Cleveland CSTKG1010CA User Manual

Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
UNIT A
UNIT B
RC
CS
W1 W2
D
G
RC
C
S
W1 W2
D
G
4.38"
48.54”
39.21"
NOTE: Overall height of unit does not change for units with casters.
U
NIT A
UNIT B
L
EFT SIDE VIEW
78.41"
36.70"
1.58"
1.82"
28.43
5.00"
38.98"
6.00"
80.00” (MIN. HOOD REQUIREMENT)
2.52"
G
D
RC
CS
W1
W2
COMBI OVEN-STEAMER Stacking Kits for Gas Table Type Models (OGB 6.10 on OGB 10.10 or OGS 6.10 on OGS 10.10)
Model # Description
CSTKG1010 for mounting one 6.10 model on top of one 10.10 model
CSTKG1010CA for mounting one 6.10 model on top of one 10.10 model (with casters)
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
Gas Connection: 3/4" NPT Gas Type: Natural Gas (Propane optional) Gas Flow Pressure: Natural Gas - Min. 5.5" WC / Max. 14" WC
BOILER MODELS
Total Connected Load: 45.400 BTU 75,700 BTU Steam Generator: 45.400 BTU 68,200 BTU Hot Air: 45.400 BTU 75,700 BTU
BOILERLESS MODELS
Total Connected Load: 45.400 BTU 75,700 BTU Hot Air: 45.400 BTU 75,700 BTU
Rear - 2", Left Side - 4", Right Side - 2 1/2"
120 volt, 60 Hz, single phase,
UNIT A ­UNIT B -
11.7 amps
11.7 amps
Propane Gas - Min. 11" WC / Max. 14" WC
UNIT A - OGB 6.10 UNIT B - OGB 10.10
UNIT A - OGS 6.10 UNIT B - OGS 10.10
3/4" GHT-F (Female Garden Hose Connection)
Water Connections: Cold Water (drinking water quality)
Flow Pressure: 35 - 60 PSI Water Inlets:
Treated Water for Steam Generator Untreated Water for Condenser
NOTE: The owner / operator / purchaser must ensure that the Water Quality Requirements are met. Not meeting the water quality requirements will void the original equipment warranty.
Water Quality Requirements:
TDS . . . . . . . . . . . . < 60 ppm pH Factor . . . . . 7.0 – 8.5
Total Alkalinity . . . . < 20 ppm Free Chlorine. . . < 0.1 ppm
Silica . . . . . . . . . . . < 13 ppm Conductivity . . . min. 20 µS/cm (50 kOhms)
Chloride . . . . . . . . < 25 ppm
Drain Connection: 2” I.D. No Hub Elbow Provided
Venting: Exhaust Hood required
Connection for Cleaning Solution (Available as an option)
Connection for Rinse Cycle (Available as an option)
SECT. IIB PAGE 5B
0911
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
Loading...