Cleveland Range 24-CGM-200 User Manual

Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
1
0
0
%
5
Y
e
a
r
B
o
i
l
e
r
W
a
r
r
a
n
t
y
N
i
c
k
e
l
G
u
a
r
d
CLASSIC CONVECTION STEAMERS 15 PSI BOILER BASE STYLE
C
Cleveland Classic Series
TWO COMPARTMENT, PRESSURELESS 200M BTU GAS FIRED STEAM GENERATOR 24” WIDE CABINET BASE DESIGN, with NICKELGUARD™
Cleveland Standard Features
n
Cooking Capacity for up to six 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans.
n Pressureless cooking with forced convection steam, permitting
doors to be opened while cooking continues.
n
Solid State Controls operate water level and safety functions.
n
Each compartment is equipped with a 60 minute mechanical timer, separate bypass switch for constant steaming and a cold water condenser for superior cooking results.
n
Instant Steam Standby Mode: Holds generator at steaming temperature. Allows unit to start cooking instantly.
n Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
n Separate Main Power Switch for “On/Off” n Exclusive Steam Cooking Distribution System:
sive Convection Jets produce a high velocity convection without fans. Coved Corner design in cooking compartmen utes heat evenly and is easy to keep clean. Creased top & bottom enhance drainage. Cold Water Condenser for each compartment maintains a dry steam. Fully insulated cooking compartment for thermal efficiency. Removable Stainless Steel Slide Racks for easy cleaning.
n Exclusive “Cool to the Touch” Compartment Door Design:
Free floating inner door with reversible door gasket provides an air tight seal. Stainless Steel Slam/Latch Door Latch mechanism provides greater reliability.
n Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
n Modular Cabinet Base with Hinged Door. n High Efficiency Gas Steam Generator with NickelGuard,
Electronic Spark Ignition and Automatic Water Fill on start up.
utomatic Generator Drain at shutdown:
n A
Jet” Spray Rinse Cleaning Cycle to keep drain clear.
n Automatic Generator Mineral Purging Cycle automatically
cleans generator, reducing scale build up
n Automatic Water Level Control System with Low Water
Power Cut-off Circuit.
n
Steam generator equipped with High Limit Pressure Safety Switch, 15 psi Safety Valve, and Steam Generator Pressure Gauge.
n NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
n Gas Pressure Regulator and Control Valve. n Standard Voltage for Control: 115 volts, 60 Hz, single phase. n All Controls are serviceable from the front.
Options & Accessories
ONVECTION
STEAMERS
The exclu-
steam
t distrib-
Contains a “W
ater
MODEL: c 24-CGM-200
Short Form Specifications
Shall be Two Compartments, CLEVELAND Convection Steamer, Model 24­CGM-200, Gas-fired Steam Generator, NickelGuard, 200M BTU. Solid State Controls operate timing, water level and safety functions. Steam Generator with Automatic Water Fill on start-up, Automatic Blowdown with additional Manual Drain Valve and Electronic Spark Ignition. For each cooking compar Mode and Cold Water Condenser. Type 304 Stainless Steel cooking com­partment.
tment: 60 minute Mechanical T
p ON/OFF Steam Switch only for compartment controls (MC) p Cafeteria pans in depths of 1˝, 21⁄2˝, 4˝ and 6˝
f Kit (GPTO), Kettle Interconnecting Kit (IMK-)
ake Of
p Power
T
p Correctional Packages p Stainless Steel Base Frame (FSS) p Stainless Steel Insulated Flue Cover (SSF) p Quick Disconnect for gas line (QDC) p Secondary Low W
AR. CA. CO. CT
(Required for NE. NV
AZ.
. NM. NC. OK. OR. PR. RI.
ater Cut-Of
f, factory installed (CALG)
. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT
A. WA. WV., Buffalo, NY, Wash. DC)
. V
TN. UT
p Compartment Door Steam Shut Of p Boiler Descaling Pump Kit (107142) p Water Filters p Rear Gas Connection (RGT)
, Manual Operation
imer
f Switch (SCS)
.
p Right Hand Door Hinging, Controls on the Left (DHR) p Electronic
Timer with Compensating Load Feature (ETC)
SECT. III PAGE 3
0707
ALLOW 6.00" MIN CLEARANCE
FROM REAR AND SIDES IN
ON-COMBUSTABLE LOCATIONS
N
Each compartment has capacity for:
Three, 12˝ x 20˝ x 21⁄2˝ or six, 12˝ x 20˝ x 1˝ deep
C
afeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of u
se per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
Right - 6”, Left - 6”, Rear - 6” on control side if adjoining wall or equipment is over 30” high for service acess)
1 1/2” NPT common drain. Do not connect other units
5.0 Amps
TES
NO
:
Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA (AGA, CGA).
to this drain. Do not use PVC pipe for drain.
For use in non­combustible locations.
Contact factory for
ariances to c
v
(12”
learances.
SECT
O SCALE)
T
(NOT
.
III P
Litho in U.S.A.
AGE
4
0707