![](/html/bb/bb45/bb45db6bd803ded3fa39462ee93807fb6859304dac1a50d34be19341b2e874c2/bg1.png)
Instruction Manual
Multi Sub Electrophoresis Systems
MSMIDI96
MSMIDI96ST
MULTISUB4
![](/html/bb/bb45/bb45db6bd803ded3fa39462ee93807fb6859304dac1a50d34be19341b2e874c2/bg2.png)
Contents:-
Page
1) Safety Instructions 3
2) Packing Lists 4
3) Usage Guidance and restrictions 6
4) Care and Maintenance 7
5) Setting Up 8
6) Gel Preparation 9
7) Gel Pouring 10
8) Gel Running 11
9) Gel Staining 12
10) Solutions 13
11) Combs 14
12) Warranty 16
![](/html/bb/bb45/bb45db6bd803ded3fa39462ee93807fb6859304dac1a50d34be19341b2e874c2/bg3.png)
SAFETY PRECAUTION
WHEN USED CORRECTLY, THESE UNITS POSE NO HEALTH RISK.
HOWEVER, THESE UNITS CAN DELIVER DANGEROUS LEVELS OF ELECTRICITY
AND ARE TO BE OPERATED ONLY BY QUALIFIED PERSONNEL FOLLOWING THE
GUIDELINES LAID OUT IN THIS INSTRUCTION MANUAL.
ANYONE INTENDING TO USE THIS EQUIPMENT SHOULD READ THE COMPLETE
MANUAL THOROUGHLY.
THE UNIT MUST NEVER BE USED WITHOUT THE SAFETY LID CORRECTLY IN
POSITION.
THE UNIT SHOULD NOT BE USED IF THERE IS ANY SIGN OF DAMAGE TO THE
EXTERNAL TANK OR LID.
THESE UNITS COMPLY WITH THE STATUTORY CE SAFETY DIRECTIVES:
73/23/EEC: LOW VOLTAGE DIRECTIVE: IEC 1010-1:1990 plus AMENDMENT 1:1992
EN 61010-1:1993/BS EN 61010-1:1993
PACKING LISTS:
![](/html/bb/bb45/bb45db6bd803ded3fa39462ee93807fb6859304dac1a50d34be19341b2e874c2/bg4.png)
MSMIDI96
Units include tank, lid and electrodes and include the following accessories:-
Tray Tray Dams
Combs and
comb block
Loading
Guides
Cables
MSMIDI96
MS10-UV96 10 x
12cm (W x L)
MS10-UVDAM
Pack of 2
MSMIDI96-8-1-CB
MS10-LG – Strips
MS10-WP – Platform
CSL-CAB
MSMIDI961.5
MS10-UV96 10 x
12cm (W x L)
MS10-UVDAM
Pack of 2
MSMIDI96-8-1.5-CBMS10-LG – Strips
MS10-WP – Platform
CSL-CAB
MSMIDI96/2M
MS10-UV96 10 x
12cm (W x L)
MS10-UVDAM
Pack of 2
MSMIDI96-81/2M-CB
MS10-LG – Strips
MS10-WP – Platform
CSL-CAB
MSMIDI96/1.5/2M
MS10-UV96 10 x
12cm (W x L)
MS10-UVDAM
Pack of 2
MSMIDI96-8-
1.5/2M-CB
MS10-LG – Strips
MS10-WP – Platform
CSL-CAB
MSMIDI96ST
Units include tank, lid and electrodes and include the following accessories:-
Tray Tray
Dams
Combs and
comb block
Loading
Guides
Cables
MSMIDI96ST
MS10-UV96ST 10 x
24cm (W x L)
MS10UVDAM
Pack of 2
MSMIDI96ST-8-1CB
MS10-LG – Strips
MS10-WP –
Platform
CSL-CAB
MSMIDI96ST1.5
MS10-UV96ST 10 x
24cm (W x L)
MS10UVDAM
Pack of 2
MSMIDI96ST-8-1.5CB
MS10-LG – Strips
MS10-WP –
Platform
CSL-CAB
MSMIDI96ST/2M
MS10-UV96ST 10 x
24cm (W x L)
MS10UVDAM
Pack of 2
MSMIDI96ST-81/2M-CB
MS10-LG – Strips
MS10-WP –
Platform
CSL-CAB
MSMIDI96ST/1.5/2
M
MS10-UV96ST 10 x
24cm (W x L)
MS10UVDAM
Pack of 2
MSMIDI96ST-8-
1.5/2M-CB
MS10-LG – Strips
MS10-WP –
Platform
CSL-CAB
MultiSUB4
Units include tank, lid and electrodes and include the following accessories:-
![](/html/bb/bb45/bb45db6bd803ded3fa39462ee93807fb6859304dac1a50d34be19341b2e874c2/bg5.png)
Trays Combs Caster Cables
CSL-MULTISUB4
4 x MSUB4UV18 8
x 18cm (W x L)
8 x MSUB4-18/8-
1.5 1.5mm, 18 and
8 sample
- CSL-CAB
CSLMULTISUB4EXCAS
4 x MSUB4UV18 8
x 18cm (W x L)
8 x MSUB4-18/8-
1.5 1.5mm, 18 and
8 sample
1 x MSUB4EXCASTER
External Caster For Msub4 (4
Trays)
CSL-CAB
The packing lists should be referred to as soon as the units are received to ensure that
all components have been included. The unit should be checked for damage when
received.
Please contact your supplier if there are any problems or missing items.
Usage Guidance and restrictions:
• Maximum altitude 2,000m.