Line Length Weight
Model ft. m. lbs. kgs.
RC-22 20 6.2 19 9
RC-32 30 9.2 27 12
RC-52 50 15.2 38 17
Standard Interconnecting Tubing
Manitowoc QuietQube®Q-Dual Remote Series
REMOTE AIR-COOLED ICE MACHINE
WITH CVD 1875 OR CVD 2075 CONDENSING UNIT
CVD REMOTE CONDENSING UNIT
EITHER CVD 1875 OR CVD 2075
THE RIGHT CLIMATE FOR LEADERSHIP
Manitowoc Ice, Inc.
2110 South 26th Street, P.O. Box 1720 • Manitowoc, WI 54221-1720, USA
Ph: 920-682-0161 • Fax: 920-683-7589
www.manitowocice.com
©2002 Manitowoc 9724C - 12/02
Continuing product improvement may necessitate change of specifications without notice.
Consult your local Manitowoc Representative:
Installation Information and Dimensions:
Maximum Line Length—100’ (3,000 cm).*
Maximum Vertical Rise*—35’(1,050 cm) above ice machine.
Maximum Vertical Drop—15’(450 cm) below ice machine.
*A rise over 20' (600 cm) requires S-Trap Kit K-00164 -
ordered separately.
208-230/60/1 standard. 208-230/60/3
and 230/50/1 also available. 50 Hz
version of this model meets the
international standard, IEC335-1,
requirements for "tropical rating,"
the most severe duty rating an ice
machine can obtain, (consult
factory). HACR-type circuit breakers
can be used in place of fuses.
Note: QuietQube ice machine is
115/60/1 and wired independent
of CVD condensing unit.
Min. circuit ampacity:
CVD 1875 CVD 2075
24.3
1ph
27.1
1ph
16.1
3ph
19.9
3ph
Max. fuse size:
CVD 1875 CVD 2075
40 amps
1ph
50 amps
1ph
30 amps
3ph
40 amps
3ph
HACR-type circuit breakers can be
used in place of fuses.
Operating Limits:
•Ambient Temperature Range:
-20˚ to 130˚F (-29˚ to 54˚C)
Ice Machine Electric
Condensing Unit Electric
Specifications
115/60/1 standard.
(230/50/1 also available,
consult factory.)
Total amps: 1.1
Max. fuse size: 15 amps
HACR-type circuit
breakers can be used
in place of fuses.
BTU Per Hour:
CVD 1875: 28,000 (average) 42,000 (peak)
CVD 2075: 39,000 (average) 53,000 (peak)
Compressor:
CVD 1875: Nominal rating: 3.5 HP
CVD 2075: Nominal rating: 5.0 HP
Operating Limits:
•Ambient Temperature Range:
35˚ to 110˚F (1.6˚ to 43.4˚C)
•Water T emperatur e Range:
33˚ to 90˚F (0.6˚ to 32.2˚C)
•Water Pressure Ice Maker Water In:
Min. 20 psi (137.9 kPA)
Max. 80 psi (551.1 kPA)
Ice machine for use with ice storage bin or ice dispenser and CVD condensing unit all ordered separately. *kWh per
100 lbs. is total power of ice machine and condensing unit. Ice machine is 1 ph only.Condensing unit is 1 ph or 3 ph.
✝Production for Dice and Half Dice cubes. Regular cube is 7%
less than chart and kWh/100 lbs. increases 7%.
24-HOUR PRODUCTION †
REMOTE AIR-COOLED UNIT
air
water temp
temp CVD 1875 CVD 2075
˚F 50˚ 70˚ 90˚ 50˚ 70˚ 90˚
˚C 10˚ 21˚ 32˚ 10˚ 21˚ 32˚
-20˚ to 70˚ 1,820 1,670 1,560 2,000 1,800 1,700
-29˚ to 21˚ 826 758 708 908 817 772
90˚ 1,650 1,530 1,420 1,930 1,750 1,650
32˚ 749 695 645 876 795 749
100˚ 1,530 1,410 1,300 1,810 1,650 1,550
38˚ 695 640 590 822 749 704
Ice production 24 hours Power kWh/100 lbs*
CVD 1875 CVD 2075 CVD 1875 CVD 2075
Model Cube size lbs. kgs. lbs . kgs. 1 ph 3 ph 1 ph 3 ph
QRDUAL0C regular 1,425 647 1,625 738 6.5 6.1 7.3 7.1
QDDUAL2C dice 1,530 695 1,750 795 6.1 5.7 6.8 6.6
QYDUAL4C half-dice 1,530 695 1,750 795 6.1 5.7 6.8 6.6
Water usage/100 lbs./45.4 kgs. of Ice
Potable Water: CVD 1875: 18 gallons, 68.14 liters. CVD 2075: 22.8 gallons, 86.30 liters.
Certified in Accordance with ARI Automatic Commercial Ice-Cube Machines
(Batch-Type) Certification Program, which is based on ARI Standard 810