STEAMCUB™ BOILERLESS
CONNECTIONLESS STEAMER
SteamCubTMPlus
PRESSURELESS STEAM COOKER,
RETHERMALIZER & HOLDING CABINET
Cleveland Standard Features
n B
oilerless Pressureless Steam Cooker, Holding Cabinet and
Rethermalizer.
n Capacity: Full Size Steam Table Pans:
• Five: 2 1/2" x 12" x 20" (1/1 GN, 65mm)
• Ten: 1" x 12" x 20" (1/1GN, 40mm)
n Easy installation, no drain line, water connections or hood is
needed.
n Programmable Preheat and Holding Cycle Temperature
Controls with Compensating Thermostat.
•
• Digital Time-Temperature and Low Water Indicator Display
n Three Versatile Operating Modes.
• Steam and Hold
• Holding Only: Preset at 160˚ F (71˚ C)
• Constant Steaming
n 6" (152mm) Skid Resistant Stainless Steel
with Flanged Feet.
n 8 gauge stainless steel inner cooking compartment, 14
gauge stainless steel outer compartment with two piece
compartment door for an airtight, leak-proof seal.
n 9 kW total output, with easy to remove 1 kW heating
elements (9ea) cast into aluminum bocks.
n Electronic Low-Water Shut-Off Safety Indicator with audible
alarm, High
Indicator Light.
n Separate Power ON/OFF Control includes an Automatic Pre-
Heat when power is turned "ON".
n Easy-Access Manual Drain Valve located in front, Pan Slide
Guides located under unit to fit 12" x 20" (1/1GN) Pans.
Includes one 4" x 12" x 20
n Approvals: cUL, NSF #4.
*
Timer settings for 10 minute, 1 minute or 10 second intervals
Adjustable Legs
emperature Safety Shut-Of
T
f and LED "Heat On"
MODEL: c 1SCE
Short Form Specifications
Shall be a Cleveland SteamCub Plus™ , Model 1SCE, one compartment
counter top steamer, holding cabinet and rethermalizer model number 1SCE.
Electronic controls with three operating modes: constants steaming, steamhold and holding only. 9 kW, 208 volts, 3 phase. Audible low water and high
temperatur
ment, 14 gauge stainless steel outer compartment with two piece compartment door
e safety indicator
.
.
8 gauge stainless steel inner cooking compar
-
t
Options & Accessories
p Equipment Stand Model UniStand34.
p POSK Pull-Out Shelf Kit for UniStands (P/N 111724)
p URK Pan Rack Kit UniStands (P/N 111726)
p Optional Voltages, 480 Volt (VOS2).
p 6 kW total Output Six - 1kW heating elements.
p Single Phase Operation.
* Consult local authorities for venting requirements
SECT. I PAGE 3
0707
17.434"
4
43mm
2
1.625"
549mm
2
3.100"
587mm
25.361"
644mm
2.100"
53mm
2
4.858"
631mm
1.574"
40mm
30.890"
785mm
1.500"
38mm
RIGHT
SIDE VIEW
FRONT
VIEW
REAR
VIEW
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether
untreated or pre-treated, based upon 10 hours of use per day,
and a Daily Blowdown, are as follows:
OTAL DISSOLVED SOLIDS less than 60 parts per million
T
OTAL ALKALINITY less than 20 parts per million
T
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water
analysis for recommendations concerning steam generator
feed water treatment (if required), in order to remove or
reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of
the steam generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable for the
generator.
Compartment has capacity for:
•
Five, 12˝ x 20˝ x 2
1
⁄2˝ deep Cafeteria Pans.
ELECTRICAL
WATTS VOLTS PHASE WIRES
CYCLE
HERTZ WIRE SIZE (COPPER)*
AMPS
Standard Wattage
Three Phase - 9 kW Standard
9400 208 3 3 60 26.1 10
9400
240
3
3
60
9400 480 3 3 60 11.4 14
Optional Low W
Three Phase - 6 kW option
6400 208 3 3 60 17.8 12
attage
6400 240 3 3 60 15.4 12
6400 480 3 3 60 7.7 14
* For supply connection use only copper wire suitable for at least 75˚C. (167˚F).
Note: Consult local authorities for venting and installation requirements.
∗
For supply connection use only copper wire suitable for at least 75
TES
NO
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are
SUPPLY CONNECTION
22.6
10
WATTS VOLTS PHASE WIRES
Standard Wattage
Single Phase - 9 kW Standard
9400 208 1 2 60 45.2 6
9400
Optional Low W
Single Phase - 6 kW option
6400 208 1 2 60 30.8 8
6400 240 1 2 60 26.7 10
C (167
°
240
1
2
attage
°F).
U.L/NSF#4 and CSA (AGA, CGA).
CYCLE
HERTZ WIRE SIZE (COPPER)*
AMPS
60
SUPPLY CONNECTION
39.2
8
O SCALE)
T
(NOT
.
SECT
I P
Litho in U.S.A.
AGE
4