80.09"
47.92"
2
.52"
1.58"
1
.82"
30.12"
5.00"
38.98"
6.00"
81.00” (MIN. HOOD REQUIREMENT)
RC
CS
W1 W2
D
RC
CS
W1 W2
D
4.38"
48.32"
46.34"
NOTE: Overall height of unit does not change for units with casters.
UNIT A UNIT A
UNIT B
UNIT B
LEFT SIDE VIEW
FRONT VIEW
COMBI OVEN-STEAMER
Stacking Kits for Electric Table Type Models
(OEB 6.20 on OEB 10.20 or OES 6.20 on OES 10.20)
Model # Description
CSTKE1020 for mounting one 6.20 model on top of one 10.20 model
CSTKE1020CA for mounting one 6.20 model on top of one 10.20 model (with casters)
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to
the unit.
• Allow for sufficient clearance on left side for service access (contact the factory
service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
BOILER UNIT A - OEB 6.20 UNIT B - OEB 10.20
MODELS
Total Connected Load: 16.4 KW 21.6 KW 18.5 KW 22 KW 26.3 KW 34.9 KW 29.4 KW 34.9 KW
Hot Air: 14.7 KW 19.6 KW 16.5 KW 19.6 KW 25.8 KW 34.3 KW 28.8 KW 34.3 KW
Steam Generator: 12.8 KW 17.1 KW 14.3 KW 17.1 KW 20.5 KW 27.3 KW 22.9 KW 27.3 KW
Amps per Phase: 45.5 51.8 24.2 26.4 77.8 88.8 41.4 44.9
BOILERLESS UNIT A - OES 6.20 UNIT B - OES 10.20
MODELS
Total Connected Load: 16.4 KW 21.6 KW 18.5 KW 22 KW 26.3 KW 34.9 KW 29.4 KW 34.9 KW
Hot Air: 14.7 KW 19.6 KW 16.5 KW 19.6 KW 25.8 KW 34.3 KW 28.8 KW 34.3 KW
Amps per Phase: 45.5 51.8 24.2 26.4 77.8 88.8 41.4 44.9
Do not connect to a G.F.I. outlet.
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
Water Connections: Cold Water (drinking water quality)
Flow Pressure: 35 - 60 PSI
Water Inlets:
Treated Water for Steam Generator Untreated Water for Condenser
NOTE: The owner / operator / purchaser must ensure that the Water Quality
Requirements are met. Not meeting the water quality requirements will void the
original equipment warranty.
Water Quality Requirements:
TDS . . . . . . . . . . . . < 60 ppm pH Factor . . . . . 7.0 – 8.5
Total Alkalinity . . . . < 20 ppm Free Chlorine. . . < 0.1 ppm
Silica . . . . . . . . . . . < 13 ppm Conductivity . . . min. 20 µS/cm (50 kOhms)
Chloride . . . . . . . . < 25 ppm
3/4" GHT-F (Female Garden Hose Connection)
Drain Connection: 2” I.D. No Hub Elbow Provided
Venting: Exhaust Hood required
Connection for Cleaning Solution (Available as an option)
Connection for Rinse Cycle (Available as an option)
Note: For additional connection details, see spec sheet
for each individual combi model to be stacked.
SECT. IIB PAGE 5K