STEAMCRAFT®GENERATOR STYLE HIGH SPEED CONVECTION STEAMERS
SteamCraft®Ultra 10 D
TWO COMPARTMENT FLOOR MODEL DESIGN PRESSURELESS CONVECTION STEAMER DIRECT STEAM, 24˝ WIDE DESIGN
Cleveland Standard Features
n Cooking Capacity for up to ten 12˝ x 20˝ x 2
Cafeteria Pans.
n Durable 14 Gauge Stainless Steel Construction:
For compartment door, cavity and front.
n One 60 Minute Electro-Mechanical Timer and Switch
for manual operation.
completion.
n Separate Switch for Power “on/off.”
n Exclusive Steam Cooking Distribution System: Exclusive
Brass Steam Jets produce a high velocity convection steam without fans. Coved Corner design in cooking compartment distributes heat evenly, and is easy to keep clean. Creased top & bottom enhance drainage. Cold Water Condenser for each compartment maintains a dry steam. Fully insulated cooking compartment for thermal efficiency. Removable Stainless Steel Slide Racks.
n Exclusive “Cool to the Touch” Compartment Door
Design:
provides an air tight seal. Stainless Steel Slam/Latch Door Latch mechanism for reliability.
n Condensate Drip Trough: Provided under lower
compartment door to collect condensate.
n Left Hand Door Hinging: Compartment Doors hinged left,
control on the right.
n Moisture Separator f
n Pressure reducing Valve or 20-50 psi steam supply
pressure, based on a
n Single Cold water Connection.
n NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
n Standard voltage for controls: 115 volts, 60 Hz. single
phase.
4
o Clean non-toxic, uncontaminated steam is required for all
“Direct Steam” steamers.
Free floating inner door with reversible door gasket
Audible signal for cooking time
or incoming steam.
3
4˝ line size.
Options & Accessories
1
2˝ deep
MODEL: c 24-CDP-10
Short Form Specifications
Shall be CLEVELAND, Direct Steam Floor Model Steamer, Model 24-CDP-10, single, large capacity Pressureless Convection Steamer. Choice of Compartment Controls, Manual By Pass Operation Mode, Compensating Thermostat, Exclusive Cold Water Condenser design, Type 430 Stainless Steel exterior and cooking compartments.
p Right Hand Door Hinging, Controls on the Right (DHR) p Electronic Timer with Compensating Load Feature (ETC) p ON/OFF Steam Switch only for compartment controls (MC) p 10˝ Stainless Steel Legs (LF10) p Compartment Door Steam Shut Off Switch (SCS) p Cafeteria Pans in depths of 1˝, 21⁄2˝, 4˝
and 6˝
p Water Filters p Correctional Packages
SteamCraftUltra 10
, two compartments,
p Second Pressure Reducing Valve for 50-120 psi steam
pressure. (PRV)
SECT. IV PAGE 21
0707
C
C
Each Compartment has capacity for:
• Five, 12˝ x 20˝ x 2 afeteria Pans.
C
1
2˝ deep
WATER QUALITY REQUIREMENTS
he quality of water varies
T greatly from region to region. Steam equipment generators must be drained daily and chemically descaled periodically to ensure proper operation. To minimize service problems caused by the accumulation of minerals and chemicals in water review the following quality guidelines with a local water treatment specialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than 7.5, Chlorine less than 30 ppm.
CITY
AL CAP
T
O
T
10 — 12˝ x 20˝ x 21⁄2˝ Cafeteria Pans or
20 — 12˝ x 20˝ x 1˝ Cafeteria Pans or
26 — 12˝ x 20˝ x 4˝ Cafeteria Pans
Steam supply:
Furnish 20 to 50 psi minimum required.
For pressures between 50 to 120 psi, on additional Pressure Reducing Valve must be specified.
TES
NO
Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, ULC and UL/NSF#4.
A
(2 Compar
DIRECT STEAM COLD WATER DRAINAGE
3
4˝ IPS minimum line.
:
tments)
UTILITY CONNECTIONS
Electrical Supply Drain: 1.50˝ Dia.
A
ater Supply for Condenser
W
B
Steam Supply: 0.75˝ Dia.
C
3
⁄8˝ Dia. NPT
D
ELECTRIC
115V - 1 Phase
Controls - 51 Watts
35 psi minimum 60 psi maximum
3
4˝ Dia. NPT for
Condenser
D
1
2˝ Dia.
1
Do not connect other units to this drain.
Drain must not be located beneath the steamer itself.
No PVC pipe for drain.
CLEARANCE
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoining wall or equipment is over 30” high for service access)
Contact factory for variances to clearances.
(NOT TO SCALE)
SECT. IV PAGE 22
0707