Clary Corporation SN1000, SN1250, SN1500, SN2000 Owners Operating & Maintenance Manual

OWNER'S
OPERATING &
MAINTENANCE
MANUAL
UNINTERRUPTIBLE POWER SYSTEM
GLOBAL SN SERIES UPS
1,000VA THROUGH 2,000VA
MODELS:
Manufactured by
NOVA POWER SOLUTIONS, Inc.
11367 Sunset Hills Road, Reston, VA 20190
THE CONTINUOUS POWER COMPANY
Information contained herein is the property of Clary Corporation, is proprietary, confidential, and not to be disclosed,
disseminated or used except for the purpose provided by
CLARY CORPORATION
P/N 510-12580 A RD-12/29/03
Tel: (703) 742-0000 Fax (703) 742-4003
Sold Exclusively Through
email: nova@novapower.com
THE CONTINUOUS POWER COMPANY
TABLE OF CONTENTS
TITLE PAGE
TABLE OF CONTENTS 1
INTRODUCTION 3
TECHNICAL DESCRIPTION 4
PACKAGING 6
PHYSICAL DESCRIPTION 7
SUMMARY OF INDICATORS AND CONTROLS 11
INSTALLATION 12
OPERATION 13
SIGNALS AND INTERFACING 14
SPECIFICATIONS 15
CARE AND MAINTENANCE 17
SERVICE AND REPAIR 18
WARRANTY 19
INTRODUCTION
THE CONTINUOUS POWER COMPANY
ongratulations! You have selected the highest quality protection for your continuous
C
power needs. This unit offers a quiet and compact package with superior performance
you can depend on. You now own a SN Series
Continuous Power System (CPS) which is an all Digital Technology product manufactured by Clary
Corporation, the first name in uninterruptible power system (UPS) reliability. The Continuous Power System is the highest order in the hierarchy of UPS products. When power problems occur, there can be no compromising the reliability of your power solution. The SN Series Continuous Power System is your complete power solution.
IMPORTANT SAFETY INSTRUCTIONS,
SAVE THESE INSTRUCTIONS
This symbol indicates that dangerous voltage constituting a risk of electrical shock is present within the unit.
!
This Users Manual is provided with your new SN Series unit. It will enhance your understanding of
the product and its functions. Read this handbook carefully in the order it is presented prior to operating your unit. This will save you time and effort in your installation and application. The illustrations will also familiarize you with this unit’s operating modes and indications. Always operate the unit within the guidelines and specifications given to maximize the unit's efficiency and lifetime. Also, your understanding of the product is essential in providing you years of service for your continuous power requirements.
This unit has been manufactured and tested to meet specific safety standards. It meets UL and FCC requirements and complies with safety performance standards.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION
RISK OF ELECTRIC
SHOCK DO NOT OPEN
!
This manual contains important safety instructions that should be followed during installation and maintenance of the UPS and batteries. Be aware of the following symbols and their meaning as they appear throughout the manual:
This equipment generates and uses radio frequency energy and if not installed and used properly in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. All units in this manual have been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a commercial installation. However, there is no in a particular installation. If this equipment does cause interference to radio and television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
guarantee that interference will not occur
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How To Identify and Resolve Radio-TV Interference Problems" This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004000003454.
Reorient the receiving antenna.Relocate the UPS wi th respect to the receiver.Move the UPS away from the receiver.Plug the UPS into a different outlet so that the UPS
and receiver are on different branch circuits.
Page 3
TECHNICAL DESCRIPTION
THE CONTINUOUS POWER COMPANY
he SN Series Continuous Power System (CPS) is a revolutionary new concept in total power protection and management. The SN
T
Series is a microprocessor-based UPS that now allows the user to set most of the control feature parameters. By directly linking a personal computer to the SN Series RS232 port, frequency settings and operation, alarm signals, load switching, fan operation, etc. can all be programmed to meet specific application requirements.
The SN Series is a true on-line, continuous power UPS. In the tradition of Clary products, the SN Series generates the same high quality and proven reliability to provide the best power protection available for today’s critical applications.
In keeping with state-of-the-art design, the power electronics are completely governed by an on-board microprocessor. Given the powerful memory capability of today’s microcontrollers, this microprocessor has evolved the UPS into an all-in­one complete power distribution and monitoring center. Not only is your critical load insured of the most reliable and constant power available, but the user may now continuously track status of the supply components that keep the entire system operational. Production downtime can now be virtually eliminated by knowing exactly what patterns the supply utility power maintains and by knowing exactly the condition and life expectancy of the battery reserve.
Reference the block diagram for a simplified explanation of the system’s operation. The AC utility source is connected to the power and micro­electronics when the input switch is closed. The input line is filtered, power factor corrected and rectified for enhanced performance without disturbing other equipment that may share the same utility circuit. In SN units, an input isolation transformer is added to accept a wide range of input voltages for global applications. Output transformers, SNMP adapters and many other options are available.
The microprocessor controls an Inverter Generator that produces a low harmonic, AC sinewave for continuous power applications.
When the input AC utility line fails, the battery circuit within this system takes over to ensure continuous power. Only after properly rated power is returned, does the microprocessor reconnect the input source back into the system.
The microprocessor is directly tied to an external RS232 connector port. This allows the user to monitor and even set some of the operating parameters. With a simple link to a personal computer using the SNConfig software program, you can actually view, on your monitor, the event history of the power distribution system with the SN Series unit as the central hub. More sophisticated users may implement the optional SNMP package to accomplish full Network Power Management.
Page 4
THE CONTINUOUS POWER COMPANY
FIGURE 1: SN SERIES BLOCK DIAGRAM
BYPASS LINE
EMERGENCY
CUTOFF SWITCH
VOLTAGE
WINDOW
DETECTOR
COMMON
MODE
CHOKE
RECTIFIER
CHARGER
POWER
FACTOR
CORRECTOR
+ DC
RAILS
MICROPROCESSOR
CONTROLLER
AC
INVERTER
GENERATOR
LOAD
STANDBY BATTERY
COMMON
MODE
CHOKE
AUTO
VOLTAGE SELECTOR
SWITCH
UTILITY
INPUT
INPUT
TRANSFORMER
DB-9
CONTACTS
DB-9
RS232
PACKAGING
our UPS has been carefully packaged to withstand most abuse sustained during shipment. The packing material has been
Y
specifically designed to protect this system for normal handling, using most shipping carriers. If there is significant damage to the carton, or if there is any physical damage to this unit, report this to your carrier.
These units are encapsulated in a protective wrap that comes apart once the product is removed from
THE CONTINUOUS POWER COMPANY
the shipping carton. Save all packing material for future use.
Take extra precaution when removing or returning it to the box. Because this unit contains a battery, it can be quite heavy. Never attempt to unpackage the equipment unassisted.
The packaging also contains important information
!
on use and care as well as valuable warranty information. Read all materials before storing this literature with your other valuable product documents.
Page 6
PHYSICAL DESCRIPTION
THE CONTINUOUS POWER COMPANY
his section will point out and illustrate the various indicators, functions and controls of the SN Series UPS. Pictured is the front view
T
of the system, then followed by the rear view. The important attributes of the SN Series unit are numbered to assist you in locating them on your machine and also to fully explain its function and how it relates to system operation.
Numbers on the drawing will correspond to the operating component’s name at the bottom with a brief identification. In the next section, a complete explanation of all numbered items will be enhanced to ensure you have a full understanding of the operation of this system.
8 7
13
10
9
11
Visual indicators used on the front panel are long lasting, very efficient, light emitting diodes (LED). When operating the push-button switches, always hold the switch in for at least two seconds to insure function confirmation. This feature has been implemented into the system design to avoid inadvertent operation of any of the user-available functions.
The rear panel has been engineered with the user’s multiple applications in mind. In some models, two of the output receptacles have been rotated to allow attachment of a plug-in transformer without hanging over the back of the unit or interfering with another outlet. The outputs can be switched on or off.
6
12
14
2
4
5
1
3
AIR INTAKE, COOLING
15
LIFTING HANDLE
FIGURE 2: FRONT VIEW, SN1000
Page 7
Loading...
+ 14 hidden pages