Operating Guidelines
RA40
ATTENTION! Do not use the machine before you have read and understood the Instructions for Use Manual.
™
External battery charger
1a. Unplug the battery charger cord.
Reconnect it to the machine.
Onboard battery charger
1b. Disconnect the battery charger cord
from the electrical outlet.
2. Fill the tank with clean water. The
water temperature must not exceed
40° C.
Make sure the solution valve under
the machine is open.
3. For machine equipped with Chemical
Mixing system: Mount the tank with
a detergent suitable for cleaning
machines (highly concentrated and
low foaming detergent)
4. Install the squeegee and fasten it
with the knob.
5. Place the brush or the pad-holder
under the deck. Use the appropriate
brush to clean the floor.
6. Insert and rotate the operator key,
then start the machine by pressing
the One-Touch button. To engage
the brush, slightly press the pedal
speed and then release it.
At the end of use
7. Push the drive pedal to start cleaning.
Adjust the speed by applying
pressure to the drive pedal.
For the reverse mode press the
green button.
8. To change the solution flow level
push the solution button and
change the flow level according to
desired cleaning performance and
application.
9. If necessary press the vacuum button
for stop/start vacuuming.
10. Machines with Chemical Mixing
System: Always turn off the detergent
2 minutes before finishing by pressing
the detergent button to rinse out
detergent from the system and brush
before handling and cleaning.
11. Empty the recovery tank with the
hose. Then empty the solution tank
with the transparent hose.
12. Empty the debris tray and clean/
wash the recovery tank inside.
13. Clean the filter:
A) Close the solu tion valve under
the machine.
B) Remove the transparent cover and the
gasket, then remove and clean the
filter inside.
C) Reassemble the filter.
15. Remove to clean or change brush.
14. Take the squeegee off and remove
debris. Check and clean the
squeegee blades.
If the machine has been used until the Red light illuminates on the battery level indicator on the machine, a full recharge of the batteries (10-12 hours) will be required. Failure to
carry out this procedure may cause damage to the batteries. Charging the batteries after every use is recommended.
PLEASE ENSURE RED SOCKET IS LEFT DISCONNECTED AFTER RECHARGE IF THE MACHINE IS NOT TO BE USED ON A DAILY BASIS.
9435 Winnetka Avenue North • Brooklyn Park, MN 55445
Phone: 800.253.0367 • Fax: 800.825.2753
15. Clean the machine using a damp
cloth and when needed use a
neutral cleaning product.
16. Charge the batteries: Connect
the battery charger cord to the
electrical outlet.
17. Park the machine keeping the
recovery tank cover open and hang
the squeegee.
240 Superior Boulevard • Mississauga, Ontario, Canada L5T 2L2
Phone: 800.668.8400 • Fa x: 8 0 0.26 3 . 5111

Troubleshooting
RA40
ATTENTION! Do not use the machine before you have read and understood the Instructions for Use Manual.
The machine
doesn’t work
™
as it should?
1. Check if the power cord is correctly
connected and check if the battery
is charged.
2. Restart the machine without
pressing the drive pedal.
3. Check floor inclination is not
exceeding specifications.
4. Check if the electromagnetic brake
is locking.
The suction
doesn’t work
as it should?
1. Check if the suction hose is
correctly installed and cleaned.
2. Open the recovery tank and check
to see if the debris tray and float
are clean and working.
3. Check if squeegee blades are
damaged or dirty.
4. Check to see if the lid gasket is in
good and working condition and
sealing when the lid is closed.
The machine
doesn’t clean
as it should?
1. Check if you have the right
detergent and water settings.
2. Check if the solution valve is open. 3. Check to see if the solution filter
is clean.
4. Check to make sure the Chemical
Mixing System is clean. Eventually
purge the system.
The brush
doesn’t work
as it should?
1. Check if there’s a brush motor
overload “WARNING ALARM F2”
on the display.
2. Check if the brush is correctly
installed and not worn out or
if there are external materials
3. Check if the green switch Led of
the One-Touch button is flashing.
Wait until the light is steady.
9435 Winnetka Avenue North • Brooklyn Park, MN 55445
Phone: 800.253.0367 • Fax: 800.825.2753
240 Superior Boulevard • Mississauga, Ontario, Canada L5T 2L2
Phone: 800.668.8400 • Fa x: 8 0 0.26 3 . 5111
preventing brush rotation.