This highly efficient centrifugal pump is designed for pumping clean water, or
water containing sand or solids in suspension, that is with a maximum of 5% solid
content, and a maximum 12mm in diameter.
Before using the pump, please read this instruction manual thoroughly and
carefully follow all directions given. This is for your own safety and for that of
others around you, and will also help you achieve long and trouble free
service from your pump.
GUARANTEE
• This product is guaranteed against faulty manufacture for a period
of 12 months. Please keep your receipt as proof of purchase.
• This guarantee is invalid if the product is found to have been abused
or tampered with in any way, or not used for the purpose for which it
was intended.
• Faulty goods should be returned to their place of purchase, no
product can be returned to us without prior permission.
• This guarantee does not effect your statutory rights.
SPECIFICATIONS
Motor ........................................................... 230V 50Hz 1ph
Motor Rating (Nominal) .............................. 1.29kW
Outlet Connection ...................................... 2” BSP Male
Head Max. ................................................... 15.3M
Part Number ................................................ 7230095
2
Page 3
PUMP FEATURES
The pump is of rugged and durable construction, designed for long lasting
continuous operation and its’ stainless steel body provides good anticorrosive
properties. The motor is provided with built in overload protection.
IDEALLY SUITED FOR
• Draining ponds, pools, cellars, drains, building excavations , etc.,
where water temperature does not exceed 40°C.
• Pool, Fish pond circulation
• Rain Water drainage
• Waterfall fountain
• Gardening spraying
• Sump pit
• Waste water drainage
• Emergency uses such as drawing water from tanks or rivers,
excavations, flooded underpasses etc.
NOTE: Whenever the pump is used to pump contaminated water, e.g. to
drain fish ponds, you must ALWAYS immerse the pump in clean
water and run it for a few minutes afterwards to ensure all
contaminants are removed.
NOT SUITABLE FOR
• Pumping salt water, aggressive or chemical substances.
• It MUST NOT be used for pumping hydrocarbons (petrol, diesel fuel,
oils, solvents etc).
• Pumping slurry, sludge, mud or heavily polluted water.
ENVIROMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in
relation to the treatment, recycling & recovery and environmentally
sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal
facility.
3
Page 4
SAFETY PRECAUTIONS
1. This pump is designed to pump WATER ONLY. Never use for pumping
flammable liquids or chemicals of any kind.
2. NEVER allow the pump to run dry.
3. An approved Residual Current Device (RCD) MUST be used when pumping
from ponds or swimming pools.
4. Your submersible pump may ONLY be used for pumping water from a
swimming pool when there is no person or animal in
the pool.
5. ALWAYS disconnect the pump from the electrical
supply before placing into, or removing from
water, and before any cleaning or
maintenance.
6. When raising or lowering the pump, ALWAYS
use a rope or chain attached to the handle.
NEVER lift or carry the pump by the mains
cable or the float switch cable.
7. DO NOT run the pump with the body
exposed for longer than 10 minutes.
8. DO NOT install the pump on sand, silt, mud etc., or
ground which is likely to shift.
9. If pumping water which is liable to freeze, the pump
MUST be run continuously, otherwise the pump must be removed from the
water and stored in a frost free location.
10. If the pump is to be used where there may be silt or mud (e.g., garden
ponds), ALWAYS keep the pump clear of any sediment by standing it on a
platform or bricks or suspending from a rope or chain attached to the
handle.
11. DO NOT use for permanent installation in pumping clean or pure water,
(particularly drinking water), as there is the remote risk of contamination,
should there be a leak in the seal device.
12. If the mains cable becomes damaged, it MUST be replaced - NOT
repaired. (See Electrical Installation).
13. If used in a confined space - in a shaft or sump etc., ENSURE the float has
sufficient room to operate correctly (see Installation on page 8).
WARNING: FAILURE TO COMPLY WITH THESE SAFETY PRECAUTIONS
COULD BE EXTREMELY HAZARDOUS, NOT ONLY CAUSING A RISK TO
PERSONAL SAFETY BUT ALSO DAMAGE TO THE PUMP, WHICH COULD
INVALIDATE YOUR GUARANTEE.
4
Page 5
ELECTRICAL CONNECTIONS
The mains lead should be connected to a standard 230Volt (50Hz) electrical
supply through an approved 13Amp BS 1363 plug or a suitably fused isolator
switch. We recommend that the pump be connected via a Residual Current
Device (RCD).
IMPORTANT: If used for draining swimming pools or ponds, it is mandatory that
the pump be fitted with a Residual Current Device (RCD), with a rated residual
operating current of no greater 30mA.
If the pump is to be connected to an outdoor electrical supply, make sure that
both the plug and the socket are of a BS approved waterproof design.
In the event that the pump is hard wired into the electrical system, it must be
carried out in accordance with IEE regulations.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
Green & Yellow-Earth
Blue-Neutral
Brown-Live
As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug proceed as follows:
Connect GREEN & YELLOW cord to plug terminal marked with a letter “E” or
Earth symbol “ ” or coloured GREEN or GREEN & YELLOW.
Connect BROWN cord to terminal marked with a letter “L” or coloured RED
Connect BLUE cord to terminal marked with a letter “N” or coloured BLACK
FUSE RATING
The fuse in the plug for this appliance must be rated at 13 amps.
If this appliance is fitted with a plug which is moulded onto the electric cable (i.e.
non-rewirable) please note:
1. The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.
2. Never use the plug without the fuse cover fitted.
3. Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).
4. Replacement fuse covers can be obtained from your local dealer or most
electrical outlets
5. The fuse in the plug must be replaced with one of the same rating (13 amps)
and this replacement must be ASTA approved to BS1362.
5
Page 6
PARTS IDENTIFICATION
Handle
Outlet Connector
Pump
Float Switch
Base
6
Page 7
PREPARATION
CONNECT THE DELIVERY HOSE
WARNING: DISCONNECT THE PUMP FROM THE MAINS POWER SUPPLY
BEFORE CONNECTING THE DELIVERY HOSE
The pumps outlet connecter is provided with a 2” BSP Male thread, for
connection to a suitable adapter (not provided). It is advisable to seal the
thread with PTFE, or similar tape, to ensure maximum performance from your
pump.
Where it is necessary for long horizontal stretches of delivery hose to be used,
the hose ID should be greater than that of the delivery outlet.
NOTE: When the pump is used in a permanent or semi-permanent
installation, a check valve MUST be fitted in the delivery pipe.
NOTE: Suitable hoses are available from your Clarke dealer.
LOCATING THE PUMP
1 Tie a rope to the lifting handle of the pump and lower the pump on a flat
surface in the area that you want to drain.
• If there is sediment in the operating area, the pump should be
placed on house bricks, or similar.
• Ensure the pump is positioned with adequate space so that the
movement of the float switch is not restricted.
NOTE: The symbol
MAXIMUM depth to which the pump may be submerged, in
metres.
• The pump should be well clear of silt, mud or any type of marine
growth.
• Take all necessary precautions as described on page 4 before
plugging in, and switching ON.
WARNING: NEVER CARRY THE PUMP USING THE MAINS POWER CABLE.
DAMAGE TO ELECTRICAL CABLES CAN BE DANGEROUS. ALWAYS USE THE
LIFTING HANDLE OR A ROPE ATTACHED TO THE LIFTING HANDLE WHEN
MOVING THE PUMP.
on the pumps’ Rating Plate, denotes the
7
Page 8
USING THE PUMP
CAUTION: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE
THE PUMP IF IT IS DAMAGED IN ANY WAY.
1 Connect the mains plug to a high sensitivity residual current device (RCD)
which has a tripping current of less then 30mA.
2 Switch the mains power supply on.
• The pump incorporates a float
switch, which automatically
switches the pump ON when
the water is above a
predetermined level.
3 The pump will begin to drain
water.
• As the water level falls, so will
the float switch, until it stops the
pump.
4 When the pumping is finished, disconnect the pump from the mains power
supply.
• The pump is fitted with a thermal cut out to protect the motor from
overheating. If the thermal cut out activates, the motor will stop and
automatically switch back on when it has cooled down sufficiently.
8
Page 9
CLEANING AND MAINTENANCE
WARNING: MAKE SURE THAT THE PUMP IS DISCONNECTED FROM THE
MAINS SUPPLY BEFORE CLEANING, OR PERFORMING ANY
MAINTENANCE.
• The pump should require no maintenance other than regular
cleaning. Its’ mechanical seal is lubricated in an oil chamber, and its’
bearings are ‘sealed for life’. If the pump starts to show signs of wear
or damage, contact your CLARKE dealer for advice.
• Do not use the pump if there is any damage to the mains supply
cable, or to the float switch or its cable.
• Check the pump installation regularly to ensure the base inlet is clear
of leaves or other debris.
• Do not attempt to repair the pump yourself, as you may damage the
seals and invalidate your guarantee. Repairs must be carried out by
a qualified pump engineer, your CLARKE dealer, or contact the
CLARKE Service Department on: 020 8988 7400.
If the pump becomes badly clogged, the stainless steel strainer may be
removed and cleaned by removing the three screws
DO NOT attempt to remove any other screws.
Backflush the pump chamber by directing a jet of clean water through the
outlet port.
FROM THE BASE ONLY.
WARNING: DO NOT ATTEMPT TO STRIP THE PUMP FURTHER AS THIS WILL
INVALIDATE THE GUARANTEE.
ANNUALLY OR EVERY 2000 WORKING HOURS (Whichever is sooner)
The sealing oil must be checked by a qualified pump engineer. Consult your Clarke
dealer, or Clarke International Service Department.
9
Page 10
TROUBLE SHOOTING
PROBLEMPROBABLE CAUSE
Pump will not start.Check to ensure power is switched on.
Check fuse (consult an electrician if in doubt).
If extension lead is fitted, check connections (consult an electrician if
in doubt).
Internal thermal cutout has not reset. Leave for 15 minutes and try
again.
The Impeller may be jammed. Disconnect from the mains supply,
remove the bottom strainer and remove any objects that may be
obstructing the impeller. Replace the strainer and try again.
Float switch may be jammed against side wall or prevented from
moving.
Water level too low - float switch in OFF position - Lift float to check
switch. If the pump still fails to start, consult your CLARKE dealer for
advice.
Pump will start but not
pump water.
Check to ensure strainer is not blocked - clean as necessary.
Discharge tube clogged or obstructed - clear as necessary.
The head may be too great, i.e. you are trying to lift the water too
great a distance for the pump to cope with. (See specifications
pages 2 ).
Impeller may be damaged - Consult your CLARKE dealer.
Pump will not stop.Float switch may be prevented from moving to the fully down
Pump stops running.Thermal overload has operated. If this condition persists, investigate
position.
Float switch may be faulty. Consult your CLARKE dealer for advice.
the cause. DO NOT attempt to pump anything other than clean
water.
Pump has run dry, or float switch has cut in.
A foreign object has jammed the impeller.
PARTS & SERVICE CONTACTS
For spare parts and service, please contact your nearest dealer,
or CLARKE International, on one of the following numbers.
PARTS & SERVICE TEL: 020 8988 7400
or e-mail as follows:
PARTS: Parts@clarkeinternational.com
SERVICE: Service@clarkeinternational.com
10
Page 11
11
Page 12
12
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.