Cleveland PDL-4 User Manual

Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
PRESSURE STEAMERS
PRESSURE STEAMERS
2 OR 3 OR 4 COMPARTMENTS DIRECT STEAM, OPEN STAND PEDESTAL BASE OR WALL MOUNTED
Cleveland Standard Features
5 psi Operating Pressure in cooking compartments
II
II
echanical interlock prevents unlatching door while compartment
M is pressurized
I
I
Timers, one per compartment, are mechanical style with audible signal
II
Thermostatic Trap vents cooking compartment automatically
II
Steam Inlet Valves and Exhaust Valves interlocked for synchronous action
II
8 psi Compartment Safety Valve
II
Capacity per compartment for eight, 12” x 20” x 2 1/2” deep Cafeteria Pans, or four, 18” x 26” Bun Pans
II
Heavy Duty, free floating, cast aluminum compartment doors
II
Compartment Door Hinges have adjustable hinge pins and self-lubricating bushings
II
Door Gasket replaceable without tools
II
Pressure Gauge for compartment Operating Pressure
II
Compartment Slide Racks are removable without tools, for easy cleaning
II
Type 430 Stainless Steel: external enclosure, Table Top and eight gauge plate cooking compartments
II
Moisture Separator for incoming steam
II
Pressure Reducing Valve for 12 to 50 psi steam supply pressure
II
6” Adjustable Legs with flanged feet
Compartments 3 Compartments 4 Compartments
MODELS:
2
PDL-2 PDL-3 PDL-4PDW-2 PDW-3 PDW-4
Short Form Specifications
Shall be _____ Compartments, CLEVELAND, Pressure Steamer, Model PD- _____ - _____ , for Direct Steam operation,; _____ volts, sin­gle phase. Each Cooking Compartment equipped with: 60 Minute Timer; Pressure Safety Valve; Heavy-duty, free floating Door with Safety Interlock; and synchronous operating Steam Inlet and Exhaust/Drain Valves. Compartments are mounted to a Low Cabinet type base or Wall Mounted. Includes a Pressure Reducing Valve and Moisture Separator.
Options & Accessories
Ë Automatic Steam Inlet and Exhaust Operation (AT-2):
includes 60 minute Automatic Timers and Manual Bypass
Ë Second Pressure Reducing Valve for 50 to 120 psi supply
pressure (PRV)
Ë Special Compartment Slide Racks Ë 12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep Ë Intermediate Pull-Out Shelf (POS) Ë In-Wall Carrier, for wall mounted units only (IWC-PDW)
L Clean, non toxic, uncontaminated steam is required for all
“Direct Steam” steamers
SECT. VI PAGE 9
0609
Each compartment has capacity for:
Eight, 12˝ x 20˝ x 2
1
2˝ Cafeteria Pans or Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or Four, 18˝ x 26˝ Bun Pans
Many regional, state and local codes exist and it is
the responsibility of the owner and installer to com­ply with those codes.
Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included among those approval agencies are: UL, ULC, NSF, and CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
WALL MOUNTED
1” IPS common drain.
Do not connect other units to this drain.
Do not use PVC pipe for drain.
Cleveland Range reserves right of design improvement or modification, as warranted.
LOW-CABINET TYPE
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoin­ing wall or equipment is over 30” high for service access)
Contact factory for variances to clearances.
(NOT TO SCALE)
SECT. VI PAGE 10
0609
Litho in U.S.A.