Cleveland SGL-30-T1 User Manual

Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
BRAISING PANS / TILTING SKILLETS
PowerPanSERIES
GAS, 35" RIM HEIGHT, 30 & 40 GALLON (110 & 150 LITER)
Cleveland Standard Features
II
A
vailable in 30 & 40 gallon (115 & 150 liter) open frame
design models. Full capacity to bottom of pouring lip.
II
Exclusive Ultra Efficient Power Burner (Forced-Air) Gas Combustion System with Automatic Ignition.
II
Exclusive Dual Power Settings: 90,000 and 125,000 Btu for 30 gallons, 160,000 Btu and 200,000 Btu for 40 gallons provides superior heat-up and recovery.
II
Open base design for easy cleaning and maintenance.
II
5/8" Stainless Steel Bead Blasted cooking surface prevents warping and keeps food from sticking.
II
Durable 12 gauge, 304 Stainless Steel pan construction.
5
/8˝ (16mm) mild steel clad bottom plus a 1/16˝ (1.6mm)
Stainless Steel plate for even temperature distribution.
II
Low 35" rim height for easy operation and cleaning.
II
Splash Proof Controls and construction.
II
Supplied with Cord & Plug for 115-volt controls.
II
Easy-to-turn manual hand tilt with enclosed permantly lubricated gearbox. Optional power tilt with manual override available.
II
Gallon/Liter Markings and Vented Spring Assist Cover standard.
II
Available with Optional 2" Tangent Draw-Off Valve.
II
10° Cooking Feature. Tilt unit up to 10° without the power being turned off.
II
Adjustable, Electronic Thermostat accurately controls temperature from 100° to 450° F.
II
Electronic "Spark Ignition System Standard".
II
Spring-Assist Cover with full width handle and vent.
II
Typical approvals include AGA, CSA, CE and NSF.
Options & Accessories
MODELS: SGL-30-T1
SGL-40-T1
Shown with optional 2" Tangent Draw Off Valve
Short Form Specifications
Shall be CLEVELAND, Tilting Skillet Model Number SGL-___-T1, gas (type____ ) holding no less than Dual Power Setting, Normal and High Power Cooking Controls, Power Burner (Forced-Air) Gas Combustion System, Automatic Ignition, Splash­Proof Construction, Spring Assist Cover with Vent, Gallon/Liter Markings, 5/8" Stainless Steel Clad Cooking Surface with Bead Blasted Finish, to use Manual Hand Tilt with Enclosed Permantly Lubricated Gearbox Adjustable Feet with Rear Flanged and Front Bullet Style.
_____ gallons ( _____ liters)
; Complete with
Easy
,
Ë Power Tilt with Manual Override (PT2)
Ë 2" (50 mm) Tangent Draw-Off Valve (TD2SK), left side only
Ë Double or Single Pantry Faucet (SPS14, DPS14),
includes Faucet Mounting Bracket
Ë Faucet Bracket (FBKT1)
Ë Pan Carriers (PCS), not available on 30 gallon
models with a Tangent Draw-Off Valve
Ë Vegetable Steamer Baskets (VS)
Ë Hot & Cold Water Pre-Rinse Spray Head with Hose (PRS-S)
Ë Poaching Pans (PP)
Ë Voltage Option:
• VOSK3, 440/480 Volt, 60 Hz, 3 Phase
• VOSK4, 220/240 Volt, 50 Hz, 1 Phase - for export
Ë Protective Control Cover (CP-PCB-T1)
Ë Casters, 2 swivel, 2 locking (CST1)
SECT. XII PAGE 11
0609
DPK (OPTION)
H C
DPK (OPTION)
39"
991mm
35"
889mm
(RIM
HEIGHT)
12 5/8"
321mm
71"
1804mm
75°
28 3/4"
7
31mm
(PAN
S
URFACE)
15 5/8"
397mm
2"
A
B
(PAN SURFACE)
4
1"
1042mm
25 15/16"
(659mm)
E
(
MINIMUM)
3 7/8" (99mm)
C
5 1/4"
(134mm)
(FAUCET O
PEN)
33"
(839mm)
5
"
(127mm)
(MANUAL
TILT HANDLE)
D
1
20V
ONLY
RECOMMENDED FLOOR
SLOPE 1" (26mm) IN 4' (1220mm)
FLOOR DRAIN
PIPE DRAIN RECOMMENDED MINIMUM VALVE SIZE PLUS 1" (26mm)
4" (102mm) MINIMUM
6" (153mm) RECOMMENDED
ZERO CLERANCE FOR NON-COMBUSTIBLE WALL, 3 1/2" (89mm) MINIMUM CLEARANCE FOR COMBUSTIBLE WALL
W
ALL
LEG LOCATION &
SUGGESTED FLOOR DRAIN DETAIL
WALL
MODEL
S
GL-30-T1
SGL-40-T1
A
3
7 7/8"
(963mm)
4
9 7/8"
(
1267mm)
ELECTRICAL S
UPPLY
TYPE: NAT or LP
W
ATER COLUMN: 3.5 (NAT), 10 (LP)
BTU PER CU. FT.: 1025 (NAT), 2500 (LP)
S
UPPLY PRESSURE:
5
" W.C. MIN (NAT), 11" W.C. MIN (LP)
BTU RATINGS:
SGL-30-T : 125,000 per hour
S
GL-40-T : 200,000 per hour
RIGHT:
4
" (102mm) (manual tilt)
1” (26mm) (power tilt)
L
EFT: 0"
R
EAR:
0 (non-combustible wall)
3.5" (89mm)
(
combustible wall)
SGL-30-T1
5
20 LBS.
235 KG.
S
GL-40-T1
560 LBS.
255 KG.
APPROX. S
HIPPING
W
EIGHTS
GAS SUPP LY (
PIPING 3/4" NPT)
CLEARANCE
SPECIFICATIONS
DIMENSIONS CAPACITIES
B
2
4 1/2"
(623mm)
3
6 1/2"
(
928mm)
F
1
8 1/4"
(464mm)
2
4 1/4"
(
616mm)
G
5
3/4"
(146mm)
5
3/4"
(
146mm)
H
8
"
(204mm)
8
"
(
204mm)
C
3
1 3/4"
(807mm)
4
3 3/4"
(
1112mm)
D
1
2"
(305mm)
1
8"
(
458mm)
E
(
combustible wall)
3
1/2"
(89mm)
3
1/2"
(
89mm)
E
b
ustible wall)
2
2
In 4 oz. servings. Other sizes may be calculated.
30 gallons / 115 Liters.............960
40 gallons / 150 Liters...........1280
9 1/2" (241mm)
(PAN DEPTH)
H C
(
non-com-
VOLTS: 120
PHASE: 1
A
MPS: 1.4
FREQ: 60 HZ
220/240
1
1
.5
50 HZ
F
LOOR
D
RAIN
G
RATE
12" x 20" (305mm x
508mm)
F
OR OPTIONAL 2" TD VALVE
I
NCREASE FLOOR
D
RAIN GRATE SIZE TO
24" x 20" (610mm x 508mm)
7/16"Ø, 3 HOLES
ON 3 1/8" (80mm) B.C.D.
FLANGED FOOT DETAIL
(REAR LEGS ONLY)
120°120°
4 7/8" (124mm)
9/16" (15mm)
1" (26mm)
(MAXIMUM
ADJUSTMENT
2" (51mm)
2 1/4"
(57mm)
NOTE: OPTIONAL 2" TD VALVE SHOWN IN GRAY
3
8"
966mm
TD 2 OUTLET
42 3/4"
1086mm
TD 2
H
23"
585mm
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., NSF, CGA, CSA, ETL and others.
(NOT TO SCALE)
SECT. XII PAGE 12
0609
Litho in U.S.A.
Loading...