Clarus Environmental WW4 Filter Sock User Manual

NOTICE TO INSTALLER: Instructions must remain with installation.
®
®
3649 Cane Run Road . Louisville, KY 40211-1961
877-244-9340 . Fax: 877-414-4316
www.clarusenvironmental.com
WW4 Filter Sock
WW4 FILTER SOCK INSTALLATION INSTRUCTIONS
SECTION: C2.20.140
CL0132
1011
Supersedes
New
APPLICATION
Use the Filter Sock in conjunction with the Clarus
INSTALLATION
1. Remove the primary lter assembly from the Clarus Environmental WW4 lter assembly.
2. Place the primary lter assembly down into the
Filter Sock (see Fig. 1).
3. Loop one end of the string around the lter holder post and tie the lter sock above the lower rim of the lter holder (see Fig. 2 and Fig. 3).
4. Press excess Filter Sock in between lters (see
Fig. 4).
5. Place the primary lter assembly back in the
Clarus Environmental WW4 housing.
6. Recommended peak ow through the lter is 1500 GPD. Multiple WW4 lters may be
manifolded together for installations requiring a
greater ow rate (see Fig. 6).
Fig. 2
Fig. 1
All Clarus Environmental products must be installed and maintained in accordance with all applicable codes. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
© Copyright 2011. All rights reserved.
Fig. 3
Fig. 4
Limited Warranty
Manufacturer warrants, to the purchaser and subsequent owner during the warranty period, every new product to be free from defects in material and workmanship under normal use and service, when properly used and maintained, for a period of one year from date of purchase by the end user, or 18 months
from date of original manufacture of the product, whichever comes rst. Parts
that fail within the warranty period, one year from date of purchase by the end user, or 18 months from the date of original manufacture of the product,
whichever comes rst, that inspections determine to be defective in material or
workmanship, will be repaired, replaced or remanufactured at manufacturer's option, provided however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior approval of manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has not been installed, operated or maintained in accordance with manufacturer's installation instructions; that has been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels or feminine sanitary
Fig. 5
PRIMARY FILTER
PULL ROD (24")
6"
CLARUS 24" DIA. SEPTIC TANK RISER CAST IN PLACE
SECONDARY FILTER PULL ROD (18")
SECONDARY FILTER
OUTLET 4" DIA. PVC PIPE, SCH 40 OR SDR35(SUPPLIED BY OTHERS)
products, etc. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products.
Contact manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211, Attention: Customer Service Department to obtain any needed repair or replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specic legal rights and you may also have other rights
which vary from state to state.
RISER OFFSET 5"
30" RISER
REQUIRED
OUTLET
SDR35 PVC TEE
Fig. 6
26 1/4"
25 5/32"
LIQUID PENETRATION PIPE
4" DIA PVC PIPE
SCH 40 OR SDR 35
(SUPPLIED BY OTHERS)
21 7/32"
11"
FILTER CONTAINER
PRIMARY FILTER ASSEMBLY
LEG BOSSES ACCEPT EITHER 1 1/4" OR 1 1/2" SCH 40 PVC PIPE
SEPTIC TANK
PVC "LEGS" (SUPPLIED BY OTHERS)
SERVICING
A routine maintenance schedule must be set up for each commercial application. Each application will vary depending on the amount and type of waste generated by the application. During the first two months of filter installation, the filter should be checked every two weeks.
To clean, withdraw the primary lter (long handle) with the Filter
Sock attached and rinse back into the septic tank and replace. Next,
remove the secondary lter (1/16" protection short handle), rinse
and replace.
“WW4” FILTER
OUTLET
SDR35 PVC TEE
SK2318A SK2318B
“WW4” FILTER
SCH40 PVC TEE
SDR35 PVC TEE
Cleaning the Filter Sock can be performed by business personnel or
a service company. If a service company is used, the primary lter
with Filter Sock should be placed in a large plastic bag for pickup
by the service company. As an alternative, landll the dirty sock and
replace it following the instructions on page 1 of this sheet. A clean
primary lter assembly with Filter Sock should be placed back into the WW4 housing. Remove the secondary lter and clean off. An extra primary lter assembly with Filter Sock should be kept on hand
by the business and service company. Depending on the amount of waste generated by the application, service intervals may be as short as a few days.
© Copyright 2011. All rights reserved.