Cleveland OEB-620, CSTK-1020, CSTK-1020CA Specifications

Page 1
Cleveland
P
roject ________________________________
Item __________________________________
Quantity _______________________________
F
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
80.09"
47.92"
2
.52"
1.58"
1
.82"
30.12"
5.00"
38.98"
6.00"
81.00” (MIN. HOOD REQUIREMENT)
RC
CS
W1 W2
D
RC
CS
W1 W2
D
4.38"
48.32"
46.34"
NOTE: Overall height of unit does not change for units with casters.
UNIT A UNIT A
UNIT B
UNIT B
LEFT SIDE VIEW
FRONT VIEW
D
RC
CS
W1
W2
COMBI OVEN-STEAMER Stacking Kits for Electric Table Type Models (OEB 6.20 on OEB 10.20 or OES 6.20 on OES 10.20)
Model # Description
CSTK-1020 for mounting one 6.20 model on top of one 10.20 model
CSTK-1020CA for mounting one 6.20 model on top of one 10.20 model (with casters)
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
• Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
BOILER UNIT A - OEB-6.20 UNIT B - OEB-10.20 MODELS
Total Connected Load: 16.4 KW 21.6 KW 18.5 KW 22 KW 26.3 KW 34.9 KW 29.4 KW 34.9 KW Hot Air: 14.7 KW 19.6 KW 16.5 KW 19.6 KW 25.8 KW 34.3 KW 28.8 KW 34.3 KW Steam Generator: 12.8 KW 17.1 KW 14.3 KW 17.1 KW 20.5 KW 27.3 KW 22.9 KW 27.3 KW Amps per Phase: 45.5 51.8 24.2 26.4 77.8 88.8 41.4 44.9
BOILERLESS UNIT A - OES-6.20 UNIT B - OES-10.20 MODELS
Total Connected Load: 16.4 KW 21.6 KW 18.5 KW 22 KW 26.3 KW 34.9 KW 29.4 KW 34.9 KW Hot Air: 14.7 KW 19.6 KW 16.5 KW 19.6 KW 25.8 KW 34.3 KW 28.8 KW 34.3 KW Amps per Phase: 45.5 51.8 24.2 26.4 77.8 88.8 41.4 44.9
Do not connect to a G.F.I. outlet.
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
Water Connections: Cold Water (drinking water quality) Flow Pressure: 30 - 60 PSI Water Inlets: 3/4" GHT-F (Female Garden Hose
Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
Venting: Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*Available as an option
Note: For additional connection details,
see spec sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5K