Cleveland
™
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
CSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
UNIT A
UNIT B
NOTE: Overall height of unit does not change for units with casters.
R
C
C
S
W1 W2
D
G
RC
CS
W1 W2
D
G
4.38"
38.08"
39.21"
L
EFT SIDE VIEW
UNIT A
UNIT B
36.70"
1.58"
28.43
5
.00"
1
.82"
67.8 5 "
28.43
6.00"
78.00” (MIN. HOOD REQUIREMENT)
2.52"
COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)
Model # Description
CSTKG610 for mounting two 6.10 models
STKG610CA for mounting two 6.10 models (with casters)
C
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located
next to the unit.
• Allow for sufficient clearance on left side for service access (contact the
factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
Gas Connection: 3/4" NPT
Gas Type: Natural Gas (Propane optional)
Gas Flow Pressure: Natural Gas - Min. 5.5" WC / Max. 14" WC
BOILER MODELS
Total Connected Load: 45.400 BTU 45.400 BTU
Steam Generator: 45.400 BTU 45.400 BTU
Hot Air: 45.400 BTU 45.400 BTU
BOILERLESS MODELS
Total Connected Load: 45.400 BTU 45.400 BTU
Hot Air: 45.400 BTU 45.400 BTU
Rear - 2", Left Side - 4", Right Side - 2 1/2"
120 volt, 60 Hz, single phase,
UNIT A UNIT B -
11.7 amps
11.7 amps
Propane Gas - Min. 11" WC / Max. 14" WC
UNIT A - OGB 6.10 UNIT B - OGB 6.10
UNIT A - OGS 6.10 UNIT B - OGS 6.10
Water Connections: Cold Water (drinking water quality)
Flow Pressure: 35 - 60 PSI
Water Inlets:
Treated Water for Steam Generator Untreated Water for Condenser
NOTE: The owner / operator / purchaser must ensure that the Water Quality
Requirements are met. Not meeting the water quality requirements will void the
original equipment warranty.
Water Quality Requirements:
TDS . . . . . . . . . . . . < 60 ppm pH Factor . . . . . 7.0 – 8.5
Total Alkalinity . . . . < 20 ppm Free Chlorine. . . < 0.1 ppm
Silica . . . . . . . . . . . < 13 ppm Conductivity . . . min. 20 µS/cm (50 kOhms)
Chloride . . . . . . . . < 25 ppm
3/4" GHT-F (Female Garden Hose Connection)
Drain Connection: 2” I.D. No Hub Elbow Provided
Venting: Exhaust Hood required
Connection for Cleaning Solution (Available as an option)
Connection for Rinse Cycle (Available as an option)
Note: For additional connection details, see spec sheet
for each individual combi model to be stacked.
SECT. IIB PAGE 5A
0911