MODULAR BASES
MODULAR CABINET BASE
ELECTRIC STEAM GENERATOR
24, 36 or 48 KW
24" (600MM) or 36" (900MM) WIDE BASE
Cleveland Standard Features
n Type 304 Stainless Steel exterior enclosure; TableTop with
#4 finish
n Hinged Cabinet Door
n 6" Stainless Steel Legs with le
n Solid State Steam Generator Water Level Controls
n Low Water Power Cut-off
n Pressure Limit Controls with 15 psi Safety Valve
n Major components serviceable from the front of the unit
n Steam Generator empties under pressure (blowdown)
automatically upon each Shut-Down. Automatic Water
Refill on Start-Up
n Separate "Start/Reset" illuminated switch controls, plus
Pressure Gauge
n Steam Generator Drain incorporates Water Cooling and
"Jet Rinsing"
n Steam Generator is complete with Access Hole/Cover Plate
and Sight Glass Gauge
n Secondary Low Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI.
MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA.WV., Buffalo, NY,
Wash. DC)
n Standard voltage is 208/220 volt, 60 Hz, 3 Phase,
3 Wire
n Single cold water Connection (no hot water required)
vel adjustment
MODELS: c 24-EM-24 c 36-EM-24
c 24-EM-36 c 36-EM-36
c 24-EM-48 c 36-EM-48
Short Form Specifications
Shall be CLEVELAND Model _____ -Em _____ KW Electric Steam Generator,
Modular Cabinet Base, type 304 Stainless Steel exterior enclosure, Table
Top and 6" Level Adjustable Legs. Console mounted Controls, Pressure
Gauge and Illuminated "Start/Reset" Control Switches. Solid State Water
Level Steam Generator Controls. Steam Generator drains under pressure
(blowdown) after each Shut-Down, Automatic Water Fill on Start-Up.15 psi
Safety Valve.
Options & Accessories
p Power Take-Off Kit (EPTO)
p V
oltages other than standard, including: 220/240, 440/480,
575 volt
p Single Phase oper
p 10" Adjustable Legs (LF10)
p Flanged Feet (FF)
p Stainless Steel Base F
ation (24 KW
ame (FSS)
r
only)
SECT. VII PAGE 1
0707

WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
u
se per day, and a Daily Blowdown, are as follows:
OTAL DISSOLVED SOLIDS less than 60 parts per million
T
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it
will be suitable for the generator.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA.
1 1/2” IPS common drain.
Do not connect other
units to this drain.
Do not use PVC pipe for
ain.
dr
Right - 3”, Left - 3”, Rear - 3”
on control side if adjoining
(12”
wall or equipment is over 30”
high f
or service access)
Contact factory for
ariances to c
v
learances.
(NOT TO SCALE)
.