Clarke Power IG2200 Operation & Maintenance Instructions Manual

Page 1
2.2KW INVERTER GENERATOR
MODEL NO: IG2200
PART NO: 8877055
OPERATION & MAINTENANCE
INSTRUCTIONS
LS1209
Page 2
Thank you for purchasing this CLARKE 2.2kW Inverter Generator
Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not effect your statutory rights.

ENVIRONMENTAL PROTECTION

One of the most damaging sources of pollution is oil. Do not throw away used engine oil in with your domestic trash or down drains and sinks. Place it in a leak proof container and dispose of it according to local regulations.
2
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 3

TABLE OF CONTENTS

INTRODUCTION .................................................................2
GUARANTEE .......................................................................2
ENVIRONMENTAL PROTECTION ........................................2
TABLE OF CONTENTS .........................................................3
GENERAL SAFETY RULES ...................................................4
Work area ........................................................................................ 4
Positioning the generator .............................................................. 4
Fire prevention ................................................................................ 4
Prevention of electric shock .......................................................... 5
Additional safety rules for generators .......................................... 5
SAFETY SYMBOLS ...............................................................6
GENERATOR OVERVIEW ....................................................7
UNPACKING AND ASSEMBLY ...........................................8
BEFORE USING THE GENERATOR ......................................8
Earth point ....................................................................................... 8
Checking the air filter ..................................................................... 9
Check the engine oil level ............................................................. 10
Check the fuel level ....................................................................... 11
USING YOUR GENERATOR ................................................12
Starting the engine ......................................................................... 12
Connecting electrical devices ..................................................... 14
Economy switch ............................................................................. 16
Indicator lights ................................................................................. 16
Shutting down the generator ........................................................ 17
MAINTENANCE ..................................................................18
Engine oil (every 20 hours of use) .................................................. 18
Air filter (every 50 hours of use) ...................................................... 19
Spark plug (every 50 hours of use) ................................................ 20
Fuel tank filter .................................................................................. 21
TROUBLESHOOTING ..........................................................22
PARTS AND SERVICING .....................................................22
SPECIFICATIONS ................................................................23
DECLARATION OF CONFORMITY .....................................24
NOTES ................................................................................26
3
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 4

GENERAL SAFETY RULES

1M (3ft)
1M (3ft)
WARNING: EXHAUST FUMES CAN BE EXTREMELY DANGEROUS IF INHALED

WORK AREA

Always use in a well ventilated area.
Always position the exhaust outlet away from people.
Read these safety instructions before using the equipment.
• Keep children away from the generator

POSITIONING THE GENERATOR

1.
Keep the generator at least 1 m (3 ft) from buildings or other equipment, overheat.
2. Place the generator on a solid, flat surface.
3. Make su free from any material that could burn or be damaged by heat.
4. Never move or tilt th
or the engine may
re the surrounding area is
e generator whilst it is switched on.

FIRE PREVENTION

1. Always switch the engine OFF when refuelling.
2. Always refuel in a well ventilate area.
3. Never refuel while smoking or in the vicinity of an open flame.
4. Never overfill the tank, fill to the level s
pecified (See “Check the
fuel level” on page 11.).
5. Never smoke whilst refuelling and avoid smoking or using a naked flame near the generator.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
d
4
Page 5
6. Never start the engine if there is spilled fuel. Any spillage must be wiped clean and the generator allowed to dry before attempting to start the engine.

PREVENTION OF ELECTRIC SHOCK

1. Never use the generator in wet conditions unless it is well protected/ covered. Under these conditions, adequate ventilation MUST be provided
2. Never operate the generator with wet hands
3. Never use water or any other liquids to clean the generator.
4. Make sure you ground (earth) the generator
.

ADDITIONAL SAFETY RULES FOR GENERATORS

1. Always make sure the applied load does not exceed the generator rating. Overloading the generator is dangerous and could cause serious damage.
2.
Always
carrying out any maintenance.
3. Always allow the generator to reach operating speed before connecting a load.
4.
Never allow the generator to run out of fuel when a load is connected.
5. Never transport the generator with fuel in the tank.
6. Never connect the generator to commercial or residential power supply; e.g. ring main.
7. Never allow the generator air vents to become blocked.
disconnect the generator when
a
5
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 6

SAFETY SYMBOLS

Caution - The user should be aware of a general hazard
Dangerous Voltage
Flammable
Hot Surface - Do not touch
Poisonous fumes - Do not use the generator in an enclosed space.
Read Instruction manual before use.
6
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 7

GENERATOR OVERVIEW

NO DESCRIPTION NO DESCRIPTION
1 Air Vent Knob 10 Earthing Point
2 Fuel Cap 11 Economy Control Switch
3 Fuel Valve Knob 12 AC Sockets
4 Starting Handle 13 DC Socket
5 Left Side Maintenance Cover 14 DC Circuit Breaker
6 Top Maintenance Cover 15 Overload Indicator
7 Muffler 16 Output Indicator
8 Choke 17 Oil Alarm Indicator
9 Engine ON/OFF Switch 18 Primer Bulb
7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 8

UNPACKING AND ASSEMBLY

Unpack your Generator and check the following items are present. Should there be any missing or damaged during transit contact your Clarke dealer immediately.
• 1 x Inverter Generator
• 1 x Spark Plug Box Spanner
• 1 x Screwdriver/Tommy Bar
• 1 x Container with Spout for Oil Filling
• 1 x Operating & Instruction Manual
• 1 x 12V Battery Connector Lead
• 1 x Oil Drain Tube

BEFORE USING THE GENERATOR

IMPORTANT: Generators should ALWAYS be earthed. Make sure you ground (earth) the generator.
ore using your generator check that:
Bef
• The generator is in good condition and free from any damage.
• The generator is clean and free from fuel or oil spillage.
• The generator is correctly located for use (See page 4).
• There is no leakage.
NOTE: To avoid accidental spillage of fuel, always use a funnel to fill the
fuel tank. If fuel is spilled it must be removed from the unit before attempting to start the engine.

EARTH POINT

Always connect the generator to an earth point. The earth terminal is shown on the right.
8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 9

CHECKING THE AIR FILTER

1. Remove the left side maintenance panel.
Remove the three air filter cover
2. screws shown on the right.
3. Slide out the air filter cover.
4. Remove the air filter element.
5. If the air filter is damaged contact Clarke spare pa
rts department for
a replacement.
• If the filter is dirty, wash it in a
solution of
warm water and mild detergent and rinse thoroughly. Leave the filter to dry completely, once it is dry immerse the filter in clean engine oil and sqeeze the filter to remove excess oil.
WARNING: DO NOT USE FLAMMABLE SOLVENTS OR PETROL TO CLEAN THE AIR FILTER.
6. Replace the filter into its original position and rep
lace and secure the air
filter cover then Replace the left side maintenance panel.
9
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 10

CHECK THE ENGINE OIL LEVEL

Max Level
Min. Level
WARNING: YOUR GENERATOR MAY NOT BE SUPPLIED WITH OIL, ALWAYS ENSURE THAT THERE IS SUFFICIENT OIL BEFORE USE.
WARNING: TO CARRY OUT THIS CHECK, THE ENGINE MUST BE OFF.
NOTE: Place the generator on a level surface and check the oil level as
follows.
1. Remove the maintenance panel shown on the right.
Turn the oil filler cap anti-
2. clockwise and remove from the oil reservoir, wipe the dipstick with a clean cloth.
3. Insert the dipstick back into the oil filler tube and then remove it again.
4.
If the oil is below the Min. level on the dipstick, Fill the oil reservoir with fresh oil.
• Do not fill above the max level
mark (0.45 litre
s)
• We recommend the use of
SAE30 oil in this generator.
• Do not tilt the generator when
adding engine oil. This could result in overfilling and damage to the engine.
5. Replace the oil filler cap.
6. Replace the left side maintenance panel.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
10
Page 11

CHECK THE FUEL LEVEL

Fuel filler cap
WARNING: MAKE SURE THERE IS FUEL IN THE TANK WHEN USING THE GENERATOR. RUNNING OUT OF FUEL OR STOPPING THE ENGINE SUDDENLY WITH A LOAD CONNECTED COULD CAUSE SERIOUS DAMAGE.
1.
To check the fuel level, open the fuel filler cap.
2. Slowly add fuel to the fuel tank (maximum 7L)
• Do not overfill the fuel tank.
3. Replace the fuel filler cap secur
ely.
WARNING: FUEL IS HIGHLY FLAMMABLE AND POISONOUS.
WARNING: SEE “GENERAL SAFETY RULES” ON PAGE 4 AND READ THEM CAREFULLY BEFORE REFUELING.
WARNING: DO NOT FILL ABOVE THE TOP OF THE FUEL FILTER OR IT MAY OVERFLOW WHEN THE FUEL HEATS UP AND EXPANDS.
WARNING: WIPE UP ANY SPILLED FUEL IMMEDIATELY.
WARNING: AFTER REFUELING, MAKE SURE THE FUEL FILLER CAP IS TIGHTENED SECURELY.
RECOMMENDED FUEL
Your generator has been designed to use regular unleaded petrol with a octane number of 86 or higher.
11
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 12

USING YOUR GENERATOR

Air vent knob

STARTING THE ENGINE

1. Remove all connections from the AC sockets.
2.
Hold the fuel tank cap so that it will not move, and turn the air vent knob to the ON position.
3. Turn fuel valve to the ON position (pointing downwards).
Set the engine switch to ‘ON’.
4.
5. Set the choke to the required position.
• If the engine is cold, move the
choke to the left.
• If the generator is warm, move
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
the choke to the right.
12
Page 13
6. If this is the first time you are using the generator or if the generator had run out of fuel the last time you used it, pump the primer bulb 10 times to introduce fuel into the carburetter.
Hold the generator handle firmly
7. and pull the starting handle lightly until you start to feel resistance and then pull up sharply to start the engine.
NOTE: You may have to do this
more than once.
.
WARNING: ONCE THE GENERATOR HAS STARTED, RELEASE THE STARTING HANDLE SLOWLY TO AVOID INJURY/DAMAGE AS IT WHIPS BACK.
NOTE: When you first start the generator, the overload indicator may light
up for a few seconds, this is normal. If the overload indicator is still lit after 5 seconds, stop the engine and contact your Clarke dealer.
Once the engine has warmed up,
8. move the choke to the right.
13
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 14

CONNECTING ELECTRICAL DEVICES

The generator can supply both 230V AC and 12V DC
AC POWER
Start the engine. See page 12.
1.
2. Make sure the appliance is turned off before conn generator.
3. Connect the appliance to the generator.
CAUTION: MAKE SURE THAT THE APPLIANCE BEING CONNECTED IS IN GOOD WORKING ORDER, IF IT BEGINS TO ACT ABNORMALLY OR STOPS SUDDENLY, DISCONNECT IT FROM THE GENERATOR
CAUTION: MAKE SURE THE APPLIANCE DOES NOT EXCEED THE MAXIMUM RATED LOAD FOR THE GENERATOR.
CAUTION: ANY DEVICE WHICH CONTAINS AN INDUCTIVE LOAD E.G. DEVICES THAT CONTAIN A MOTOR MAY REQUIRE MORE CURRENT ON STARTUP.
ecting it to the
14
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 15
DC POWER
For charging car batteries only
CAUTION: MAKE CONNECTIONS TO THE BATTERY AFTER STARTING THE GENERATOR.
1. Set the economy control switch to ‘OFF’.
2. Start the generator.
WARNING: TO PREVENT THE POSSIBILITY OF CREATING A SPARK NEAR THE BATTERY, CONNECT THE BATTERY CHARGING LEAD TO THE BATTERY FIRST AND THEN INSERT THE BATTERY CHARGING LEAD INTO THE GENERATOR.
3. Connect the battery charging leads to the battery.
• Clamp the red wire to the
positive (+) terminal and the black wire to the negative (-) terminal of the battery. Do not reverse these positions.
4. Connect the battery charging leads to the generator.
WARNING: AFTER YOU HAVE CHARGED THE BATTERY, ALWAYS DISCONNECT THE NEGATIVE LEAD FIRST.
DC OVER LOAD PROTECTOR
If the DC overload protector activates, wait for a few minutes and then pr
ess the reset button shown on
the right.
15
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 16

ECONOMY SWITCH

When the economy control switch is turned on, the engine speed varies according to the load connected. This results in decreased fuel consumption and less noise.
When the economy control switch is turned off, the engine runs at the 5,000 r/min. regardless of whether there is a load connected or not.
CAUTION: THE ECONOMY CONTROL DOES NOT WORK EFFECTIVELY IF THE ELECTRICAL APPLIANCE REQUIRES ‘BURSTS’ OF POWER.
CAUTION: TURN THE ECONOMY CONTROL FEATURE OFF WHEN CONNECTING HIGH LOAD APPLIANCES OR WHEN CONNECTING TO THE DC OUTPUT.

INDICATOR LIGHTS

PILOT LIGHT
The pilot light (Green) will remain on during nor
OVERLOAD INDICATOR
The overload indicator (Red) will light up if there is an overload or a short circuit in the connected appliance.
If this happens, proceed as follows:
1. Turn off any connected electrical device
2. Reduce the total wattage of connected electric devices to within the rated output of the generator.
3. Check air inlet and around the control unit. If any blockages remove them.
mal operation.
and stop the engine.
s
are found,
4. After checking, restart the engine.
LOW OIL INDICATOR
The oil indicator will light up when the oil level is low. To add oil, follow the instructions on page 10
16
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 17

SHUTTING DOWN THE GENERATOR

Air vent knob
To stop the generator in an emergency simply set the engine switch to ‘OFF’.
NOTE: Turn off any electric devices.
NOTE:
Set the economy control switch to the ‘0’ (OFF) position.
1. Disconnect any electric devices.
2.
Turn the fuel valve knob to “OFF” (pointing left).
3.
Turn the air vent knob to the off position.
4. Set the engine switch to the “0” (OFF) position.
17
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 18

MAINTENANCE

Max Level
Min. Level

ENGINE OIL (EVERY 20 HOURS OF USE)

CAUTION: PROLONGED EXPOSURE TO USED ENGINE OIL IS DANGEROUS, ALWAYS WASH YOUR HANDS THOROUGHLY AFTER HANDLING USED ENGINE OIL.
1. Remove the maintenance panel shown on the right.
Turn the oil filler cap anti-
2. clockwise and remove from the oil tank.
Screw the oil drain tube into the oil
3. tank as shown.
4. Tilt the generator to allow the oil to drain out of the oil a suitable container.
NOTE: You may need assistance
with this step as the generator is heavy.
5.
Fill the oil reservoir with fresh oil.
• Do not fill above the max level
mark (0.45 litre
• We recommend the use of
SAE30 oil in this generator.
6. Replace the oil filler cap and m
nance panel.
ainte
reservoir into
s)
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
18
Page 19

AIR FILTER (EVERY 50 HOURS OF USE)

1. Remove the maintenance panel shown on the right.
Remove the three air filter cover
2. screws .
3. Pull out the air filter cover.
4. Remove the air filter element.
5. If the air filter is damaged contact Clarke spare pa
rts department for
a replacement.
• If the filter is dirty, wash it in a
solution of warm water and mild detergent and then rinse thoroughly.
• Leave the filter to dry completely, once it is dry immerse the filter in
clean engine oil and sqeeze the filter to remove excess oil.
WARNING: DO NOT USE FLAMMABLE SOLVENTS OR PETROL TO CLEAN THE AIR FILTER.
6. Replace the filter into its original position and replace and
secure the air
filter cover.
19
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 20

SPARK PLUG (EVERY 50 HOURS OF USE)

CAUTION: ALLOW THE ENGINE TO COOL BEFORE REMOVING THE SPARK PLUG.
1. Remove the top maintenance panel.
2. Remove the spark plug cap from the spark
ssemble the spark plug spanner
3. A as shown.
plug.
4. Use the spark plug spanner (supplied) to remove the spark plug.
5. Check for discoloration and use a wire
brush to remove any carbon
build up.
20
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 21
6. Check the spark plug gap (a) with
Fuel filler cap
Fuel filter
a feeler guage, it should be between 0.6 and 0.7 mm.
• Adjust if necessary.
7. Check the overall condition of the spark plug an
d replace if
damaged.
NOTE: Spark plugs are available
from Clarke Spare Parts department 020 8988 7400.
8. Reinstall the spark plug and replace the spark plug cap.

FUEL TANK FILTER

Just inside the fuel tank is a fuel filter, check this filter periodically and remove any contaminants which may have accumulated.
1.
Remove the fuel tank cap
2. Lift out the filter inside.
3.
Clean the filter with solvent. If damaged, replace.
4. Relace the filter and fuel tank cap.
21
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 22

TROUBLESHOOTING

For Parts & Servicing, please contact your nearest dealer, or
CLARKE International, on one of the following numbers.
PARTS & SERVICE TEL: 020 8988 7400
PARTS & SERVICE FAX: 020 8558 3622
or e-mail as follows:
PARTS: Parts@clarkeinternational.com
SERVICE: Service@clarkeinternational.com
PROBLEM CAUSE SOLUTION
The generator fails
tart
to s
The generator fails
ge
nerate
to electricity
The generator is
ficult to start
if
d
Engine switch is off Set the engine switch to ‘on’
Not enough oil in the generato
No fuel Add more fuel, See page 11
Spark plug not working correctly
The device you are trying to power is faulty
The overload indica
(DC supply only) The DC Ov activated
The air filter is dirty Clean the air filter. See page 19
r
tor is on Remove the appliance
erload protector has
.
Add more oil, See page 10
Change the spark plug, See page 20
Make sure the device you want to power is working properly
immediately, do not connect any appliance that requires more than
2.2 KVA.
Press the reset button. See page 16
If this does not solve your problem, please contact the Clarke service department. see below.

PARTS AND SERVICING

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
22
Page 23

SPECIFICATIONS

Engine Engine Model 152F
Type
Forced air cooled 4­stroke gasoline OHV
IG2200
Displacement (cm3)
Ignition type
Fuel tank capacity (L) 7
Maximum run time at full lo
Engine oil capacity (L) 0.45
Guaranteed sound power (L
Generator Rated Frequency (Hz) 50
Rated AC Voltage (V) 230
Rated Power (KW) 2
Max. Power (KW) 2.2
Rated DC Voltage (V) 12
Rated DC Current (A) 8.3
Dimensions Length (mm) 542
Width (mm) 288
Height (mm) 486
Unpacked Weight (kg) 26.6
ad (h) 6
WA dB) 94 dB
125
T.D .I
23
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 24

DECLARATION OF CONFORMITY

24
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 25

DECLARATION OF CONFORMITY

25
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 26

NOTES

26
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 27

NOTES

27
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com