Cleveland Motion Controls MO-13829 User Manual

Current Regulator
PowerBlock2
Current to EMAG Brakes
Schematic diagram :
Freewheel mode
µP
Set Point
Freewheel mode: Load is electrically decoupled and allowed to move freely
Holding Mode: Load is restrained from movement to the full capability of the unit, as defined by the Max Current Adjustment (switches S1, S2 and S3)
Holding
mode
Shunt
(real time
current value)
+
Brake/Clutch
Supplies and Regulates
and Clutches
Technical features:
Input voltage [ V ] 24 AC / DC
Max output current [ A ] 2
Output load (resistance) [ ohm ] 4 - 20
Max power consumption [ VA ] 70
Remote voltage control [ V ] 0 - 10 DC
Ambient temperature [ ° F ] +10 ... +40
Weight oz. 6
Benefits :
MO-13829
Dimensions :
105
57
45
100
DIN rail
fixing (35)
Regulated current power supply based on microcontroller technology
High level of protection against transients (short-circuit & circuit opening)
Remote control via potentiometer or analog 0 to 10V input
Freewheel and Holding modes selected from external contacts or analog voltages
Selected mode status shown by front face LED’s
Real time Current equivalent voltage output available
Plug-in connectors
Compact enclosure with integrated DIN rail mount
CE - CEM compatible
Electrical Information:
Connections
C1 / C2 Brake/Clutch Com 0 V Amp Real time current equivalent voltage
(1.00 A 1.00 V)
Test Internal fuse test points (When OFF, measure of 10K
ΩΩ
between the two (2) points (*) means that the fuse is OK
Com Equipotential supply point (when grounding the transformer secondary)
24 V Input Power : 24 V AC or 24 V DC SetP Set point input (0 10 V DC) 10 Set point potentiometer supply (10 k
ΩΩ
)
V+ Logic inputs voltage
Free Logic input “Freewheel” mode Stop Logic input “Holding” mode
Front face LED’s L1 Power ON L2 Freewheel mode active L3 Holding mode active
Switches S1 S2 S3 Max current adjustment
(from 0.25 to 2.00 A, for set point input = 10 V)
Note :
- The equipotential point is available on terminal “Com” of the supply terminals
- When grounding the secondary of the transformer, refer to the Transformer Grounding diagram above
PowerBlock2
MO-13829
Brake/ Clutch
0V
+24 V AC / DC
A1 =V1
10 k
0 - 10 V
0V
+24 V
+24 V
tseT e
s uF
1 C
2 C
moC
pm
A
tseT
V42
Pte
S
V0 1
+V
eerF
+V
po tS
moC
mo C
m o C
m oC
L1
L2
L3
Switches
*
*
Max. Output current
adjustment
Off On
0.25
0.50
0.75
1.00
Off On
1.25
1.50
1.75
2.00
24V
Com
Secondary
POWER
CURRENT SCALING
FREEWHEEL
HOLDING
Primary
©Cleveland Motion Conrols, Inc.
7550 Hub Parkway • Cleveland, Ohio 44125
ph: 216.524.8800 or 800.321.8072 • fax: 216.642.2199
www.cmccontrols.com • email: literature@cmccontrols.com
Transformer Grounding diagram
# AO-70321 7/04