STEAMCRAFT®GENERATOR STYLE
HIGH SPEED CONVECTION STEAMERS
M
T
SteamCraft®Gemini
SHORT SERIES PRESSURELESS STEAMER,
TWIN, INDEPENDENT GAS-FIRED GENERATORS
Cleveland Standard Features
I
I
4.5” (1385mm) height to top of upper compartment
5
(lower height makes maintenance easier by lowering the descaling ports)
II
Each compartment has cooking capacity for 3 each
12˝ x 20˝ x 2
I
I
Doors hinged left and the controls on the right
I
I
High efficiency independent Power Burner Steam Generators
50,000 BTU's for each compartment
II
Each steam-cooking compartment is independently operated
and controlled by a separate stainless steel steam generator,
gas valve, Power On/Off Control Levers and a Exclusive,
Remote Probe-Type Water Level Control
II
Easy Access Cleaning Port: Each generator has a deliming port
located on the outside, top of the unit
Generator Cleaning Light for each compartment warns the oper-
II
ator to delime generator
II
Generator Steam Standby Mode: Holds generator at a
steaming temperature, allows unit to start cooking quickly
II
Each compartment has one, 60-Minute Electro-Mechanical
Timer with "SureCook" load compensating feature.
Manual Bypass Switch for constant steaming.
II
Durable 14 Gauge, 304 Stainless Steel construction for
compartment door, cooking cavity and steam generator
II
Exclusive Gemini Drain/Power Control System:
Manual 1/2 inch "Ball Valve" type drain that controls main power
On/Off and automatically fills generator (located on the control
panel)
II
Exclusive Brass Steam Jets distribute steam even throughout
cooking compartment
II
Easy, Front -Access Generator Controls comes with a pullout
drawer for simple servicing of unit
II
6˝ Stainless Steel Adjustable Legs with Flanged Feet
II
Approvals: CSA (AGA, CSA) and U.L/NSF#4
II
Compartment Steam Shut-Off Switch when compartment door is
opened
1
⁄2˝ Steam Table Pans
6
MODEL: 24CGA6.2S
Short Form Specifications
Cleveland
Two compartment steamer. Independent steam generators
BTU's input per compartment.
with load compensating feature. Gas valve and water level control
system. Exclusive remote probe-type water level controls.
Exclusive Brass “Steam Jet” distribution system. Two-piece freefloating compartment door. 14 gauge stainless steel cavity and
door. Pullout service drawer for controls and Gemini Drain/Power
Control System.
Ë Propane Gas (PG)
Ë Dissolve
markings (106174)
Ë Water Filters
SteamCraft
®
Descale Solution, 6 one gallon container w/quart
TM
Gemini
Model 24CGA6.2S, 54.5" high,
"SureCook" electro mechanical timer
, 50,000
Options & Accessories
Ë Electronic Timer with Compensating Feature (ETC)
Ë On/Off Steam Switch Controls, no timer (MC)
SECT. IV PAGE 11
1007
20.63"
(524mm)
33.13"
(842mm)
4.87"
(124mm)
3.00" TYP
(76mm)
7.75"
(197mm)
10.44"
(265mm)
5.00"
(127mm)
4.00"
(102mm)
12.00"
(305mm)
24.00"
(508mm)
12.76"
(324mm)
15.06"
(383mm)
17.43"
(
443mm)
37.13"
(943mm)
13.25"
(337mm)
10.00"
(254mm)
2
0.88"
(530mm)
4.75"
(121mm)
13.88"
(353mm)
20.36"
(517mm)
17.25" TYP
(438mm)
21.50"
(546mm)
59.21"
(1504mm)
30.25"
(768)
5.00"
(127mm)
7.34"
(186mm)
20.50"
(521mm)
2.06"
(52mm)
6.60"
(168mm)
33.13"
(842)
6.13"
(156mm)
24.00"
(610mm)
OPERATING
CLEARANCE
S
ECONDARY
CLEARANCE
C2
D
C
1
WATER QUALITY
REQUIREMENTS
The quality of water varies
greatly from region to
region. Steam equipment
generators must be
drained daily and chemically descaled periodically
o ensure proper operation.
t
To minimize service problems caused by the accumulation of minerals and
chemicals in water review
the following quality guidelines with a local water
treatment specialist. Inlet
water that is beyond these
specified guidelines should
be treated to achieve these
acceptable limits. Total
Dissolved Solids less than
60 ppm, Alkalinity less than
20 ppm, Silica less than 13
ppm, pH factor greater
than 7.5, Chlorine less
than 30 ppm.
Each Compartment has
Capacity for:
• Three 2
1
⁄2˝ x 12˝ x 20˝
Steam Table Pans
• Six 1˝ x 12˝ x 20˝
Steam Table Pans
• Two 4˝ x 12˝ x 20˝
Steam Table Pans
GAS ELECTRIC COLD WATER CLEARANCE DRAINAGE
11⁄4˝ IPS line size, 3⁄4˝ connection 120V-1Phase, 60 Hz. 35 psi minimum RIGHT = 12.00˝
NATURAL PROPANE BTU 2 Blowers & Controls 60 psi maximum LEFT = 3.00˝
3
Piping
⁄4˝ N.P.T. Piping 3⁄4˝ N.P.T. 50,000 each 150 watts each C2 3⁄8˝ dia. NPT for Generator REAR = 3.00˝
Supply pressure Supply pressure Generator, C1
4.50˝ W.C. Min. 11.00˝ W.C. Min. 100,000 total
14.00˝ W.C. Max. 14.00˝ W.C. Max.
Manufacturer must be notified if unit will
be used above 2,000 feet
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).
** Do not connect to GFI
outlet. See note below.
3
⁄8˝ dia. NPT for Condenser Allow 6˝ space min.
Right - 3”, Left - 3”,
Rear - 3”
(12” on control side if
adjoining wall or
equipment is over 30”
high for service access)
from rear and sides
Contact factory
When located near
for variances to
combustible walls
clearances.
D
11⁄2˝ dia.
Do not connect other units to this
drain
Drain must not be located
beneath the steamer itself
Preferred floor drain location
should be a minimum distance
(from the unit) of at least 12” from
the left side, 12" from the right
side, 6” from the front and 6" from
the rear
Do not use PVC pipe
(NOT TO SCALE)
SECT. IV PAGE 12
Litho in U.S.A.