Clements SUC89660, SUC89661 User Manual

User Manual
CLEMENTS
Duplex Adaptors
SUC89660 SUC89661
Manual No. SUC 89660 081
2
CLEMENTS
Safety
Thank you for purchasing this Clements Duplex Adaptor.
For your safety it is imperative that this unit only be operated by authorised personnel in accordance with the instructions as described in this manual. Operated in this way, the Duplex Adaptor will provide years of service.
Due to continual improvements in product design, the Duplex Adaptor may vary in detail from the descriptions in this manual. In the event of further questions please contact your local distributor or BMDi TUTA Healthcare direct.
User Manual Duplex Adaptor
Manual Number SUC 89660 081 Issue 10 Copyright © 2014 BMDi TUTA Healthcare Pty Ltd
The information in this manual was originated by, and is the exclusive property of BMDi TUTA Healthcare Pty Ltd. It is furnished for customer information only, and is not an authorisation or licence to make this product or to furnish this information to others.
BMDi TUTA Healthcare Pty Ltd Unit 4B, 128-130 Frances Street Lidcombe NSW 2141 Australia Phone: +61 2 9466 5300 Website: www.medaust.com
C0086
Priory Analysts Ltd The Pinnacle, 160 Midsummer Blvd Milton Keynes, MK9 1FF, United Kingdom
EC REP
3
CLEMENTS
Contents
Contents
Specifications .................................................. 4
Transportation and Storage ............................ 5
Installation and Operation .............................. 6
Spares Parts………………………………. .............. 7
Troubleshooting………………………………………. 8
Cleaning .......................................................... 9
Disassembly .................................................... 10
Warranty .......................................................... 14
4
CLEMENTS
Specifications
Vacuum Range
0 to -100 kPa, 0 to -750 mmHg
Flow Rate
0 to 35 Litres of Free Air Per Minute
Lever No Lever
Height
100 mm 40 mm
Width
75 mm 75 mm
Depth
80 mm 80 mm
Weight
300 g 250 g
Duty Cycle
Continuous
Ambient Temperature
+5°C to 35° C
Standard Conditions
25°C, Sea Level, 101 kPa
Class
Class I (EU Class IIa)
ARTG
174693
GMDN
14325
Specifications
Intended Use
Connect two pieces of medical gas equipment to a single medical gas terminal unit.
5
CLEMENTS
Transportation and Storage
Environmental conditions for transportation and storage are shown in the following table.
Parameter Minimum Maximum
Temperature 10ºC 40ºC
Humidity 60% RH 95% RH
Barometric Pressure 700 mBar 1060 mBar
Warning Symbols Legend
The warning symbols marked on the equipment and their meanings are shown as follows.
Caution, consult accompanying documents
Transportation and Storage
Waste Materials
The contents of the collection jars, suction tubing, bacteria filter, internal exhaust filter may contain biohazard wastes. Handle using safe handling procedures, which may include the use of rubber gloves and eye protection, and dispose of according to local protocols for biohazard materials.
Recycling
At the end of their service life, the Nozzle should be dismantled if necessary, and returned to a local materials recycling centre.
6
CLEMENTS
Description
The Clements Duplex Adaptor allows the connection of two pieces of equipment to a single wall terminal unit.
Clements Duplex Adaptors are available to connect to most types of wall outlet.
Installation and Operation
Carefully examine the Dupledx Adaptor for any visual signs of damage that might have occurred during shipment. Attach the adaptor to the wall outlet with the index handwheel or relevant connector.
1.
Ensure any equipment is turned off before connecting to the duplex adaptor.
2.
Select the outlet to use by moving lever (lever model only) fully to corresponding position.
Installation and Operation
NOTE:
Only ONE piece of equipment can be in use at any given time. Ensure that equipment connected to the other outlet is switched off.
Item Description
SUC 89660 Duplex Suction Adaptor without Lever, Ring Index
SUC 89661 Duplex Suction Adaptor with Lever, Ring Index
7
CLEMENTS
Spare Parts
SUC 89771 Ring Index Connector Kit for Wall
Suction Products ( Handwheel, 1/8 BSP Threaded Nipple, O-Ring)
SUC 89240 019 Puritan Bennett Connector with 1/8 BSP Thread
SUC 89240 074 BS MKIV Connector with 1/8 BSP Thread
SUC 89250 006 Drager Connector with 1/8 BSP Thread
SUC 89660 Duplex Suction Adaptor with Lever
SUC 89661 Duplex Suction Adaptor Without Lever
SUC 89660 081 User Manual for Duplex Adaptors
Select from a range of Medical Suction Tubing, Collection Jars, Bung Assemblies, and Handpieces
Spare Parts
8
CLEMENTS
Fault Check Rectify
No Vacuum / Flow On / Off Lever Ensure turned on
Wall outlet blocked Refer to engineering
dept.
Body blocked Strip and clean
Troubleshooting
Troubleshooting
9
CLEMENTS
Cleaning
Cleaning
Clean using a pH neutral disinfectant for wiping or immersion cleaning. Flush after immersion using distilled water and dry before reassembly of unit.
Cleaning Procedure
Tools and Materials Required
Allen key set, imperial
Vacuum grease
Can of spray, Dow Corning Molykote D-321R Sealer
Hand press and fixture for holding body
Cleaning
10
CLEMENTS
Disassembly Procedure
1. Remove unit from wall.
2. Remove the hand wheel by inserting an allen key into the brass nipple in the centre of the hand wheel. Make sure the allen key is pushed home into the brass nipple before unscrewing.
4. Remove the Sel-Lok pin , disc springs and O-ring using a hand press and fixture.
5. Push the plug out by gently twisting and pushing. Once the plug is out, gently clean the plug with a soft brush using a degreaser. Wash and blow-dry. Use the same care when cleaning out the bore in the nozzle body.
6. Lightly coat the plug with Molykote surface spray and let dry.
7. Apply a light coat of vacuum grease to the body bore.
8. To assemble - reverse the order
9. To test - lever should be firm and smooth to turn, vacuum when tested should read the same as the vacuum source, flow should have a max of 2-3 lpm loss only.
10. Clean any vacuum grease off the body.
Cleaning Procedure
11
CLEMENTS
Notes
12
CLEMENTS
Notes
13
CLEMENTS
Notes
14
CLEMENTS
Warranty
BMDi TUTA Healthcare Pty Limited ("BMDi TUTA Healthcare") warrants that this product is free from defects in workmanship and materials for a period of 12 months from the date of shipment by BMDi TUTA Healthcare or its authorised agent to the purchaser. Subject to the conditions of this warranty, if the product fails to operate for any reason within the warranty period and the product is returned to the place of purchase at the purchaser's expense, BMDi TUTA Healthcare will repair or replace the product free of charge.
If a valid warranty claim is made within 30 days from the date of shipment, then BMDi TUTA Healthcare will also reimburse the purchaser for reasonable freight costs in returning the product to the place of purchase.
Conditions of Warranty
1. The product must be returned to the place of purchase with proof of purchase.
2. This warranty is only available to the original purchaser of the product.
3. The product must not have had its serial number removed, defaced or changed, its casing opened, its power supply altered or have been tampered with in any other way.
4. This warranty does not cover :
inadequate or incorrect site preparation;
improper installation;
connection to the wrong voltage;
failure of the product due to misuse;
the use or operation of the product outside of the physical,
electrical or environmental specifications of the product;
use in a manner or environment in which the product is not
designed to be used;
improper adjustment, calibration or operation by the purchaser;
the use of accessories including consumables, hardware or
software which were not manufactured or approved in writing by BMDi TUTA Healthcare;
Warranty
15
CLEMENTS
any modifications of the product which were not authorised in writing by BMDi TUTA Healthcare;
any contamination or leakages caused or induced by the purchaser; and
inadequate or improper maintenance of the product.
5. This warranty does not cover normal wear and tear.
6. BMDi TUTA Healthcare will not be responsible for damage or loss caused during shipping.
7. In Australia, apart from any warranties implied by the Trade Practices Act 1974 all other warranties expressed or implied and whether arising by virtue of statute or otherwise are hereby excluded.
8. Outside Australia, all other warranties expressed or implied and whether arising by virtue of statute or otherwise (including any warranties implied by the Vienna Convention) are hereby excluded.
9. BMDi TUTA Healthcare' obligations under this warranty are limited to the repair or replacement of the product, within the terms of this warranty and the total liability of BMDi TUTA Healthcare for loss or damage of every kind whether arising pursuant to the terms of the sale of the product or otherwise in connection with the product is limited to the amount paid by the purchaser to BMDi TUTA Healthcare for the product.
10. Apart from any liability imposed by Part VA of the Trade Practices Act, BMDi TUTA Healthcare accepts no other liability for any loss or damage occasioned (including consequential loss or damages) in any way as a result of the use of the product.
11. The warranty does not extend to cover damage to the following parts as they are inherently prone to wear :
motor brushes
12. This warranty does not extend to cover corrosion due to any cause nor to any damage to painted or anodised surfaces.
13. BMDi TUTA Healthcare will give the purchaser the benefit of any manufacturer's warranty in respect of any components in the product which were not manufactured by BMDi TUTA Healthcare, if such a manufacturer's warranty is available.
Warranty