Cleveland SGL-T Installation Manual

INSTALLATION, OPERATION AND REPAIR MANUAL
MODEL #
SGL-T
SGM
SE95001
GAS SKILLET
CLEVELAND RANGE INC
1333 East 179th St. Cleveland, Ohio U.S.A. 44110
(216) 481-4900
9111 REV:0
- -IF YOU SMELL GAS - -
FOR YOUR SAFETY
APPLIANCE.
DO NOT STORE OR USE GASOLINE OR ANY OTHER FLAMMABLE LIQUIDS AND VAPOURS IN THE VICINITY OF THIS OR ANY OTHER
2. DO NOT TOUCH ELECTRICAL
SWITCHES.
3. EXTINGUISH ANY OPEN
FLAME.
4. CALL YOUR GAS SUPPLIER
IMMEDIATELY.
IMPORTANT
THE FOLLOWING POINTS ARE TO ENSURE THE SAFE INSTALLATION AND OPERATION OF THIS EQUIPMENT :
ENSURE ALL GAS AND ELECTRICAL SUPPLIES MATCH RATING PLATE AND ELECTRICAL STICKERS
OBSERVE ALL CLEARANCE REQUIREMENTS DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE APPLIANCE BEFORE CLEANING OR
SERVICING UNIT
1. OPEN WINDOWS.
ONLY A QUALIFIED SERVICE TECHNICIAN SHOULD REPAIR UNIT
THE INSTALLATION AND CONNECTION MUST COMPLY WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH CAN1 B149 INSTALLATION CODE OR WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.1-1988.
POST IN A PROMINENT LOCATION, INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
THE APPLIANCE AND ITS INDIVIDUAL SHUT OFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 1/2 PSIG. (3.45 KPA).
THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING ITS INDIVIDUAL MANUAL SHUT OFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG. (3.45 KPA).
RETAIN THIS MANUAL FOR YOUR REFERENCE.
422-01TE
1
GENERAL INFORMATION
The serial plate is located on the left hand box cover. Remove front lift off cover for access. Gas type, burner ratings and electrical requirements are stated on the plate.
1. Damage check: always check carton or crate for possible damage incurred in shipping. After carefully uncrating, check for "concealed" damage. Report any damage immediately to your carrier.
2. 208/240 volt units are equipped with a circuit breaker. Should it be necessary to reset the breaker, the reset button is located in the center of the right control box. Remove front panel for easy access.
regulator which is installed on the manifold. For easy access to the pressure regulator, view along left side of unit from underneath.
Once pressure test is completed, turn power switch and thermostat to the "OFF" position and replace control box cover using self tapping screws removed earlier.
5. Have a qualified gas technician check the gas pressure to make certain that existing gas facilities (meter, piping, etc.) will deliver the BTU's of gas required at the unit with no more than 1/2" water column pressure drop. When checking pressure, be certain that all the equipment on the same gas line is turned to the "ON" Position
3. The correct type of gas for which the unit was manufactured is noted on the rating plate, and this type of gas must be used.
4. A pressure tap is supplied with the unit just before the pilot solenoid valve which is installed on the manifold. The gas pressure must be checked when unit is installed, to ensure unit gas pressure is the same as specified on rating plate. For access to the pressure tap, remove front panel, turn power switch to the "OFF" position as a precaution, and remove the two self tapping screws which secure the left control box cover. Turn power switch and thermostat to the "ON" position (using extreme caution) and complete pressure test.
If necessa ry, pressure adjustments can be made at the pressure
6. Make certain that new piping joints and connections have been made in a clean manner and have been purged, so that piping compound, chips, etc., will not clog pilots, valves, and/or controls. Use pipe joint sealant that is approved for use with liquefied petroleum gas.
7. WARNING: Always check gas connections for leaks using soap solution or like means. DO NOT CHECK WITH OPEN FLAME.
INSTALLATION CLEARANCES
This unit must be installed in accordance with the following clearances in order to provide proper operation and servicing of the appliance. Also, it is recommended that unit be installed with sufficient clearances to provide for proper cleaning and maintenance. Minimum clearances are 1" for the
sides and 6" from back.
2
422-02TE
INSTALLATION
1. Carefully remove unit from carton or crate.
Remove any packing material from unit. On stainless steel panels, the protective material should be removed before the unit is installed.
2. Set skillet in position where gas and electrical services are nearby. Comply with clearances stated on the specification sheet. Ensure there is sufficient clearance between fry pan and back wall Check for overhead clearance to accommodate for hinged cover when in the raised position.
For ease in attaching the supply lines there is a removable cover on the electrical housing. Feed wire through hole in the center of the electrical housing and attach to the terminal block.
IMPORTANT: This appliance must be electrically grounded in full accordance with local codes, or in the absence of local codes, with the Canadian Electrical Code C22.1 or with the National Electrical Code, ANSI/NFPA No. 70-1990 (whichever is applicable).
GAS CONNECTION
3. Level skillet by means of adjustable stainless steel feet Use a spirit level and level unit four ways; across front, back, and down left and right edges. Securely anchor the adjustable feet to the floor and seal joints with a silicone sealant
4. FOR YOUR SAFETY: Keep the appliance area free and clear of any combustible materials.
ELECTRICAL CONNECTION
A direct electrical connection is required at the terminal block located near the front side of unit. The supply line will enter through the rear (or bottom) of the skillet. Refer to specification sheet for the exact locations.
It is recommended that a sediment trap (drip leg) be installed in the gas supply line. If the gas pressure exceeds 14" water column, a pressure regulator must be installed, to provide a maximum of 14" water column gas pressure to the gas contr ol valve.
Connect the gas supply piping to the input side of the gas control valve. Location and pressure data are shown on the specification sheet. Installation must be in accordance with local codes and/or the National Fuel Gas Code ANSI Z223.1-1988 (USA) or Installation Codes for Gas Burning Appliances and Equipment CANI B149.1 and B149.2 (Canada). Use a gas pipe joint compound which is resistant to L.P. gas. Test all pipe joints for leaks with soap and water solution. Ensure that the gas pressure regulator is set for the manifold pressure indicated on the gas rating plate.
3
422-03TE
VENTILATION
A gas skillet must be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting. Proper ventilation is imperative for good operation of the appliance. The ideal method of ventilating a gas skillet is the use of a properly designed ventilating canopy, which should extend at least 6" (152mm) beyond all sides of the appliance (except against a wall, if the canopy is a wall installation). This is usually part of a mechanical exhaust syst em.
Further information can be obtained by referring to the U.S.A. National Fire Protection Associations NFPA96 regulations. These standards have also been adopted by the National Building Code in Canada
AIR SUPPLY
1. It is necessary that sufficient room air ingress be
allowed to compensate for the amount of air removed by any ventilating system. Otherwise, a subnormal atmospheric pressure will occur, affecting the appliance operation adversely and causing undesirable working conditions.
2. Appliances shall be located so as not to interfere
with proper circulation of air within the confined space. All gas burners and pilots require sufficient air to operate.
3. Large objects should not be placed in front of the appliance which might obstruct the air flow through the front Do not obstruct the flow of combustion and ventilation air.
4. Do not permit fans to blow directly at the appliance, and wherever possible, avoid open windows adjacent to the appliance sides and back; also wall type fans which create air cross-currents within the room.
START UP PROCEDURE
This appliance has been factory tested and adjusted under ideal conditions but, rough handling, low gas pressure, altitude or variations in gas characteristics may require fine adjustment.
All units are equipped with fixed orifices and do not require primary air adjustment
LIGHTING INSTRUCTIONS
Ensure gas and electrical supply to the appliance, are in the "ON" position. Note: On initial light up, air must be purged from the line to achieve pi lot ignition. To light pilot, proceed as follows:
1. Turn power switch to the "ON" position.
2. Wait one minute to allow flame sensor to heat up.
3. Turn thermostat to the required temperature.
4. To shut down, turn thermostat and power switch off.
NOTE : If pilot is out, mm power switch to the "OFF" position. A 5 minute shut off period is required before relighting.
If pilot does not continue to burn after repeating the lighting instructions, mm power to the "OFF" position and have a qualified serviceman check the system.
4
422-04TE
OPERATING INSTRUCTIONS
1. Ensure gas and electrical supply to the appliance are in the "ON" position.
2. Turn power switch to the "ON" position. Pilot light will indicate power is on. Wait one minute to allow flame sensor to heat up.
3. Cleveland skillets are equipped with an electrical power tilt mechanism for ease in raising and lowering the skillet
7. If desired, once product has cooked, it can be held prior to serving at a lower temperature setting.
8. When cooking is completed, set thermostat and power switch to the "OFF" position.
9. The best time to dean the skillet is immediately after use, once skillet has cooled down. Refer to the section titled CLEANING
INSTRUCTIONS.
FOR YOUR SAFETY , this skillet is also equipped with a power interrupter which automatically shuts off the gas supply to the burners whenever the skillet is raised more than 1/2" (13mm). When released, the tilt mechanism will stop gently at any point and has a slip clutch overload protector.
IMPORTANT: Before commencing to cook, ensure skillet is in the lowered position by pressing down on the tilt switch. Ensure cover is raised first
4. To preheat, set thermostat to desired cooking temperature. Pilot light will cycle on and off with the thermostat. In the event of a high heat condition (over 450* F), the red pilot light will flash to alert the operator and the gas supply to the main burners will automatically shut off.
5. Allow skillet to preheat for approximately 15-30 minutes.
6. Once preheated, insert product in skillet and adjust thermostat to required cooking temperature.
OPERATING SUGGESTIONS
1. Turn power switch to the "OFF position when skillet is not in use.
2. Clean skillet as soon as possible after cooking.
3. Allow skillet to preheat before adding product.
4. Always lift the hinge assist before activating the tilt switch.
MAINTENANCE INSTRUCTIONS
You have purchased the finest commercial cooking equipment available anywhere. Like any other fine precision built piece of equipment it should be given regular care and maintenance.
Periodical inspections by your dealer or a qualified service agency are recommended to check temperatures, adjustments and ensure moving parts are operative. Whenever possible, avoid overheating idle equipment as this is the primary cause for increased service costs.
5
422-05TE
When corresponding with the factory or your equipment dealer regarding service problems or replacement parts, be sure to refer to the particular unit by the correct model number (including prefix and suffix letters and numbers) and the serial or code number. The rating plate affixed to the unit contains this information.
"REGULAR MAINTENANCE ENSURES PEAK PERFORMANCE."
CLEANING INSTRUCTIONS
Do not use grill stones. Heat tint can be removed by a vigorous scouring in the direction of the polish lines using SCOTCH-BRITE scouring pads or a STAINLESS scouring pad in combination with a non abrasive powdered cleanser.
4. Tomato and vinegar based products have a high add content which could attack the stainless steel finish of the skillet After cooking of such products, clean skillet interior with a baking soda and water solution. Use one tablespoon baking soda per 1 gallon of water.
A regular daily cleaning program should be followed to maintain your skillet's efficient performance and minimize servi ce calls. At the end of each day's operation, the following steps are recommended:
1. Turn power switch to the "OFF" position.
2. Skillet should be cleaned after each use, as soon as possible after cooking.
3. For general purpose cleaning, use a soft cloth with mild detergent and warm water. A sponge, non­abrasive scouring pad or a fiber brush can also be used for this purpose. To remove grease that has baked on, apply a non­abrasive cleanser to a damp cloth or sponge and rub cleanser on the metal in the direction of the polishing lines of the metal. NEVER RUB IN A CIRCULAR MOTION. Soil or burnt deposits which do not respond can usually be removed by rubbing the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINAR Y STEEL WOOL.
5. After cleaning, the skillet should be thoroughly rinsed with clean water and dried.
PILOT BURNER ADJUSTMENT
1. Ensure power switch is in the "ON" position.
2. Raise skillet high enough to observe the pilot burner flame.
3. Remove front panel
4. Turn power switch to the "OFF" position as a precaution. Remove the two self tapping screws which secure the left control box cover.
5. Turn power switch to the "ON" position in order to energize the pilot
6. Once pilot is lit turn pilot adj usting screw (located downstream of the pilot solenoid valve) clockwise to decrease or counter -clockwise to increase until a 1" (25mm) flame is obtained.
7. Re-install control box cover removed in step 4.
6
422-06TE
CLEVELAND SKILLETS
GAS TILTING OPEN BASE AND MODULAR SKILLETS
General Specifications:
• Leg or modular base
• Pull 40 gallon capacity rating to bottom of pouring lip
• Power tilt
• Stainless steel clad 5/8" cooking surface guaranteed against warping
• Stainless steel coved cornered pan with both gallon and
liter markings
• Space saving design - no clearance required at rear or
sides (optional faucet and console requires 4" on one side)
• All stainless steel construction for durability and easy
cleaning
• Adjustable, thermostat controls temperature from 100°F
to 425°F
• High efficiency heating system with even heat
distribution
• Fast heat -up and recovery time - preheats in 15
minutes, full capacity from cold to boiling in 60 minutes
• Spring assist cover with adjustable vent and full width
handle
• On/off switch, thermostat knob and pilots recessed to
avoid breakage
• Four stainless steel, level-adjustable feet, rear
flanged for bolting
• A.G.A., CGA, UL, CSA and NSF approved
• Serviceable from the front
• Three pilot lights, green-power on, amber-
temperature cycling, red-flash to indicate heal conditions
Options and Accessories:
Hydraulic hand tilt with quick lowering feature (HTS) Console mounted H/C water faucet (CMFS)
Double or single pantry skillet filler with 60" long
hose (SKF-S or DKF-S)
Hot and cold pre-rinse spray head with hose (PRS -S) Gas types other than natural Voltage and wiring other than standard Food strainer for pouring spout
MODELS:
_ SGL-30-T _ SGM-30-T _ SGL-40-T _ SGM-40-T
MODELS AVAILABLE
Model No. Description
SGL-30-T 30 gallons /115 liters, Gas, Tilting, Open
Base
SGL-40-T 40 gallons / 150 liters, Gas, Tilting, Open
Base
SGM -30-T 30 gallons / 115 liters, Gas, Tilting,
Modular Cabinet Base
SGM -40-T 40 gallons / 150 liters, Gas, Tilting,
Modular Cabinet Base
Pan carrier (PCS) Poaching Pans (PP) Vegetable steamers (VS) Wall mounting (WMS) In-wall carrier (IWCS)
2" butterfly valve c/w fittings to adapt to metering
filling stations (BVS-2)
Electronic spark ignition (ESS)
CLEVELAND RANGE, INC.
1333 East 179th St., Cleveland, Ohio 44110 Telex: 98-0546 -Facsimile: 216-481-3782
7