Clearfield FieldShield D-ROP, FieldShield FLATdrop Installation Manual

FieldShield D-ROP
Installation Manual
______________________________________________________
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
Installation Manual
Application 3 Description 3 Accessories 3 Technical Specications 4 Packaging 5 Required Tools 5 Installing into YOURx-Terminal 6 Installing into YOURx-TAP 8 Reducing Duct Length 9 Connector Cleaning Procedure 12 Drop Cable Options 15 Standard Warranty 16 Proprietary Notice 17 Technical Support 17
_________________________________________________________
2
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
__________________________________________________________
Application
Building upon the restoration promise of FieldShield Pushable Fiber, FieldShield D-ROP is a preconnectorized drop cable delivered to market pre-placed in a 7mm microduct. The FlexConnector snaps into the FlexPort providing an air-tight, water-tight connection between the YOURx-TAP and YOURx-Terminal. Installed by the contractor as a single-pass deployment, FieldShield D-ROP also provides ease of restoration. In the event of a future
ber cut, a eld technician easily identies the cut area, and utilizes a simple
coupler and a FieldShield Fiber Assembly to restore service.
Description
D-ROP cable presents the same footprint as a at drop cable with the added advantage of being restorable. Just like traditional FieldShield microduct and ber, ber cuts are located, repaired and a new ber assembly is pulled from point A to B with a pre-terminated LC assembly. In the event that an LC is not used, blunt ber is pulled and completed with a
fuse-on connector minimizing costs and time to restore the service outage. The FlexConnector is plugged directly into the FieldShield YOURx-Terminal or YOURx-TAP FlexPort, providing a completely protected pathway from the access point
directly to the premise, business or antenna with the option for restoration after accidental ber cut. D-ROP does not have the slack storage challenges that a at drop presents because the duct slack can be peeled or removed leaving only the 900um pre-terminated/tested ber assembly.
Installation Manual
Accessories
Part Number Description FS-DUCT-OPENER Microduct Opener, D-ROP
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
3
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
Installation Manual
Technical Specications
FieldShield D-ROP
Length Up to 2000 foot spool (-0/+5%)
Outside Diameter 0.276” (7mm)
Inside Diameter 0.138” (3.5mm)
Wall Thickness 0.069” (1.75mm)
Ovality ≤ 5%
Material HDPE
_________________________________________________________
Installed Fiber 900 μm singlemode bend insensitive ber
Connector Style SC or LC
Operating Temperature -40°F to 176°F (-40°C to 80°C)
Color Orange or Black
Tone Wire Copper
Markings Part number, lot number, footage markers every two feet
Breakout Length 12 Inches
Min. Bend Radius 4.75” (120)
4
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Manual 018958 REV C - Oct 2017
Packaging
FieldShield D-ROP
__________________________________________________________
Installation Manual
Ship along connector parts twist tied to duct.
Required Tools
Find No. Tool Image
001 Pliers
002 Deburring Tool
Do not remove zip tie and protective covering until duct has been direct buried.
003 Wire Snips
004 Duct Opener
005 Rotary Cutter
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
5
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
Installation Manual
Installing into YOURx-Terminal
Preparing Terminal
_________________________________________________________
Step 1: Bury Duct
Bury cable according to best practices for chosen drop method
(Figure 1).
NOTE: Do not remove protective cov-
ering until duct has been buried.
Figure 1
Seating X-Connector
Step 2: Remove Flex Port Tab
Use a pair of pliers to snap off tab of selected Flex Port
(Figure 2).
Figure 2
Step 3: Ream Port
Use appropriate tool (we recommend deburring tool) to ream and chamfer edges of port
(Figure 3).
Figure 3
Step 1: Feed Through Flex Port
Guide preconnectorized ber
(unassembled) into YOURx-Terminal through Flex Port
(Figure 1).
Figure 1
6
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Step 2: Seat FlexConnector
Once ber is through,
seat FlexConnector into FlexPort
(Figure 2)
Figure 2
Manual 018958 REV C - Oct 2017
__________________________________________________________
Assemble Connector Housing
FieldShield D-ROP
Installation Manual
Step 1: Align Connector Housing
Align housing keyway with dot and push on outer housing
(Figure 1).
Figure 1
Connect Fiber to Flex Cartridge
Step 2: Assemble Housing
Push outer housing until it clicks into place
(Figure 2).
Figure 2
Step 1: Seat Connector into FlexCartridge
Connect Fiber to selected port in the FlexCartridge
(Figure 1 & Figure 2).
Figure 1 Figure 2
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
7
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
!
Installation Manual
Installing into YOURx-TAP
_________________________________________________________
Step 1: Feed through Port
Guide unassembled preconnectorized
ber into YOURx-TAP FlexPort.
(Figure 1).
Figure 1
Step 2: Seat FlexConnector
Once ber is through, seat Flex
Connector into FlexPort.
(Figure 2)
Figure 2
Step 3: Assemble SC Connector
Once FlexConnector is seated into FlexPort, assemble SC Connector Housing.
(Figure 3).
Figure 3
When entering the YOURx-TAP DO NOT assemble SC Connector Outer Housing until ber has been passed through the port. Fully connectorized ber will not pass through port.
IMPORTANT
8
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Manual 018958 REV C - Oct 2017
__________________________________________________________
Reducing Duct Length
FieldShield D-ROP
Installation Manual
Step 1:
Snip zip tie and remove the protective shipping corrugate (Figure 1).
Step 4:
Bend duct at scoring to break free
(Figure 4).
Step 2:
Working in 6 foot sections or less, determine desired length and mark
duct (Figure 2).
Figure 2Figure 1
Step 5:
Use wire cutters to cut strength members, taking care not to sever
ber (Figure 5).
Step 3:
Use rotary cutter to score duct
(Figure 3).
Figure 3
Step 6:
Remove FLEX connector by pressing the attached removal tool into the base of the connector (Figure 6).
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Figure 5Figure 4
Manual 018958 REV C - Oct 2017
Figure 6
9
FieldShield D-ROP
Installation Manual
_________________________________________________________
Step 7:
Remove ber retainer rubber stop from
the end of the duct (Figure 7).
Figure 7
Step 10:
Ensure ber is outside of mechanism
(Figure 10).
Step 8:
Insert tool blade into duct (Figure 8).
Step 11:
Turn handle to split duct and allow
ber to fall out. (Cut support member if it interferes with opener’s path.)
(Figure 11).
Step 9:
Squeeze handle to engage traction gear. (Figure 9)
Figure 9Figure 8
Step 12:
To nalize the last 1/4 inch of the split,
pull duct across blade by hand
(Figure 12).
Figure 10 Figure 12Figure 11
10
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
__________________________________________________________
Installation Manual
Step 13:
Slide ber retainer rubber stop along ber and seat into new duct end
(Figure 13).
Figure 13 Figure 15Figure 14
Step 14:
Silde FLEX connector along ber and
seat onto new duct end (Figure 14).
Step 16:
For longer splits (up to 10 feet) a hand drill on a low gear setting may be used in place of the hand crank
(Figure 16).
Step 15:
The SC connector is now ready to pass through a FLEX port and have the outer housing assembled
(Figure 15).
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Figure 16
11
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
Installation Manual
Connector Cleaning Procedure
Whether factory terminated or eld spliced, clean connectors are essential
for proper system operation. Even the smallest dust particle can cause transmission problems, so for optimal network performance, inspect and if necessary, clean all connectors and adapters prior to mating.
I.B.Y.C…Inspect Before You Connect!
ALWAYS inspect the connector rst thing with a clean ber scope inspect
the pair. Three types of contamination require different cleaning techniques. The use of Chemtronics end face and bulkhead cleaning products and techniques ensures a clean end face, no matter the type of contamination.
These are Cleareld recommended products/application. Use the product
you feel will complete your cleaning procedures. Create a “best practice” for your company and follow those procedures.
_________________________________________________________
Figure 1
**NOTE: It is NOT recommended to use IPA to clean the end-face.
Cleaning the end-face…but not just the end-face
• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen. Figure 1
• Apply small amount of precision cleaner (about 1” in diameter) with Elec­tro-Wash MX pen on to one end of the wipe. Figure 2
• Hold end face 90 degree. Adjust for APC connection by slightly tilting the container or end face. Angle is correct when no drag is left on the end face.
Figure 3
• Draw end face from wet to dry part of the wipe 3 times. Use just enough pressure to ensure complete contact between end face and the wipe.
DO NOT retrace previous step.
Figure 2
Figure 3
12
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Manual 018958 REV C - Oct 2017
__________________________________________________________
CLEAN THE FERRULE…Lightly moisten the ber optic swab (2.5mm/38542F or 1.25mm/38040) by spotting a small amount (about 1”) of Electro-Wash PX or Electro-Wash MX pen onto the QBE-2. Hold the swab, 1 side down to the wetted area and hold for a count of 1-2-3-4-5.
Figure 4
• Insert swab into side of ferrule, wet side to the ceramic ferrule and circle around 2-3 times and remove. Turn swab to dry side and repeat.
Figure 5
FieldShield D-ROP
Installation Manual
Cleaning the mate through a bulkhead adapter AND the adapter itself!
• Lightly moisten the ber optic swab(2.5mm/38542F or 1.25mm/38040)
by spotting a small amount (about 1”) of Electro-Wash PX or Elec­tro-Wash MX pen onto the QBE-2. Hold the tip of the swab onto the wetted area and hold for a count of 1-2-3-4-5.
• Insert the swab into the adapter to the connector, press lightly against the connector, twist 2-3 times, remove and discard.
• Dry with a second dry swab.
• Inspect (re-clean if necessary) and test for signal strength.
• Use additional swabs to clean inside the actual adapter. Moisten swab, like above, insert through hole and remove while twisting. Figure 6
Figure 4
Figure 5
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Figure 6
13
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
Installation Manual
Cleaning an MPO/MTP Connector
Female Connector
• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen and apply small amount of precision cleaner (about 1” in diameter) with Elec­tro-Wash MX pen on to one end of the wipe. Figure 1
• Hold end face 90 degree. Adjust for APC connection by slightly tilting the container or end face. Angle is correct when no drag is left on the end face. Figure 2
_________________________________________________________
Figure 1
Male Connector
• Lightly moisten the ber optic swab (CC505F) like above, moistening 1
side.
• Place swab, wet side down at one end of connector end-face and draw
across in a diagonal sweep (ie: from ber 1 up and across to ber 12). Turn swab over to dry and draw back from ber 12 to ber 1. Figure 3
BEFORE cleaning any connector…be sure you know what type of con­taminate you are cleaning…dry? Fluidic?...All the available products are good, it’s the process that you need to be aware of. Using a dry cleaning method to clean “dirt” can lead to scratching of the end-face. Learn the process of cleaning properly!
Figure 2
Figure 3
14
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Manual 018958 REV C - Oct 2017
__________________________________________________________
Drop Cable Options
FieldShield D-ROP
Installation Manual
Product
Name
FieldShield
FLATdrop
FieldShield
D-ROP
FieldShield
FLEXdrop
Cable
Jacket
Outdoor Yes -40° to 176°F No Black Yes
Outdoor Yes -40° to 176°F Yes
Indoor
(Plenum
Rated)/
Outdoor
UV Temperature
Yes -40° to 176°F Yes
FieldShield
Connector
Jacket
Color
Black/
Orange
Black/
White
Can be stapled
Yes
Yes
Best
Application
For use when fast installation
and low up-front cost is most
desired feature.
For use when a single pass and restorable solution at a
competitive price is ideal.
For use when a premium
product that has maximum
workability, exibility and
restorability is desired.
FieldShield
(Classic)
Outdoor
in Duct
FieldShield
StrongFiber
Indoor/
Outdoor
in Duct
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Yes in
Duct
Yes in
Duct
-40° to 176°F Yes Black Yes
-40° to 176°F Yes Black
Manual 018958 REV C - Oct 2017
Yes in
Duct
For use when the distance
from the access point to the
SFU/MDU is longer than
normal and a more rigid solu-
tion is required to maintain
restorability for drops longer
than 300 feet.
For use when a reusable
pathway is needed and
maximum slack storage is
desirable.
15
FieldShield D-ROP
Installation Manual
Standard Warranty
Cleareld warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and service, subject to exceptions stated herein. Product purchased is warranted as follows: Cleareld designed and branded Products are warranted for ve (5) years: Products manufactured by Cleareld to customer prints and/or specications are warranted for one (1) year; and any Product Clear­eld acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s
pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.
Warranty Claim Procedure
If any Product purchased from Cleareld is found defective under the above warranty, the following basic procedure must be followed:
1. Customer must contact Cleareld and obtain a Return Materials Authorization
2. Following authorization, the Customer ships the product-freight collect-to Cleareld’s manufacturing facility
3. Cleareld shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus­tomer’s site, freight prepaid
Note: If the Product is not found to be defective at Cleareld, the product will be returned to the Customer and the customer billed for freight in both
directions.
_________________________________________________________
Limitations of Warranty
Correction of defects by repair or replacement, at the option of Cleareld Inc, shall constitute the exclusive sole remedy for a breach of this limited warranty. Cleareld shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost prots, loss
of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or exclusive remedy to achieve its essential purpose, or otherwise.
Cleareld will not be responsible for any labor or materials costs associated with installation or incorporation of Cleareld products at customer sites, including any costs of alteration, replacement or defective product, or any eld repairs.
Other Limitations
1. Cleareld assumes no warranty liability regarding defects caused by:
2. Customer’s modication of Product, excepting installation activities described in Cleareld documentation
3. Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Cleareld, or any de­fects suffered during shipping where the Product has been re-packaged
4. Customer’s installation or maintenance, excepting activities described in and performed in accordance with Cleareld documentation
5. Customer’s improper or negligent use or application of Product
6. Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil
commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Cleareld
16
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net
Manual 018958 REV C - Oct 2017
FieldShield D-ROP
__________________________________________________________
Proprietary Notice
About FieldShield Product Line Application
Information contained in this document is copyrighted by Cleareld, Inc. and may not be duplicated in full or part by any person without prior written approval of Cleareld, Inc.
Its purpose is to provide the user with adequately detailed documentation to efciently install the equipment supplied. Every effort has been made to
keep the information contained in this document current and accurate as of the date of publication or revision.
However, no guarantee is given or implied that the document is error free or that it is accurate with regard to any specication.
Technical Support
Cleareld, Inc. can be contacted for any issues that arise with the supplied product.
If you need to return the supplied product, you must contact the Cleareld, Inc. Customer Service Department to request a Returned Materials
Authorization (RMA) number.
Installation Manual
Cleareld, Inc.
7050 Winnetka Ave N Minneapolis, MN 55428
Toll Free: 800.422.2537 Phone: 763.476.6866 Fax: 763.475.8457
Customer Support: sales@clfd.net Technical Support: techsupport@clfd.net
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • techsupport@clfd.net