NOTICE TO INSTALLER: Instructions must remain with installation.
®
®
3649 Cane Run Road . Louisville, KY 40211-1961
877-244-9340 . Fax: 877-414-4316
www.clarusenvironmental.com
Variable Level Control Switch
INSTALLATION INSTRUCTIONS
SECTION: C6.00.033
CL0114
1111
Supersedes
New
always disconnect power supply before handling or making adjustments to the variable control switch.
All installation of controls, protection devices and wiring should be done by a qualied
licensed electrician. All electrical and safety codes should be followed in addition to the most recent National Electrical Code and the Occupational Safety and Health Act (OSHA).
1. Determine your “on” level. (See illustration above) For pump down (NORMALLY OPEN) application: The variable level
control switch closes (turns on) when the oat tips a few degrees above the horizontal position and opens(turns off) when the oat drops a few degrees below the horizontal position. This mode is regularly used on pump applications.
For normally closed applications only: The variable level control switch closes (turns on) when the oat drops a
few degrees below the horizontal position and opens (turns off) when the oat tips a few degrees above the horizontal position. This mode is used to maintain a specic uid level in container when pumping from another source. (i.e. stock watering tank)
2. If cable weights are not being used, strap variable level control switch to discharge pipe or similar mounting at determined on-off level. (See sketch #1) NOTE: Do not install cord under hose clamp. NOTE: Be sure oat is positioned so that it will not be restricted in its movement by any item in the pit. The strap clamp should be a minimum of 3” from any top restriction (pit cover) or 9” from any bottom restriction (oor, pump, etc.).
3. If cable weights are used, adjust tether as shown in sketch. (See sketch #2)
NOTICE: Do not adjust “OFF” level below discharge on pump. Use Control Switch in panel controlled pump applications only.
To avoid electrical shock
CLAMP DETAIL
(Tether length non-adjustable)
SK1301H
SKETCH #1
CABLE WEIGHT (See Sketch #2)
1. Lay cable in weight channel.
2. Align clip with weight groove and slide towards cable.
3. Snap clip snugly up to cable, manually moving clip to the tightest possible position.
4. Wire cable leads directly into control device.
SKETCH #2
5. Suspend unit at desired activation level.
All Clarus Environmental products must be installed and maintained in accordance with all applicable codes. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.