PRESSURE STEAMERS
PRESSURE STEAMERS
2 OR 3 COMPARTMENTS, CABINET MOUNTED ELECTRIC STEAM GENERATOR 24, 36 OR 48 KW, 36” WIDE CABINET BASE
Cleveland Standard Features
I
I
5 psi Operating Pressure in cooking compartments
II
Mechanical interlock prevents unlatching door while compartment is pressurized
II
Timers, one per compartment, are mechanical style with audible signal
I
I
Thermostatic Trap vents cooking compartment automatically
II
Steam Inlet Valves and Exhaust Valves interlocked for synchronous action
II
8 psi Compartment Safety Valve
II
Capacity per compartment for eight, 12” x 20” x 2 1/2” deep Cafeteria Pans, or four, 18” x 26” Bun Pans
II
Heavy Duty, free floating, cast aluminum compartment doors
II
Compartment Door Hinges have adjustable hinge pins and self-lubricating bushings
II
Door Gasket replaceable without tools
II
Pressure Gauge for compartment operating pressure
II
Compartment Slide Racks are removable without tools, for easy cleaning
II
Type 430 Stainless Steel: external enclosure, Table Top and eight gage plate cooking compartments
II
Modular Cabinet Base with Hinged Doors
II
High efficiency Electric Steam Generator with Automatic Water Fill on start-up
II
Automatic Water Level Control System with Low Water Power Cut-off Circuit
II
Steam Generator equipped with High-limit Pressure Safety Switch and Safety Valve
II
Automatic Steam Generator (boiler) Blowdown allows intermittent control, complete with additional Manual Drain Valve
II
Steam Generator Pressure Gauge
II
6” Stainless Steel Legs with level adjustment and flanged feet
II
Single Cold Water Connection (no hot water required)
Ë Secondary Low Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
II
Standard Voltage 208-240 volts, 60 hz, single phase, three wire
II
All Major Components are serviceable from the front of unit
Options & Accessories
MODELS:
2 Compartments 3 Compartments
PEM-24-2 PEM-24-3PEM-36-2 PEM-36-3PEM-48-2 PEM-48-3
Short Form Specifications
Shall be _____ Compartments, CLEVELAND, Pressure Steamer, Model PEM- _____ - _____ , Electric Steam Generator, _____ kw, _____ volts, _____ ph, three wire. Each Cooking Compartment equipped with: 60 Minute Timer; Heavy-duty, free floating Door with Safety Interlock; and synchronous operating Steam Inlet and Exhaust/Drain Valves. Solid State Controls operate Water Level and Steam Generator (boiler) Safety Functions. Automatic Steam Generator (boiler) Blowdown with additional Manual Drain Valve.
Ë Kettle Interconnecting Kit (IMK)
Ë Stainless Steel base Frame (FSS)
Ë Stainless Steel gas flue cover, insulated (SSF)
Ë Special compartment Slide Racks
Ë 12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep
Ë Intermediate Pull-Out Shelf (POS)
Ë Spray Head with flexible Hose (SH)
Ë Voltages, other than standard
Ë
Water Filters
Ë Correctional Packages
Ë Automatic Steam Inlet and Exhaust Operation (AT-2): includes
60 minute Automatic Timers and Manual Bypass
Ë 15 psi for Kettle Operation, includes Power Take-Off (PTO)
SECT. VI PAGE 1
0609
Each compartment has capacity for:
C
Eight, 12˝ x 20˝ x 2
1
2˝ Cafeteria Pans or Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or
our, 18˝ x 26˝ Bun Pans
F Many regional, state and local codes exist and it is
the responsibility of the owner and installer to com­ply with those codes.
Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included among those approval agencies are: UL, NSF, ASME/N.Bd., CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
ELECTRIC
KW Volts Watts Ph Amps Wire
24 208 21,500 1 103.4 2
220 24,000 1 109.1 2
240 24,000 1 100.0 2
440 20,200 1 45.9 2
480 24,000 1 50.0 2
208 21,500 3 59.7 3
220 24,000 3 63.1 3
240 24,000 3 57.8 3
440 20,200 3 26.5 3
480 24,000 3 28.9 3
600 24,000 3 23.1 3
360 21,500 3 34.5 4
380 24,000 3 36.5 4
415 24,000 3 33.4 4
Cleveland Range reserves right of design improvement or modification, as warranted.
KW Volts Watts Ph Amps Wire 36 208 32,200 3 89.5 3
220 36,000 3 94.6 3 240 36,000 3 86.7 3 440 30,200 3 39.7 3 480 36,000 3 43.4 3 600 36,000 3 34.7 3 360 32,200 3 51.7 4 380 36,000 3 54.8 4 415 36,000 3 50.1 4
48 208 42,900 3 119.2 3
220 48,000 3 126.1 3 240 48,000 3 115.6 3 440 40,300 3 52.9 3 480 48,000 3 57.8 3 600 48,000 3 46.2 3 360 42,900 3 68.9 4 380 48,000 3 73.0 4 415 48,000 3 66.9 4
WATER DRAINAGE CLEARANCE
1/4˝ NPT Cold Water Inlet
35 psi minimum
60 psi maximum
The Floor Drain must be located outside the confines of the equipment base.
1 1/2˝ I.P.S. common drain. Do not connect other units to this drain. Do not use PVC pipe for drain.
D
Right - 3”, Left - 3”, Rear - 3” (12” on control side if adjoining wall or equipment is over 30” high for service access)
Contact factory for variances to clearances.
(NOT TO SCALE)
SECT. VI PAGE 2
0609
Litho in U.S.A.