Clarus Environmental Spider Valve User Manual

NOTICE TO INSTALLER: Instructions must remain with installation.
®
®
3649 Cane Run Road Louisville, KY 40211-1961
800-928-7867 Fax: 502-774-3624
www.clarusenvironmental.com
SECTION: C4.00.013
CL0078
0813
Supersedes
0112
FIGURE 1
WIRING CONDUIT
SEPTIC TANK
ALARM
Spider Valve
®
INSTALLATION INSTRUCTIONS
ALL WORK IN ACCORDANCE WITH NEC AND ANY OTHER
STATE OR LOCAL CODES
CLARUS STEP SYSTEM
24 OR 30 INCH ACCESS RISER & LID
FILTERED EFFLUENT
SPIDER VALV E MANIFOLD
FIGURE 1
TO OTHER TRENCHES
TYPICAL GRAVITY TRENCH
SK2322
PLACE WASHER INSIDE UNIONS DURING
FIELD ASSEMBLY
Installation Steps
1. Spider Valve® assembly must be
FIGURE 2
1/2" FLEX PIPE
installed at the high point of the system
such that the efuent will gravity drain
from the valve to the disposal trenches. Consult site plan and Figure 1.
2. At least 3' of distal pressure should be maintained on the manifold to ensure
1/2 X 1 1/4
RED BUSHING
DETAIL "A"
DETAIL "A"
2" MANIFOLD
proper efuent splitting.
TO DISTRIBUTION
NOTE: For sizing help please consult Clarus Environmental at 1-800-928-7867 or use the Spider Valve® Orice Sizing Tool to help design your onsite system at www.clarusenvironmental.com
FILL TO NEAR WITH GRAVEL
TOP OF MANIFOLD
2" GRAVEL BASE
Distal Pressure Flow (GPM) per Orice
Feet* psi 5/32" 3/16" 7/32" 1/4" 9/32" 5/16" 11/32" 3/8"
3 1.30 0.52 0.75 1.03 1.34 1.70 2.09 2.53 3.01
4 1.73 0.60 0.87 1.18 1.55 1.96 2.42 2.92 3.48
5 2.16 0.68 0.97 1.32 1.73 2.19 2.70 3.27 3.89
6 2.60 0.74 1.07 1.45 1.89 2.40 2.96 3.58 4.26
* The Distal Pressure selected will need to be added to the friction head and static head for the TDH.
© Copyright 2013. All rights reserved.
TRENCH
SK2323
Installation Steps, continued
3. For distribution systems with unequal length disposal trench lines, use the chart provided to determine the
correct ow rate for the diameter hole that must be eld drilled in the ow control washer. Install washers
into the unions as shown in Figure 2.
4. For distribution systems with equal length disposal trenches then drill 1/4" diameter holes (or larger) in all washers.
5. The manifold should be installed in a 24" or 30" diameter access riser with lid.
6. Bed manifold area with 2" of pea gravel. Manifold should be installed level.
7. The incoming line should be pressurized with at least 3' of distal pressure. The manifold should be connected to the pump line with a 2" union PVC pipe connection.
8. Outlet pipes contain 3' of exible PVC pipe with a 1-1/4" diameter connection. Run 1-1/4" or larger pipe
away and downgrade from manifold to individual trenches (check local codes).
9. Check that all connections are glued appropriately and watertight. Backll around manifold with pea gravel
until 2" pipe is almost buried. This will ensure the manifold does not move and stays close to level.
10. Place access riser and lid around manifold and nish backlling. Landscape as desired.
Maintenance Instructions
The Spider Valve should be inspected and maintained as needed during routine maintenance inspections of the system. Please follow the steps below to properly inspect and maintain the Spider Valve.
1. Please wear appropriate safety apparel and equipment when maintaining any wastewater component or system.
2. Remove the riser lid to access the Spider Valve.
3. Locate the 1/2” PVC union connections (see gure 2) and unscrew them one at a time to inspect the ow control washer orices for debris or obstructions. NOTE: It is important to inspect one union and ow control washer at a time so that ow control washers with different orice diameters are not mistakenly
installed within an incorrect union.
4. If the orice is obstructed, remove the ow control washer and use a nylon blush to clean it with water.
5. Reinstall the ow control washer within the correct union and reassemble.
6. Repeat steps 3-5 with each union until all have been inspected and cleaned as necessary.
All Clarus Environmental products must be installed and maintained in accordance with all applicable codes. Product information presented here reflects conditions at time of publication. Consult factory regarding
discrepancies or inconsistencies.
Your Peace of Mind is Our Top Priority
3649 Cane Run Rd. • Louisville, KY 40211-1961 • (800) 928-7867 • FAX: (502) 774-3624
www.clarusenvironmental.com
© Copyright 2013. All rights reserved.
®
Loading...