STEAMCRAFT®GENERATOR STYLE HIGH SPEED CONVECTION STEAMERS
SteamCraft®GeminiTM10
TWO COMPARTMENT FLOOR MODEL DESIGN PRESSURELESS CONVECTION STEAMER TWIN, INDEPENDENT GAS-FIRED GENERATORS
Cleveland Standard Features
II
Cooking Capacity for up to ten 12˝ x 20˝ x 2 1/2˝ deep Cafeteria Pans, five each compartment.
I
I
Totally independent cooking compartments, each has its' own generator, gas valve and water level controls - no shared com­ponents
I
I
Exclusive High Efficiency Gas Power Burner (forced air) Generator: Produces more steam for faster cooking while low­ering operating costs (72M BTU's per compartment)
II
Easy Access Cleaning Port: Each generator has a deliming port located on the outside, top of the unit
II
Generator Cleaning Light for each compartment warns the operator to delime generator
II
Generator Steam Standby Mode: Holds generator at a steaming temperature, allows unit to start cooking quickly
II
Each compartment has one, 60-Minute Electro-Mechanical Timer with "SureCook" load compensating feature. Manual Bypass Switch for constant steaming.
II
Durable 14 Gauge, 304 Stainless Steel construction for compartment door, cooking cavity and steam generator
II
Exclusive Two-Piece Compartment door: Slammable, self-adjusting door provides and airtight seal, reversable door gasket for extended life
II
Exclusive Gemini Drain/Power Control System: Simple, reliable 1/2" ball valve style drain automatically turns power ON/OFF
II
Exclusive Brass Steam Jets distribute even-high velocity steam throughout cooking compartment for faster cooking times
II
Easy, Front -Access Generator Controls comes with a pullout drawer for simple servicing of unit
II
6˝ Stainless Steel Adjustable Legs with Flanged Feet
II
Approvals: CSA (AGA, CSA) and U.L/NSF#4
II
Compartment Steam Shut-Off Switch when compartment door is opened
Options & Accessories
MODEL: 24-CGA-10.2
Short Form Specifications
Shall be Two Compartments, Cleveland Convection Steamer series
SteamCraftGeminiTM10
Steam Generator, 72M BTU's input per compartment.
generator, gas valve and water level control system.
Generator Blowdown. Steam Generator with Automatic Water Fill on start
Exclusive remote probe-type water level controls. Exclusive
up.
Brass “Steam Jet” distribution system. Two-piece free-floating compartment door.
partments.
Drain/Power Control System.
Choice of Compartment Controls. Manual By Pass for continuous steaming.
Pullout service drawer for controls and Gemini
Ë Propane Gas (PG)
®
Ë Dissolve
Descale Solution, 6 one gallon container w/quart
markings (106174)
Ë Water Filters
, Model 24-CGA-10.2, Twin Gas Atmospheric
Independent steam
Automatic
Type 430 Stainless Steel exterior and cooking com-
Exclusive Cold Water Condenser design.
Ë Electronic Timer with Compensating Feature (ETC)
Ë On/Off Steam Switch Controls, no timer (MC)
SECT. IV PAGE 13A
0810
C
Each Compartment has capacity for:
1
• Five, 12˝ x 20˝ x 2
2˝ deep
Cafeteria Pans.
WATER QUALITY REQUIREMENTS
The quality of water varies greatly from region to region. Steam equipment generators must be drained daily and chemically descaled periodically to ensure proper operation. To minimize service problems caused by the accumulation of minerals and chemicals in water review the following quality guidelines with a local water treatment specialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than 7.5, Chlorine less than 30 ppm.
A B C
GAS ELECTRIC COLD WATER CLEARANCE DRAINAGE
11⁄4˝ IPS line size, 3⁄4˝ connection 120V-1Phase, 60 Hz. 35 psi minimum RIGHT = 3˝ operating,
NATURAL PROPANE BTU 2 Blowers & Controls 60 psi maximum 12˝ if adjoining wall or
3
Piping
⁄4˝ N.P.T. Piping 3⁄4˝ N.P.T. 72,000 each 150 watts each LEFT = 3˝
Supply pressure Supply pressure Generator, One (E) 3/8" dia. REAR= 3˝
4.50˝ W.C. Min. 11.00˝ W.C. Min. 144,000 total
14.00˝ W.C. Max. 14.00˝ W.C. Max.
** Do not connect to GFI
outlet. See note below.
NPT for Generator Allow 6˝ space min.
One (D) 3/8" dia when located near
Manufacturer must be notified if unit will NPT for Condenser combustible walls be used above 2,000 feet
DE
Right - 3”, Left - 3”, Rear -3”
(12” on control side if adjoining wall or equipment is over 30” high for service access)
Contact factory for variances to clearances.
11⁄2˝ dia.
Do not connect other units to this drain
Drain must not be located beneath the steamer itself
Preferred floor drain location should be a minimum distance (from the unit) of at least 12” from the left side, 12" from the right side, 6” from the front and 6" from the rear.
Do not use PVC pipe
D
s
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).
(NOT TO SCALE)
SECT. IV PAGE 14A