ClearWater LPSA20, LPSA60 Installation And Operation Manual

LPSA Air Dryer
Installation and Operation Manual
LPSA20 and LPSA60
ClearWater Tech, LLC.
Integrated Ozone Systems
850-E Capitolio Way, San Luis Obispo, Ca 93401 • 805-549-9724 • Fax: 805-549-0306 • E-mail: service@cwtozone.com • www.cwtozone.com
Copyright © 2007 - ClearWater Tech, LLC • Reproduction of any kind is prohibited • LIT205 • REV060810
Page 2
Cautions, Warnings and Hazards
Do not allow rain or condensation to contact the LPSA Air Dryer. The LPSA Air Dryer is not weatherproof. It must be operated indoors or in an enclosure in a non-condensing environment.
The LPSA Air Dryer should be installed and operated per the Compressed Gas Association Guide P-8.1, “Safe Installation and Operation of PSA and Membrane Oxygen and Nitrogen Generators.”
Patents, Trademarks, and Copyright
The LPSA Series Air Dryers are protected by the following US Patents: 4,925,464 5,112,367 5,114,441 5,268,021 5,366,541 5,593,478 5,370,778 Re. 35,099 Other patents pending.
ATF® is a registered trademark of SeQual Technologies, Inc.
Page 3
Introduction
The operation of the LPSA Air Dryer is based on the pressure swing adsorption (PSA) cycle using a synthetic zeolite molecular sieve. The LPSA Air Dryer is capable of delivering dry air flows up to 20 standard cubic feet per hour (SCFH) for LPSA20, and 60 SCFH for LPSA60 at
60°F to 90°F dewpoint at rated conditions. The main components of the LPSA Air Dryer are a SeQual ATF LPSA Module and an oil-less air compressor.
Installation
IMPORTANT: There are packaging materials that must be removed from under and around the
compressor. Do not attempt to operate the LPSA Air Dryer without removing these packaging materials as damage may result.
Ensure that there is sufficient access space around the LPSA Air Dryer so that normal maintenance and service can be performed. Also ensure that there will be a free flow of cooling air around the compressor. Connect the unit to a grounded power source rated for the voltage and current requirements stated on the label on the unit.
IMPORTANT: The location of the LPSA Air Dryer must be well ventilated. Refer to the recommendations in the Compressed Gas Association Guide P-8.1, “Safe Installation and Operation of PSA and Membrane Oxygen and Nitrogen Generators.” Contact ClearWater Tech if further assistance is needed.
IMPORTANT: Choose a location for the LPSA Air Dryer that does not allow rain or condensation to contact the unit.
Dry Air Hook-up
The dry air connection is a 1/8 inch female National Standard Pipe Thread (NPT) and is located on the front of the LPSA Air Dryer. The hex nut bulkhead fitting should be stabilized with a 7/8 inch wrench to prevent rotation when making your connection to the unit.