Clarson CS60 Operating And Installation Instructions

Page 1
PUBLIC III
CS60 Wireless Headset System
Operating and Installation
Instructions
Notes:
Zeppelinstr. 4 78083 Dauchingen Postfach 11 63 78080 Dauchingen
Tel.: +49 7720 9956-0
Fax: +49 7720 9956-22
Email: clarson@clarson.de
Internet: http://www.clarson.de
Technical modifications reserved 04/2011
Page 2
2
7
Notes
Central Unit
Ref. 40.054.311
RJ 45 8-olig
RJ 45
8-pin
RJ 45
8-pin
Microphone Loudspeaker Unit
Ref. 40.054.301 - bottom side
Standard Connection of the CS60 Headset System
to the microphone loudspeaker unit PUBLIC III
RJ 10
4-pin
RJ 45
8-pin
RJ 10
8-pin
Ref. 40.054.327 patch cable, 3 m
with RJ45 connector (8/8-pin), central unit <—> microphone loudspeaker unit
Ref. 40.054.376 patch cable, 3 m with RJ10 connector (4/4-pin), microphone loudspeaker unit <—> CS60 base sta­tion
2
Pos. B
RJ 10
4-pin
RJ45 8-pin
RJ 10
4-pin
Page 3
+
-

To log on to one or several headsets at the CS60 Base Station
If one or more headsets are required to operate from one CS60 base station, they need to be paired as follows:
1. Insert the headset into the base station´s charging unit
2. Push and hold the volume buttons +
and - of the base station for a min. of 5 sec. The power supply indicator flashes.
3. Push and hold the headset mute button
for a min. of 5 sec.
The online indicator illuminates.
4. Log on has been successful if the power supply indicator illuminates and the online indicator turns off.
5. This procedure has to be executed within 2 min., otherwise the headset returns to the initial state and the procedure needs to be repeated.
Operating Manual
1. CS60 Base Station settings:
Slide switch
(speech volume) to B
Configuration dial
to 1
IntelliStand switch
to I
Slide switch (listen volume) to 2
2. Connect the CS60 base station socket with the headset interface
of the PUBLIC III microphone loudspeaker unit, or directly with the
PUBLIC III Headset socket of the central unit.
3. Connect the power supply unit to the CS60 base station socket .
4. Turn on the PUBLIC III microphone loudspeaker unit (button ).
Push the CS60 headset speech button . The LED above the microphone loudspeaker unit push button flashes, the headset is activated.
5. Return to standard operating mode:
- Push the CS60 headset speech button .
- Turn the PUBLIC III microphone loudspeaker unit push button off and on again.
6. Please refer for all other functions to the PUBLIC III operating and installation instructions and the CS60 manufacturer´s instructions.
4
Pos. 1
Base Station
Headset
Base Station
- bottom side -
12
3
22
16
4
5
1
16
6
Pos. 2
Pos. I = OFF
Pos. B
1
7
8
10
7 8
20
20
10
23
23
2
5
12
10
13
25
20
14
16
24
23
15
22
21
18
Slide switch on B (speech volume) Slide switch on 2 (listen volume)
Speech volume + Speech volume -
IntelliStand switch in Pos. I = OFF Configuration dial in Pos. 1
AC power supply unit AC power supply port
Cable port to PUBLIC III central unit
40.054.311 resp. to microphone loud­speaker unit 40.054.301 (page 2)
Headset charging station Base station charge contacts
Charge indicator Talk indicator Power supply indicator Microphone
Speaker Speech button
Listen volume adjustments + / ­Headset mute switch Online indicator
Headset charge contacts Battery cover
19
1 2
3 4
5 6 7 8
Page 4
3
Ref. 40.030.004
Ref. 40.030.005
Neckband with fittings
Ref. 40.030.013
Headset with pre-installed battery, headband and ear-loop set (3 sizes)
Replacement battery
Ref. 40.030.008
Headset with base station headband and ear-loop set (3 sizes)
Charging station
Ref. 40.030.006
6
Power supply unit
Ref. 40.030.014
Headband with leather ear cushion and spare foam cushion
Ref. 40.030.009
Ear-loop set
(3 sizes with flexible fixing device)
Ref. 40.030.015
Components of the CS60 Wireless Headset System
3
Central Unit
Ref. 40.054.311
Optional Connection of the CS60 Headset-Systems
to the Central Unit PUBLIC III
Pos. B
RJ 10
4-polig
RJ 45
8-polig
RJ 45
8-polig
Microphone Loudspeaker Unit Ref. 40.054.301 - bottom side
CS60 Basis-Station
- Unterseite -
RJ 45
8-polig
RJ 10
4-polig
Ref. 40.054.378 patch cable, 3 m with RJ45/RJ10 connector (8/4-pin), central unit <—> CS60 base station
Attention: cable must be ordered separately!!!
RJ 45
8-polig
3
Pos. B
RJ 10 4-pin
RJ 45
8-pin
RJ 45 8-pin
CS60 Base Station
- bottom side -
RJ 45
8-pin
RJ 10
4-pin
RJ 45 8-pin
Loading...