Claudgen HE8326-33, HE7433-33 Installation, Operation And Maintenance Instructions

I
NSTALLATION, OPERATION AND MAINTENANCE
I
NSTRUCTIONS FOR
Claudgen Screen-Zone
Warm Air Curtain Heater
Catalogue Number HE7433-33 9Kw Catalogue Number HE8326-33 6Kw
For single or 3 phase supply
P
LEASE RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE
CCCC
ONSORT
ONSORT
ONSORT ONSORT
R
EGISTERED OFFICE
M
ILFORD HAVEN, PEMBROKESHIRE,
TEL: 01646 692172 FAX: 01646 695195
WEB: www.consortepl.com E
EEEE
QUIPMENT
QUIPMENT
QUIPMENT QUIPMENT
: T
HORNTON INDUSTRIAL ESTATE
MAIL
PPPP
RODUCTS
RODUCTS
RODUCTS RODUCTS
SA73 2RT
: technical@consortepl.com
LLLL
TD
TD
TDTD
41000981 Iss 09
MODEL
Fig 1
OUTLINE DRAWING
This unit is a 1035mm 6 or 9kW air curtain heater designed for mounting above entrances but may also be used as a space heater. It is supplied complete with remote mounting control box.
MOUNTING
When mounted over a standard shop doorway the unit should be fitted as low as possible and not more than
2.3 meters from ground level. A single unit will provide reasonable coverage for a one metre doorway, and for wider doorways units can be mounted end to end.
The unit should be positioned so that the airflow is not obstructed by any part of the doorframe. When installed the top of the heater case should be a minimum of 200mm from the ceiling.
75
880
INSTALLATION
Carefully unpack the unit and remove the top cover fixing screws. The heater may be mounted using the mounting bracket provided.
Loosen mounting screws, allowing the mounting bracket to be removed from the unit. Making sure that the mounting bracket is horizontal, fix the bracket to the wall using 4 x No 8 wood screws.
Place the unit on the mounting bracket ensuring the washers are spaced as shown on Fig 2 (a plain washer either side of the mounting bracket).
Tighten screws to hold the unit at the required angle.
Fig 2 WALL BRACKET ASSEMBLY
The heater may also be mounted directly onto a suitable wall or bearer by four No. 8 wood screws through the holes provided in the back of the unit casing. Keyhole slots are provided for the top two fixings (fig 1).
ELECTRICAL CONNECTIONS
The heater is suitable for connection to a 400-415 volt 3 phase 50Hz supply. With modification the unit can also be on a 230-240 volt 50Hz supply. For 230-240 volt single phase operation, link terminals L1, L2 and L3 on the main input terminal block and connect the supply to L. The heater consumes approximately 6 or 9kW on the full heat setting. The connections to be made between the heater and the remote control box are shown in Fig 3 (see back page). An earth terminal is adjacent to the terminal block and is clearly marked with the symbol . For safety reasons a good earth connection must ALWAYS be made to the heater and control box.
The unit must be wired in accordance with IEE regulations for the Electrical Equipment of Buildings and the installer should ensure that a suitable fused isolating switch is connected in the mains supply.
REMOTE CONTROL BOX CONNECTIONS
CONTROLS
The unit is designed to provide 2 levels of heat, 4.5kW and 9kW for HE7433, 3kW and 6kW for HE8326 together with 2 fan speeds, normal and boost. The remote control box houses 4 single pole switches to give the following functions:
SWITCH 1 (left-hand) ON/OFF SWITCH 2 FAN SPEED CONTROL SWITCH 3 ½ HEAT ON/OFF SWITCH 4 ½ HEAT ON/OFF
FRONT VIEW
MAINTENANCE
ALWAYS ENSURE THAT THE MAIN EXTERNAL ELECTRICITY SUPPLY IS SWITCHED OFF BEFORE SERVICING OF THIS SCREEN-ZONE HEATER.
To obtain the best results from the heater it is essential to avoid the accumulation of dust and dirt within the unit and on the inlet and discharge grilles. Regular cleaning is necessary with particular attention to the fronts and backs of the fan motor blades. Cleaning of the fan is best carried out with a soft brush.
THERMAL CUT-OUT
The units are protected from overheating in the event of fan failure or an obstruction of the free airflow, by thermal cut outs. If this happens the thermal cut outs effectively switch off the appliance. The appliance will not operate until the thermal cut outs are manually re-set. This should be done by a competent electrician.
TO REPLACE A SWITCH IN THE CONTROL BOX
a) Switch off the mains supply b) Remove the switch box cover. c) Disconnect the wiring to the switch. d) Release the spring clips and push out the switch. e) Fit the replacement switch, reconnect the wiring and
replace the cover.
SPARES
It is essential when ordering spares or replacement parts to state the model number HE7433 and the serial number on the rating place fixed to the top of the unit.
NB: DO NOT COVER ANY OF THE AIR INLET OR OUTLET GRILLES AT ANY TIME.
In the interest of progress the Company reserves the right to vary specifications from time to time without notice. The material listed is offered subject to the Company’s General Conditions of Sale, a copy of which can be obtained on request.
41000981 Iss 09