Cleveland Motion Controls ULTRA SERIES CANTILEVER TRANSDUCER CLTSCM User Manual

MODELS: CLTEC, CLTSC, CLTECM
7550 Hub Parkway Cleveland, Ohio 44125 Phone: 216.524.8800 Fax: 216.642.2131 www.CMCcontrols.com
INSTRUCTION MANUAL
(MAN-70252)
®
C
LEVELAND-KIDDER
& CLTSCM
REVISION
AA
Industrial Products Division
ULTRA SERIES CANTILEVER TRANSDUCER MAN-70252 REV. AA
REVISION HISTORY
Rev ECO Author Date Description of Change
AA XXX RDL 1/27/2005 As Released
PAGE 2 OF 18
MAN-70252REV. AA ULTRA SERIES CANTILEVER TRANSDUCER
TABLE OF CONTENTS
1 IMPORTANT INFORMATION.........................................................................5
1.1 ORDER NUMBERS ........................................................................................................... 5
1.2 CONTACT INFORMATION AND SERVICE ASSISTANCE ..........................................................6
1.3 RECEIVING AND UNPACKING ............................................................................................ 6
1.4 PRE-INSTALLATION PRECAUTIONS....................................................................................7
1.4.1 Shipping..................................................................................................................7
1.4.2 Roll Balance............................................................................................................ 7
1.4.3 Critical Roll Speed...................................................................................................7
1.4.4 Avoiding Damage to the Transducer....................................................................... 7
1.4.5 Excitation Voltage...................................................................................................7
2 SPECIFICATIONS.......................................................................................8
2.1 FORCE RATINGS .............................................................................................................9
2.2 BEFORE INSTALLING THE TRANSDUCER............................................................................9
2.2.1 Installation Precautions...........................................................................................9
2.2.2 Safety Considerations.............................................................................................9
2.2.3 Mounting Configurations.......................................................................................10
2.2.4 Mounting Hardware and Fastener Torque Recommendations .............................. 11
2.2.5 Mounting Dimensions............................................................................................12
3 INSTALLING THE CANTILEVERED TRANSDUCER.......................................... 13
3.1 MOUNTING THE TRANSDUCER........................................................................................ 13
3.2 MOUNTING THE SENSING ROLL......................................................................................14
3.3 ORIENTING THE CANTILEVER TRANSDUCER.................................................................... 14
3.4 CHECKING THE TRANSDUCER MOUNTING .......................................................................15
3.5 ELECTRICAL CONNECTIONS AND WIRING ........................................................................15
3.6 MATING CONNECTORS ..................................................................................................15
3.7 CALIBRATION ................................................................................................................ 16
4 TROUBLE SHOOTING...............................................................................17
4.1 DC RESISTANCE CHECK................................................................................................18
4.2 DC VOLTAGE AND CURRENT CHECKS ............................................................................ 18
PAGE 3 OF 18
ULTRA SERIES CANTILEVER TRANSDUCER MAN-70252 REV. AA
WARRANTY
Cleveland Motion Controls warrants the goods against defects in design, materials and workmanship for the period of 12 months from the date of delivery on the terms detailed in the Cleveland Motion Controls, Inc. Terms and Conditions of Sale, document number AO-90131
Cleveland Motion Controls, Inc. reserves the right to change the content and product specification without notice.
© 2005 in this document is reserved to: Cleveland Motion Controls, Inc. 7550 Hub Parkway Cleveland, OH 44125 216-524-8800 Phone 216-642-2199 Fax
INTENDED USERS
This Instruction Manual is to be made available to all persons who are required to configure, install or service the equipment described in this manual or any other related activity.
ADDITIONAL INFORMATION
ATTENTION: The following information is provided merely as a guide for proper installation. Cleveland Motion Controls cannot assume responsibility for the compliance (or failure to comply) to any code (national, local or other) that prescribes the proper installation of this electro-mechanical device or associated equipment. A hazard of personal injury and/or property damage can exist if applicable codes are not adhered to.
CE EMC RESPONSIBILITY
The Cleveland-Kidder Ultra Transducer may be used by a manufacturer as a component of a larger system, along with other components, which may or may not bear the CE mark. The system assembler is responsible for the compliance of the system as a whole with the EMC Directive.
Before installing the Transducer you must clearly understand who is legally responsible for conformance with the EMC Directive. Misappropriation of the CE mark is a criminal offense.
PAGE 4 OF 18
MAN-70252REV. AA ULTRA SERIES CANTILEVER TRANSDUCER
1 IMPORTANT INFORMATION
1.1 ORDER NUMBERS
Use the following example and Tables A, B and C to determine order numbers for:
Ultra Series Transducers
Mounting Ki ts
Shaft Adapter
Figure 1 – Example for Determining Transducer, Mounting Kit and Shaft Adapter Order Numbers
If you needed to Purchase a Transducer, Mounting Kit and Shaft Adapter corresponding to following description:
Size 2 cartridge body.
Side connection (to allow flange mounting).
Maximum Working Force (MWF) of 100 lbs.
Shaft Adapter to accommodate 1 inch (outside diameter)
shaft
Then, you would use Catalog Numbers:
Ultra Series Transducer = MO-13458-00 (Refer to Table A) Mounting Kit = MO-04498 (Refer to Shaft Adapter = MO-12145-1 (Refer to
Table B)
Table C)
Having the following information at hand will help you to easily determine which of the Ultra Series Cantilevered Transducers is right for your application:
The desired diameter of the shaft bore
The type of electrical connection
Maximum wor k in g for c e
Use Table A to determine the catalog number for the proper Cantilevered Transducer.
Table A – Determining a Catalog Number for the Ultra Cantilevered Transducer
English
Cartridge Size
1T ALUM MO-13453 MO-13454 0.1 lb. 1 lb. 5 lb. 10 lb. 1T STEEL MO-13455 MO-13456 25 lb. 50 lb. 100 lb. 2T STEEL MO-13457 MO-13458 100 lb. 250 lb. 500 lb.
Metric
Cartridge Size
1T ALUM MO-13459 MO-13460 0.5 N 5 N 20 N 45 N 1T STEEL MO-13461 MO-13462 100 N 200 N 450 N 2T STEEL MO-13463 MO-13464 450 N 1000 N 2000 N
End
Connector
(CLTEC)
End
Connection
(CLTECM)
Side
Connector
(CLTSC)
Side
Connection
(CLTSCM)
Order Code Suffix, M.W.F.
-00 -10 -20 -30
Order Code Suffix , Metric M.W.F
-00 -10 -20 -30
PAGE 5 OF 18
ULTRA SERIES CANTILEVER TRANSDUCER MAN-70252 REV. AA
Table B – Determining a Mounting Kit Catalog Number for the Ultra Series Cantilevered Transducer
Mounting Style
Bearing (BR) Flange (FL) Pillow Block (PB)
Table C – Determining a Shaft Adapter Catalog Number for the Ultra Series Cantilevered Transducer
If Finished Bore Diameter (nominal I.D) equals:
1/2 inch MO-12143-0 MO-12144-0
5/8 inch MO-12143-1 MO-12144-1 3/4 inch MO-12143-2 MO-12144-2 MO-12145-0 1 inch MO-12143-3 MO-12144-3 MO-12145-1 1-1/8 inches MO-12143-4 MO-12144-4 MO-12145-2 1-1/4 inches MO-12143-5 MO-12144-5 MO-12145-3 1-1/2 inches MO-12145-4
17 millimeter MO-12146-0 MO-12147-0 20 millimeter MO-12146-1 MO-12147-1 MO-12148-0 25 millimeter MO-12146-2 MO-12147-2 MO-12148-1 30 millimeter MO-12146-3 MO-12147-3 MO-12148-2 35 millimeter MO-12148-3
1T (inch) 2T (inch) 1T (millimeter) 2T (millimeter)
MO-04495 MO-04500 MO-05175 MO-05174 MO-04493 MO-04498 MO-05176 MO-05177 MO-04494 MO-04499 MO-05172 MO-05173
1T Alum
Use Catalog
number:
Size
1T Steel
Use Catalog
number:
1.2 CONTACT INFORMATION AND SERVICE ASSISTANCE
2T Steel
Use Catalog
number:
For service assistance, have the following information available:
Type of Cartridge Transducer you are using
Maximum wor k in g for c e
Purchase order number
You can contact Cleveland Motion Controls at:
Phone: Fax:
216.524.8800
216.642.5155
For the latest product information, technical literature etc., visit our website at www.cmccontrols.com
Disassembly by improperly trained personnel may result in additi onal damage to t hese units. Should repairs be required or for warranty repairs, contact the Customer Service Department for a return authorization number before returning the units.
1.3 RECEIVING AND UNPACKING
After receiving the Ultra Cantilever Transducer you should:
Carefully, unpack and inspect the equipment
Compare the received shipment with the packing list
Report any damage to the carrier and your CMC representative
Store equipment that will not be used in a clean, dry location
Take appropriate precautions to prevent moisture, dust and dirt from accumulating in storage and
installation areas
PAGE 6 OF 18
Loading...
+ 12 hidden pages