UNIT A
UNIT B
NOTE: Overall height of unit does not change for units with casters.
6.00"
30.19"
5.98"
28.46"
4.41"
40.73"
70.64"
4
7.82"
47.82"
R
C
C
S
W1 W2
D
RC
CS
W1 W2
D
G
G
G
COMBI OVEN-STEAMER Stacking Kits for Gas Table Type Models (OGB 6.10 on OGB 6.20 or OGS 6.10 on OGS 6.20)
Model # Description
CSTKG610620 for mounting one 6.10 model on top of one 6.20 model
CSTKG610620CA for mounting one 6.10 model on top of one 6.20 model (with casters)
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
Gas Connection: 3/4" NPT Gas Type: Natural Gas (Propane optional) Gas Flow Pressure: Natural Gas - Min. 5.5" WC / Max. 14" WC
BOILER MODELS
Total Connected Load: 45.400 BTU 75,700 BTU Steam Generator: 45.400 BTU 68,200 BTU Hot Air: 45.400 BTU 75,700 BTU
BOILERLESS MODELS
Total Connected Load: 45.400 BTU 75,700 BTU Hot Air: 45.400 BTU 75,700 BTU
Rear - 2", Left Side - 4", Right Side - 2 1/2"
120 volt, 60 Hz, single phase,
Propane Gas - Min. 11" WC / Max. 14" WC
UNIT A - OGB 6.10 UNIT B - OGB 6.20
UNIT A - OGS 6.10 UNIT B - OGS 6.20
UNIT A -
11.7 amps
UNIT B -
11.7 amps
Water Connections: Cold Water (drinking water quality)
Flow Pressure: 35 - 60 PSI Water Inlets:
Treated Water for Steam Generator Untreated Water for Condenser
NOTE: The owner / operator / purchaser must ensure that the Water Quality Requirements are met. Not meeting the water quality requirements will void the original equipment warranty.
TDS . . . . . . . . . . . . < 60 ppm pH Factor . . . . . 7.0 – 8.5
Total Alkalinity . . . . < 20 ppm Free Chlorine. . . < 0.1 ppm
Silica . . . . . . . . . . . < 13 ppm Conductivity . . . min. 20 µS/cm (50 kOhms)
Chloride . . . . . . . . < 25 ppm
3/4" GHT-F (Female Garden Hose Connection)
Drain Connection: 2” I.D. No Hub Elbow Provided
Venting: Exhaust Hood required
Connection for Cleaning Solution (Available as an option)
Connection for Rinse Cycle (Available as an option)
Note: For additional connection details, see spec sheet
for each individual combi model to be stacked.
SECT. IIB PAGE 5E
0911