF USE PER DAY, AND
A DAILY BLOWDOWN, ARE AS FOLLOWS:
TOTAL DISSOLVED SOLID
less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SlLICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CONSULT A LOCAL WATER TREATMENT SPECIALIST FOR AN ON SITE WATER
ANALYSIS AND THIER RECOMMENDATIONS CONCERNING STEAM GENERATOR
FEED WATER TREATMENT (IF REQUIRED), IN ORDER TO REMOVE OR REDUCE
HARMFUL CONCENTRATIONS OF MINERALS. THE USE OF HIGHLY MINERALIZED
WATER WILL MEAN THAT MORE FREQUENT SERVICING OF THE STEAM
GENERATOR WILL BE NECESSARY. THE FACT THAT A WATER SUPPLY IS
POTABLE IS NOT PROOF THAT IT WILL BE SUITABLE FOR THE GENERATOR.
TABLE OF CONTENTS
INSPECTION AND UNPACKING
INSTALLATION INSTRUCTIONS
Installation Policies 3
Basic Assembly 3 - 5
Installation Clearances 5
Service Connections 6
Electrical 6 - 7
Water 7
Recommended Plumbing 7 - 11
Water Quality Requirements 7
Drain 12
Start-Up and Check-Out 13
INTRODUCTION TO SteamCraft® III
Operational Safety 13
OPERATIONAL FUNCTIONS
Control Panel Overview 14
Setting Digital Time Display 14
"TIMED" -Mode14
"MANUAL" Mode 15
Special Notes About Control Pane! 15
Thermostatic Timer Compensation 15
PAGE
3
3 -12
13
14 -15
UNIT FUNCTIONAL TEST
Before S/N C 1613-88A-24 (with Thermistors) 15 - 17
After S/N C 1613-88A-23 (without Thermistors) 18 - 20
START-UP AND PREHEAT
STEAMING OPERATION
STEAMER TIMER SETTING GUIDE
PREVENTATIVE MAINTENANCE
CHEMICAL DESCALING INSTRUCTIONS
21 - 22
22 - 23
20
20
21
ELECTRICAL CIRCUITRY OVERVIEW 24
PRIMARY CIRCUITS
Testing of Heating Element s25
120 VACCIRCUITS
Water FBI Solenoid Valve 26
Condenser Water Solenoid Valve 26
Contactors: Front - 3-Pole (before S/N C 1613-88A-24) 26
4-Pote (after S/N C 1613-88A-23) 26
Rear- 3-Pole (before S/N C 1613-88A-24) 26
LOW VOLTAGE CIRCUITS AND CONTROL BOARD
Door Sensor 27
Membrane Switch 30
Compartment Temperature Switch 30
26
27-29
WATER LAVEL PROBES
General Description 30
Flood Probe 31
Water Level 32
Low Water Level 33
TEMPERATURE CONTROL CIRCUITS
General Description 34
Standby 34
Drain Temperature Adjust 4
Thermistors (on units before S/N C 1613-88A-24) 35
EXPLODED-VIEW ASSEMBLY DRAWINGS and PART IDENTIFICATION
Steam Generator. On units before S/N C 2937-88F-14 36
On units after S/N C 2937-88F-13 37
On units after S/N C 5080-88J-00 38-41
Heating Element s42-43
Probes 44-47
Water Inlet to Steam Generator
On units before S/N C 2937-88F-14 48
On units after S/N C 2937-88F-13 51
On units after S/N C 5519-88L-16 54
25
Water Inlet to Condenser System:
On units before S/N C 2937-88F-14 49
On units after S/N C 2937-88F-13 52
On units after S/N C 5519-88L-16 55
Drainage System: On units before S/N C 2937-88F-14 50
On units after S/N C 2937-88F-13 53
On units after S/N C 5519-88L-16 56
Electrical Components 57
Front Control Panel 58
Compartment Door and Hinge 59
On units after S/N C 6100-89B-27 60
Door Handle Assembly 62
Door Handle Assembly 63
Cold Water Inlet Strainer Assembly 64
MISCELLANEOUS PARTS LIST 65
WIRING DIAGRAMS
66 - 70
MAINTENANCE and REPAIR CENTERS
Page 3
INSPECTION
Before unpacking, visually inspect the shipping carton for evidence of any damage during shipment If there are
signs of possible damage, do not unpack the equipment. Notify the carrier that delivered the shipment so the canon
and its contents can be examined for any damage claims. Fill out all appropriate forms and have the examining
carrier sign and date each form. Do not install damaged equipment
UNPACKING
1. If the shipping carton has no signs of possible damage, unpack the equipment To remove the unit from the
carton, it is easiest to slit the canon in 4 comers and "peel" it away from the steamer. After removing the canon,
examine the steamer for signs of possible damage. If damage exists, detail your observations on a claims form
and give to the shipper (keep a copy for your records).
2. If the equipment is undamaged, lift the unit to the counter top OF stand where it is to be installed. Do not install
damaged equipment
INSTALLATION INSTRUCTIONS
WARNINGInstallation of this unit mas t be done by qualified plumbing and electrical! installation
personnel working to all applicable local and national codes. The equipment is to be
installed to comply with the Basic Plumbing Code of the Building Officials and Code
Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of
the Food and Drug Administration (FDA). Improper installation of this product could
cause injury or damage and void customer warranty.
INSTALLATION POLICIES:
• Cleveland Range equipment is designed and manufactured to comply with applicable standards
tuners. Included among those certification agencies which have approved the safety of the equipment design
and construction are: UL, NSF, CSA, and others.
• Cleveland Range equipment is designed and certified for safe operation only when permanently installed in
accordance with local and/or national codes. Many local codes exist, and it is the responsibility of the owner
and installer to comply with these codes.
• In no event shall Cleveland Range assume any liability damage or injury resulting from installation which are
not in strict compliance with our Installation Instructions. Specifically. Cleveland Range will not
assume any liability for damage or injury resulting from improper installat ion of equipment, including, but not
limited to temporary or mobile installations.
BASIC ASSEMBLY:
1. The four legs have adjustable feet and should be used to level the unit in both directions: front to rear and side
to side. It is important for good operation that the unit is level.
2. Open steamer door and remove package of operational pans. It will contain:
3. Pre-Assembled Parts. When the operating pans
package is removed, several pre-assembled parts
can be seen inside the unit. Do not attempt to
remove these parts.
(d) water level probes
(e) heating elements
(f) compartment drain screen
4. Install Drain Stopper (Before S/N C3991-88I-01).
With steamer door open, notice the opening in the
bottom of the compartment. This leads into the
Steam Generator. Inside the Steam Generator
about midway along the left -hand side, you will
find a square shaped fixture with a drilled hole on
top and another on the right side. This is the
Steam Generator drain. Place the Drain Stopper
vertically as shown. Make sure it seats firmly.
5. Install the Steam Generator Cover. This cover is
designed to be installed in only one way. Refer to
illustration (b) in Step 2 above. Using both hands,
lift and locat e the cover above the Steam
Generator opening. Lower the cover until it fits
firmly into place.
6. Install the Pan Slide Racks. Each slide rack has 4
'loops' which are designed to loop-over' the
stainless steel hanger pins pre-mounted on each
compartment wall Position the 2 upper loops on
the 2 upper hanger pins. Let go. Now place your
hand on bottom of slide rack and gently move the
slide rack upward, allowing top of slide rack to
lean against compartment wall Bottom loops will
easily 'loop-over' bottom hanger pins, Slide rack is
now in position. Pans will slide easily on property
installed slide racks.
7. Check to insure that the Compartment Drain
Screen is free of debris. It is in the left rear comer
of the compartment floor.
Page 5
The 40 - MESH STRAINER and 1/4" Brass NIPPLE (P/N
102383) are preassembled and ready for quick installation
into the 1/4"" Bulkhead Coupling (see COLD WATER INLET)
located on the lower, right rear of the steamer.
Apply Pipe Dope or Teflon Tape to the 1/4"Brass Nipple.
Turn the 1/4" Brass Nipple (and Strainer) into the 1/4"
Bulkhead Coupling. Using a Pipe Wrench, turn the Strainer,
so that the 1/4" Brass Nipple is snug in the 1/4" Bulkhead
Coupling (Cold Water Inlet) and the Strainer is in a vertical
position as shown (with nut in downward position).
Then flush the Cold Water Inlet line (to be provided by the
installer) before connecting it to the Strainer. Be sure to check
.for any leakage and adjust accordingly.
9. Drain Valve Location and Operation.
The Drain Valve is located in the rear left comer, underneath the steamer. When the red handle is turned toward
the front of the unit the drain valve is open. (see illustration below) A 90° turn to the right will dose the valve.
INSTALLATION CLEARANCES:
The steamer should be installed with the following clearances:
• Left = 2"
• Right = 2"
• Top = 2"
• Bottom =4" (4" legs already mounted to unit)
Page 6 CET-8 Service Manual
SERVICE CONNECTIONS:
(A) Hole for electrical conduit connection leads to terminal block and
ground connection inside unit. On C.S.A. (Canadian Standards
Association) units 6 feet of flexible electrical conduit is already
attached to the unit for the electrical supply connection.
(B) 1/4" 0 COLD WATER INLET for Steam Generator feed water.
(On units before S/N C 5519-88L-17)
(B) Location for SteamerGard Water Treatment System.
Installation Optional. (On units after S/N C 5519-88L-16)
(C) 1/4" 0 COLD WATER INLET for Condenser feed water.
(On units before S/N C 5519-88L-17)
(C) 1/4" diameter COLD WATER INLET for Steam Generator (Boiler)
feed water and Cold Water Condenser. (On units after S/N C 551988L-16)
(D) Drain (On units after S/N C 2937-88F-13)
ELECTRICAL:
1. Install in accordance with local codes and/or the National Electric Code, ANSINFPA No. 70-1987 (USA) or the
Canadian Electrical Code CSA Standard C22.1 (Canada). A separate fused disconnect switch must be installed
for each unit. The steamer must be electrically grounded by the installer.
2. The electric supply must match the power requirements specified on the steamer's rating label. The copper wiring
must be sized to carry the required current at the rated voltage. See table below.
VOLTS
KW 3PH AMPS SIZE (AWG) 1PH AMPS SIZE (AWG)
208
220
240
380
415
460
480
8.1
7.4
8.8
7.4
8.8
7.4
8.8
23
20
22
12
13
10
11
10
10
10
12
12
14
14
39 8
34 8
37 8
20 10
22 10
18 12
18 12
NOTE: Use copper wire suitable for not les s than 75° C
3. Locate the six (6) screws that hold the rear panel to steamer and
remove them. (Save to use again.) Remove rear panel, expos ing
the terminal block on bottom panel of unit. Connect with properly
sized copper wire. On C.S.A. units 6 feet of flexible conduit is
already attached to the terminal block for the electrical supply
connection
CET-8 Service Manual Page 7
4. The steamer is wired 3-phase delta operation at the factory. For single phase operation, the installer must change the two
jumpers on the terminal block to that shown in the accompanying diagram (and on the steamer's wiring diagram label).
5. The steamer will be wired 3 phase WYE connection at the factory. For steamers ordered for 380/220 V or 415/240 V, 4 wire 3
phase.
WATER
A 1/4" l.P.S. (M1N. SIZE) COLD water line is required. DO NOT USE HOT WATER. Minimum water pressure
(dynamic) is 35 psi (2.4 kg/cm), the maximum static water pressure is 60 psi (4.1 kg/cm).
Water Quality Requirements
If the purity of the incoming water is good, the generator, the heating element and the valves should give years
of trouble-free, efficient service with a minimum of servicing.
The recommended minimum water quality standards, whether untreated or pretreated. for the Steam Generator
are as follows:
• TOTAL DISSOLVED SOLIDS less than GO parts per million • SILICA less than 13 parts per million
• TOTAL ALKALINITY less than 20 pans per million • pH FACTOR greater than 7.5
Consult a local water treatment specialist for an on-the-premises water analysis and for recommendations
concerning steam generator feed water treatment (if required), in order to remove or reduce harmful
concentrations of minerals. The use of a poor quality (highly mineralized) water will mean that more frequent
servicing of water sensitive components will be necessary. The fact that a water supply is potable is not proof
enough that it will not be detrimental to the water sensitive components.
Recommended Plumbing
• On units (before S/N C 5519-88L-17) the steamer has two Cold Water Inlet Fittings at the lower right -hand
side of the rear panel. The fitting on the left feeds the Cold Water Inlet to the Steam Generator (See figures
13 and 16) and the one on the right feeds the Cold Water Condenser System. (See figures 14 and 17)
Decals mark the respective fittings. When using treated water, only the Cold Water Inlet to the Steam
Generator need be connected to the treater; the Cold Water Condenser System can use untreated water.
• On units (after S/N C 5519-88L-16) the steamer has one Cold Water Inlet Fitting at the lower right -hand side
of the rear panel (See illustration on page 5). When using a Water Treatment System, the connection for the
Steam Generator (Boiler) is made through the optional hole provided. This process will also require additional parts. The Cold Water Condenser System can use untreated water. (See illus tration on page 11). NOTE:
See rear view drawing in "Service Connections, "B & C (page 6).
page 8 CET-8 Service Manual
Recommended Plumbing (Continued)
NOTE: This water supply arrangement is used on
units before S/N CS519-88L-17.
TOP VIEW
Recommended Plumbing (Continued)
NOTE: This water supply arrangement is used on
units before S/N C5519-88L-17.
CET-8 Service Manual Page 9
TOP VIEW
RECOMMENDED PLUMBING
WATER
TREATMENT
SYSTEM:
Page 10 CET-8 Service Manual
Recommended Plumbing (Continued)
NOTE: This water supply arrangement is used
on units before S/N C5519-88L-16.
REAR VIEW
TOP VIEW
Recommended Plumbing (Continued)
CET-8 Service Manual Page 11
NOTES:
1. This water supply arrangement is used on units
after S/N C5519-88L-16.
2. The conversion kit for converting one incoming
water line into two for a treatment system is P/N
102431.
WATER TREATMENT SYSTEM
RECOMMEMDED PLUMBING
( to be supplied by installers)
WATER
TREATMENT
SYSTEM:
Page 12 CET-6 Service Manual
Drain
This drain line outlet discharges exhaust steam and hot condensate. Connect 1-1/4" I.P.S. piping (or larger) to
extend the drain line to a nearby open floor drain. Up to two elbows and six feet of 1-1/4" I.P.S. (or larger)
extension pipe should be connected to the drain termination. Drain piping extended six to twelve feet. or using
three elbows, should be increased to 2" I.P.S. - DO NOT, UNDER AN CIRCUMSTANCE, CONNECT ANY OTHER EQUIPMENT DRAIN TO THIS DRAIN LINE. The extension piping must have a gravity flow and vent
freely into the air. This drain outlet must be free vented to avoid the creation of back pressure in the steamer
cooking compartments.
To ensure a vented drain line, DO NOT, UNDER ANY CIRCUMSTANCE, CONNECT THE DRAIN
OUTLET DIRECTLY TO THE FLOOR DRAIN OR SEWER LINE.
Do not run the drain fine discharge into PVC drain piping or any other drain material not capable of sustaining
180°F operation. The equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials
and Code Administrators International, Inc: (BOCA) and the Food Service Sanitation Manual of the Food and Drug
Administration (FDA).
In making a connection to the dram termination use a hardening type of pipe sealant. FINGER TIGHTEN ONLY -
DO NOT USE A WRENCH.
FAILURE TO OBSERVE THESE REQUIREMENTS CAN RESULT IN DAMAGE TO EQUIPMENT AND/OR THE
POSSIBILTY OF INJURY.
If these instructions are not complied with, there will be steam and water leakage past the
compartment door. Furthermore, the possibility of serious personal injury may result.
CET-8 Service Manual Page 13
Start-Up and Check-Out
1. Be sure to put the Steam Generator Cover in its' proper location.
2. Close Drain Valve.
3. Turn on water at supply valve.
4. Turn on electricity at Fused Disconnect Switch.
5. Close steamer door.
6. Press "POWER" touch pad.
7. Set Timer display at "01"minutes.
8. Press "TIMED" touch pad. The unit will HI with water and begin to make steam. After the compartment reaches
operating temperature the timer will count down to "00" and an alarm will beep. This test will take 5 to 10
minutes.
9. Press "MANUAL* touch pad. The Heater Elements and the Cold Water Condenser will turn on. Open and dose
the door several times to ensure that the steam shuts off with the door open.
INTRODUCTION TO
To get the full advantage of steam cooking, the Cleveland SteamCraft III must be properly installed. A steamer
which is improperly installed, improperly used, improperly maintained, or improperly repaired will create a
dangerous condition and may cause injury to personnel.
OPERATIONAL SAFETY
Your Cleveland SteamCraft III will require minimum servicing provided it is operated according to instructions and
given the care recommended.
Make sure that responsible personnel understand how your steam cooking equipment should be operated and
cared for. Proper use and maintenance pay handsome dividends in longer equipment He and satisfactory
performance minimal down-time.
Safe steam cooking equipment operation dictates that every owner should follow these rules for operational safety.
1. Begin a comprehersive, continuous program of steam cooking equipment inspection.
2. Never allow untrained personnel to operate your steam cooking equipment. Establish an in-house training
policy and adhere to ft.
3. At the end of each day's operat ion:
-Shut unit down at the end of each day's operation according to instruction on pages 21 -22.
-Remove any spilled food, then wash the racks and compartment interiors thoroughly with mid detergent in
warm water. Rinse thoroughly with dean warm water. (Racks can be removed and washed in a dishwasher if
desired. To reinstall see Basic Assembly instructions, page 4.)
Let rinse water drain through compartment drain opening. If water does not drain freely,
drain lines must be cleaned out before cooking again. Clogged or slow drains are
dangerous because hot water may spill out when compartment doors are opened during
or after a cooking cycle.
-Before cleaning the steamer's exterior, BE SURE THAT ELECTRICITY TO THE UNIT AT FUSED
DISCONNECT SWITCH IS OFF. Use a damp cloth for cleaning. Never hose down the equipment.
4. Read and follow Cleveland Range instructions on steamer and steam generator maintenance.
5. Use only replacement parts which are factory authorized to preserve the certification of Underwriters
Laboratories, Canadian Standards Association, and all approvals and to protect your warranty coverage.
6. Never allow unqualified personnel to service your steamer.
Page 14 CET-8 Service Manual
OPERATIONAL FUNCTIONS
Operation of the Cleveland SteamCraft III is very easy. Each operator should become familiar with the
following operational functions and procedures to effectively start, operate, and shut down the steamer.
CONTROL PANEL OVERVIEW:—————————————————————————————————————
1. "POWER" -ON and OFF touch pad controls the power to unit. The red indicator light above the touch •pad is
illuminated when the power is ON.
2. "MANUAL" -ON and OFF touch pad controls the manual operation. The green indicator light above the touch
pad is illuminated when operating in the manual mode.
3. "TIME SET" -Directional touch pads are used to adjust the time on the DigitaI Time Display located above the
two touch pads. A maximum of 99 minutes can be programmed. The green indicator fight to the
right of the Digital Time Display flashes when the steaming compartment is at steaming
temperature and the time is counting (up or down).
4. "TIMED" -ON and OFF touch pad controls the timed operation. The green indicator light above the touch pad
is illuminated when operating in the TIMED mode.
5. "FLOOD" -FLOOD is a safety signal. POWER to the unit will automatically turn off when the signal
comes on. Refer to the troubleshooting section when displayed.
6. "WATER" -WATER illuminates as the steam generator fills turns off when the water level reaches the
safe operating level.
The touch pad controls are designed to be pressed with finger tips only. Be careful not to use
fingernails, kitchen utensils or anything that could cause damage.
SETTING DIGITAL TIME DISPLAY: —————————————————————————————————————————
————
To set Digital Time Display for TIMED mode, press and hold the "LEFT" touc h pad and the
display will begin counting upward from 01 to 10 slowly, then more quickly. Run the time up until
display is dose to (or over) value wanted, then use the "LEFT" and "RIGHT" touch pads to set
actual time desired. Digital time Display must be reset before each new cooking process can
begin. (Refer to the Steamer Timer Setting Guide on page 21 for suggested settings.)
TIMED MODE: ————————————————————————————————————
If TIMED operation is desired, cooking time must be set on Digital time Display. Begin timed
cooking by pressing "TIMED" touch pad. The green indicator light above the "TIMED" touch
pad will become illuminated. When the unit reaches cooking temperature, the timing sequence
will begin and win be confirmed by a flashing green indicator light to the right of the DIGITAL
TIME DISPLAY. At the conclusion of the timed period, the DIGITAL TIME DISPLAY will flash
00. the green indicator light will go out and a 4 second beeping signal win begin.
OPERATIONAL FUNCTIONS (Continued)
MANUAL MODE:
If TIMED operation is NOT desired, unit may be operated in the MANUAL mode by
pressing the "MANUAL" touch pad which turns the steam flow ON and OFF. The green
indicator light above the "MANUAL" touch pad will be illuminated when unit is ON in the
MANUAL mode. (When operating in the MANUAL mode, the Digital Time Display will start
at 00 and count upward, after the steaming compartment reaches cooking temperature,
keeping actual time lapsed.)
SPECIAL NOTES ABOUT CONTROL PANEL:
• Above the "POWER" touch pad is an alert signal which will begin flashing FLOOD - if
the water level controls or drain are not functioning properly and water threatens to
overflow the steam generator. This signal means the unit has shut off the water and all
other func tions.
• Above the "MANUAL" touch pad is a signal which will light up - WATER. It indicates insufficient water level in the steam generator and will automatically go off when a safe
water level is attained. Steamer will not produce steam when this light is on.
CET-8 Service Manual Page 15
NOTE: the event that either of these two-word displays do NOT turn off at the proper time and no
quick remedy can be found (turning of a water valve, etc.) the unit will require the attention
of an Authorized Service Representative.
If FLOOD light is flashing, DO NOT OPEN COMPARTMENT DOOR! Shut off wetter supply
to unit. Flood may be caused by damaged water feed valve. Allow unit to cool before
opening compartment door.
THERMOSTATIC TIMER COMPENSATION:
Whenever this automatic adjustment is taking place, the DIGITAL TIME DISPLAY
will stop counting down (or up if in "MANUAL" mode) and the green indicator light
will stop flashing. Both will remain illuminated. When the steaming compartment
reaches a preset temperature, the steaming operation will automatically begin.
This feature doesn't require any control settings by the owner. It is an automatic
function designed to ensure consistent cooking results whether your food product
is frozen (needing thawed) or if the compartment door is opened too often.
UNIT FUNCTIONAL TEST
Before S/N: C 1613-88A -24 (with Thermistors)
NOTE: This test is intended to be carried out after the unit is installed. If the water,
drain and electrical hook up has been completed property then proceed with
test.
1) Open customer's water supply valve.
2) Check for water leakage at all visible pipe joints, tube connections or unions. Wait a few minutes then look for
water leaking from body of unit. If any leakage is found, repair leaks before continuing.
3) Turn on electricity at Fused Disconnect Switch.
Page 16 CET-8 Service Manual
4) Check to see that front control panel is off and is not illuminated.
5) Short the flood probe (upper most) to generator or ground. "FLOOD" light should begin to flash within three to four
seconds. Push "POWER" touchpad. Unit should not turn on. "FLOOD" light will continue to flash.
6) Turn off electricity to the unit at Fused Disconnect Switch and wait ten seconds. Restore electricity to the unit at
the Fused Disconnect Switch.
7) Close Steam Generator drain by removing Steam Generator Cover and placing drain stopper into opening located
along left hand side.
8) Push "POWER" touchpad on front control panel.
9) Red indicator light above the "POWER" touchpad, digit displays and "WATER" indicator will light.
10) After approximately five seconds, the water fill solenoid will energize and water will begin to fill the Steam Generator.
11) Check for water leakage around the base of the unit.
12) When water level reaches the low water cutoff probe (lowest) the "WATER" indicator will turn off and heater contactor will be energized. One heating element will begin to heat the water in the Steam Generator.
13) With compartment door open, push "MANUAL" touchpad. Green indicator above touchpad
14) Contactor and heater will turn off.
15) Push "MANUAL" touchpad again.
16) Heater turns on and green indicator turns off.
17) As the Steam Generator temperature reaches "standby temperature" the contactor will be de-energized and
heater will turn off.
18) Check that Steam Generator did not come to boil and that water level is correct Water temperature should be
between 180° and 190° degrees F.
19) Push "MANUAL" touchpad. Green indicator above touchpad will light. Close compartment door.
20) When compartment door is dosed the condenser solenoid valve and heater contactors will be energized.
21) Check for water flow from drain. Look for water leakage around base of unit
22) Open compartment door. Condenser water and heaters will turn off.
23) Position a test magnet on top of the control panel enclosure over door sensor. Condenser and heaters will turn
on.
24) Watch heaters in Steam Generator to determine that all three are working.
NOTE: This test is best done with cold water in the Steam Generator so that any
differences in heater output may be more easily detected. It may be necessary
to drain and refill Steam Generator before continuing.
CET-8 Service Manual Page 17
25) Push "MANUAL" touchpad and remove test magnet.
26) Install Steam Generator Cover and close compartment door.
27) Push and hold "LEFT" Time Set touchpad.
28) Digit displays should count up at two per second for first 5 seconds (display of "00" through "10"). After five
seconds displays will count at 20 per second until switch is released.
29) Release and push the "LEFT" Time Set touchpad again.
30) Digits will return to slow counting.
31) Release "LEFT" Time Set touchpad. Repeal steps 27 thru 30 this time pushing "RIGHT" Time Set touchpad.
32) Set time display to "01" and push TIMED" touchpad.
33) As cooking cycle is started the condenser and all heaters will turn on. The green indicator to the right of the
time display will not be flashing.
34) When the compartment reaches operating temperature the green Indicator to the right of the digit displays
win begin to flash. At this time one heater contactor should be cycling on and off approximately once every 5
35) Turner will count down to "00" one minute after the flashing indicator is first lit, this will end the timed
cooking style cycle.
36) At the end of the cycle the heaters and condenser will turn off. the digit displays will flash ("00") and the
alarm will beep four times.
37) Push "TIMED" touchpad to stop flashing of the displays.
38) Set timer to any setting over "00".
39) Push "MANUAL" touchpad.
40) Digit display will reset to "00", heaters and condenser will turn on and green indicator by digit displays will
flash.
41) Allow the unit to run for at least one minute to see that timer counts up in manual operation.
42) Open compartment door carefully Avoid hot steam contact.
43) Steam and condenser should turn off. Within one minute after the door is opened the timer should stop
counting (green indicator stops flashing)
44) Push "POWER" touchpad one time. Unit turns off
45) End of test.
Page 18 CET-8 Service Manual
UNIT FUNCTIONAL TEST
After S/N: C 1613-88A -23 (without Thermistors)
NOTE: This test is intended to be carried out after the unit is installed. If the water,
drain and electrical hook up has been completed property, men proceed
with test.
1) Open customer's water supply valve.
2) Check for water leakage at all visible pipe joints, tube connections or unions. Wait a few minutes then look for
water leaking from body of unit. If any leakage is found, repair leaks before continuing.
3) Turn on electricity at Fused Disconnect Switch.
4) Check to see that front control panel power is off and it is not illuminated.
5) Short the flood probe (upper most) to generator or ground."FLOOD" light should begin to flash within four
seconds. Push "POWER" switch. Unit will not turn on. "FLOOD" light will continue to flash.
6) Turn off electricity to the unit at Fused Disconnect Switch and wait ten seconds. Restore electricity to the unit
Fused Disconnect Switch.
7) Close Steam Generator drain valve by reaching under the unit and pushing the handle to the right. (Units before
serial number C2937-88F-14 have a drain stopper in the generator that must be in place.)
8) Push "POWER" touchpad on front control panel.
9) Red indicator light above the "POWER" touchpad, digit displays and "WATER" indicator will light.
10) After approximately five seconds, the water fill solenoid will energize and water will begin to fill the Steam Generator.
11) Check for water leakage around the base of the unit.
12) If you have removed the front control panel to check for water leakage, make sure ft is up in place and the
compartment door is closed. When water level reaches the low water cutoff probe (lowest) the "WATER" indicator will
turn off and the heater contactor will be energized. The heating elements will begin to heat the water in the Steam
Generator.
13) Open the compartment door and the contactor and heaters will turn off.
14) Clos e compartment door. Push the "MANUAL" touchpad.
15) When compartment door is dosed the condenser solenoid valve and heater contactors will be energized.
16) Check for water flow from drain. Look for water leakage around base of unit.
17) Open compartment door. Condenser water and heaters will turn off.
18) Position a test magnet on top of the control panel enclosure over door sensor. Condenser and heaters will turn
on.
CET-8 Service Manual Page 19
19) Watch heaters in Steam Generator to determine that all three are working.
NOTE: This test is best done with cold water in the Steam Generator so that any
differences in heater output may be more easily detected. It may be
necessary to drain and refill Steam Generator before continuing.
20] Push "MANUAL" touchpad and remove test magnet.
21) Install Steam Generator Cover and dose compartment door.
22) Push and hold "LEFT" Time Set touchpad.
23) Digit displays should count up at two per second for first 5 seconds (display of "00" through "10"). After five
seconds displays will count at 20 per second until switch is released.
24) Release and push the "LEFT" Time Set touchpad again.
25) Digits should return to slow counting.
26) Release "LEFT" Time Set touchpad. Repeat steps 22 thru 25 this time pushing "RIGHT" Time Set touchpad.
27) Set time display to Wand push "TIMED" touchpad.
28) As cooking cycle is started the condenser and all heaters will turn on. The green indicator to the right of the time
display should not be flashing.
29) When the compartment reaches operating temperature the green Indicator to the right of the digit displays will
begin to flash. At this time one heater contactor should be cycling on and off approximately once every 5 seconds.
30) Timer will count down to "00" one minute after the flashing indicator is first lit, this win end the timed cooking
cycle.
31) At the end of the cycle the heaters and condenser will turn off, the digit displays will flash ("00") and the
alarm will beep four times.
32) Push TIMED" touchpad to stop flashing of the displays.
33) Set timer to any setting over "00".
34) Push "MANUAL" touchpad.
35) Digit display will reset to "00" heaters and condenser will turn on and green indicator by digit displays will flash.
36) Allow the unit to run for at least one minute to see that timer counts up in manual operation.
37) Open compartment door carefully. Avoid hot steam contact.
38) Steam and condenser should turn off. Within one minute after the door is opened the timer should stop count ing
(green indicator stops flashing).
39) Push "POWER" touchpad one time. Unit turns 08.