CLASSIC CONVECTION STEAMERS 15 PSI BOILER BASE STYLE
CONVECTION
®
ConvectionPro XVI
TWO LARGE COMPARTMENTS, PRESSURELESS 300M BTU GAS FIRED STEAM GENERATOR 36” WIDE CABINET BASE DESIGN, with NICKELGUARD™
Cleveland Standard Features
II
Cooking Capacity for up to eight 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans per compartment, or four 18˝ x 26˝ Buns Pans.
II
Pressureless cooking with forced convection steam, permitting doors to be opened while cooking continues.
II
Solid State Controls operate water level and safety functions. Each compartment is equipped with a 60 minute mechanica
II
timer, separate bypass switch for constant steaming.
II
Instant Steam Standby Mode: Holds generator at steaming temperature. Allows unit to start cooking instantly.
II
Durable 10 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
II
Separate Main Power Switch for “On/Off”
II
Exclusive Steam Cooking Distribution System:
sive Convection Jets produce a high velocity convection steam without fans. Coved Corner design in cooking compartment dis­tributes heat evenly and is easy to keep clean. Creased bottom enhances drainage. Cold Water Condenser for each compart­ment maintains a dry steam. Fully insulated cooking compart­ment for thermal efficiency. Removable Stainless Steel Slide Racks for easy cleaning.
II
Heavy duty, one piece, solid compartment door design with replaceable door gasket
II
Left Hand Door Hinging: Compartment Doors hinged left, controls on the right.
II
Modular Cabinet Base with Hinged Door.
Heavy duty Stainless Steel Base Frame.
II
II
High Efficiency Gas Steam Generator with NickelGuard,
Electronic Spark Ignition and Automatic Water Fill on start up.
II
Automatic Generator Drain at shutdown: Contains a “Water Jet” Spray Rinse Cleaning Cycle to keep drain clear.
II
Automatic Water Level Control System with Low Water Power Cut-off Circuit.
II
Steam generator equipped with High Limit Pressure Safety Switch, 15 psi Safety Valve, and Steam Generator Pressure Gauge.
II
NSF Certified 6˝ Stainless Steel Legs with adjustable flanged feet for a one inch level adjustment.
II
Gas Pressure Regulator and Control Valve.
II
Standard Voltage for Control: 115 volts, 60 Hz, single phase.
II
All Controls are serviceable from the front.
II
Compartment Door Steam Shut Off Switch.
Options & Accessories
Ë Electronic Timer with Compensating Load Feature. (ETC) Ë ON/OFF Steam Switch only for compartment controls (MC) Ë Cafeteria pans in depths of 1˝, 2
STEAMERS
1
2˝, 4˝ and 6˝
l
The exclu-
MODEL: 36-CGM-16-300
Shown with optional Electronic Timer
Short Form Specifications
Shall be Two Large Compartments, CLEVELAND Convection Steamer, Gas­fired Steam Generator, Model 36-CGM-16-300, NickelGuard, 300M BTU, _____ gas, _____ volts, _____ Hz, single phase. Solid State Controls operate timing, water level and safety functions.Type 304 Stainless Steel cooking compartment. Insulated cooking compartments. One 60 minute Mechanical Timer with Touch Control per compartment. Audible and Visual Signals for cycle completion and steam shut-off.
Ë 18˝ x 26˝ Bun Pans Ë Stainless Steel Insulated Flue Cover (SSF) Ë Quick Disconnect for gas line (QDC) Ë Correctional Packages Ë Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
Ë Boiler Descaling Pump Kit (107142) Ë Water Filters Ë Rear Gas Connection (RGT)
SECT. III PAGE 27
1007
E
ach compartment has capacity for:
E
ight, 12˝ x 20˝ x 2
a
ccomodate 18˝ x 26˝ Bun Pans.
1
2˝
deep Cafeteria Pans. Can
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of u
se per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million S
ILICA less than 13 parts per million
p
H FACTOR greater than 7.5
CHLORINE less than 30 parts per million
C
onsult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to r
emove or reduce harmful concentrations of minerals. The
u
se of highly mineralized water will mean that more
f
requent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
Right - 6”, Left - 6”, Rear - 6” (12” on control side if adjoining wall or equipment is over 30” high for service access)
** Do not connect to GFI outlet. See note below.
Do not use PVC pipe for drain.
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).
For use in non­combustible locations.
Contact factory for variances to clearances
(NOT TO SCALE)
SECT. III PAGE 28