Cleveland CSTKE610 User Manual

D
RC
CS
W1
W2
Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
CSI Section _________________ ___________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
37.83"
L
EFT SIDE VIEW
36.70"
1.58"
1.82"
2.52"
R
C
CS
W1 W2
D
RC
CS
W1 W2
D
NOTE: Overall height of unit does not change for units with casters.
4.38"
38.08"
28.43
5.00"
67.8 5 "
28.43
6.00"
78.00” (MIN. HOOD REQUIREMENT)
UNIT A
UNIT B
UNIT A
UNIT B
COMBI OVEN-STEAMER Stacking Kits for Electric Table Type Models (OEB 6.10 on OEB 6.10 or OES 6.10 on OES 6.10)
Model # Description
CSTKE610 for mounting two 6.10 models
STKE610CA for mounting two 6.10 models (with casters)
C
UTILITIES (Utility connection shown below are listed per unit)
Rear - 2", Left Side - 4", Right Side - 2 1/2"
Do not connect to a G.F.I. outlet.
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
Required Clearances:
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
BOILER UNIT A - OEB 6.10 UNIT B - OEB 6.10 MODELS
Total Connected Load: 9.9 KW 12.8 KW 11 KW 13.1 KW 9.9 KW 12.8 KW 11 KW 13.1 KW Hot Air: 8.6 KW 11.4 KW 9.1 KW 10.2 KW 8.6 KW 11.4 KW 9.1 KW 10.2 KW Steam Generator: 7.7 KW 10.2 KW 8.6 KW 10.2 KW 7.7 KW 10.2 KW 8.6 KW 10.2 KW Amps per Phase: 27.3 30.8 15.2 16.3 27.3 30.8 15.2 16.3
BOILERLESS UNIT A - OES 6.10 UNIT B - OES 6.10 MODELS
Total Connected Load: 9.9 KW 12.8 KW 11 KW 13.1 KW 9.9 KW 12.8 KW 11 KW 13.1 KW Hot Air: 8.6 KW 11.4 KW 9.1 KW 10.2 KW 8.6 KW 11.4 KW 9.1 KW 10.2 KW Amps per Phase: 27.3 30.8 15.2 16.3 27.3 30.8 15.2 16.3
Water Connections: Cold Water (drinking water quality)
Flow Pressure: 35 - 60 PSI Water Inlets:
Treated Water for Steam Generator Untreated Water for Condenser
NOTE: The owner / operator / purchaser must ensure that the Water Quality Requirements are met. Not meeting the water quality requirements will void the original equipment warranty.
TDS . . . . . . . . . . . . < 60 ppm pH Factor . . . . . 7.0 – 8.5
Total Alkalinity . . . . < 20 ppm Free Chlorine. . . < 0.1 ppm
Silica . . . . . . . . . . . < 13 ppm Conductivity . . . min. 20 µS/cm (50 kOhms)
Chloride . . . . . . . . < 25 ppm
3/4" GHT-F (Female Garden Hose Connection)
Drain Connection: 2” I.D. No Hub Elbow Provided
Venting: Exhaust Hood required
Connection for Cleaning Solution (Available as an option)
Connection for Rinse Cycle (Available as an option)
Note: For additional connection details, see spec
sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5G
0911