Clarke IDH 50L, 6470611 User guide

Page 1
50L INDUSTRIAL DEHUMIDIFIER
MODEL NO: IDH50L
PART NO: 6470611
OPERATION & MAINTENANCE
INSTRUCTIONS
DL0422 Iss 1
Page 2
Thank you for purchasing this CLARKE 50 Litre Industrial Dehumidifier.
Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not effect your statutory rights.
ENVIRONMENTAL RECYCLING POLICY
Recycle unwanted materials instead of disposing of them as waste. All unwanted accessories and packaging should be sorted and taken to a recycling centre for disposal in a manner which is compatible with the environment.
By purchasing this product, the customer is taking on the obligation to deal with its safe disposal in accordance with the Waste Electrical and Electronic Equipment regulations (WEEE).
In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
R290 is a refrigerant that complies with EEC environmental standards; nonetheless, the refrigerant circuit on the machine should not be punctured. At the end of its working life, consign the dehumidifier unit to a special collection centre.
2
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 3
ELECTRICAL CONNECTIONS
Plug must be BS1363/A approved.
Always fit
Ensure that the outer sheath of
Neutral
(Blue)
Live
(Brown)
Earth
(Green and
a 13 Amp
the cable is firmly held by the clamp
fuse.
Yellow)
WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY.
Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz. Connecting it to any other power source may cause damage.
This product may be fitted with a non-rewireable plug. If it is necessary to change the fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or damaged, the plug must not be used until a suitable replacement is obtained.
If the plug has to be changed because it is not suitable for your socket, or due to damage, it should be cut off and a replacement fitted, following the wiring instructions shown below. The old plug must be disposed of safely, as insertion we would emphasise the electrical hazard.
We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD).
If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.
WARNING: THE 3 CORE WIRE IN THE MAINS LEAD IS COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: GREEN/YELLOW = EARTH, BLUE = NEUTRAL, BROWN = LIVE.
•The BLUE wire must be connected to the terminal marked N or coloured black.
•The BROWN wire must be connected to the terminal marked L or coloured red.
•The YELLOW AND GREEN wire must be connected to the terminal marked E
or or coloured green.
3
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 4
OVERVIEW
No. Description
1Handle
2 Control Panel
3 2 x Wheels
4 Continuous Drainage Pipe Outlet Hole
52 x Feet
6 5 Litre Internal Water Tank
7 Air Inlet and Filter
8 Air Filter Pull Tab
Contents List: 1 x 50L Dehumidifier, 2 x Wheels, 1 x Wheel Axle Rod (Inc: Nuts & Washers), 4 x Axle Fixing Screws, 1 x Drainage Pipe
4
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 5
SAFETY WARNINGS
WARNING: IF THE SUPPLY CABLE IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN ORDER TO AVOID A HAZARD.
1. Please read these instructions carefully and retain for future reference.
2. Position the mains cable so that it cannot be inadvertently pulled or pinched and where it does not cause a trip hazard.
3. This appliance is designed to dehumidify industrial environments and MUST NOT be used for other purposes.
4. If the appliance requires repair, ALWAYS contact your CLARKE dealer. ALWAYS insist on original spare parts. Repairs carried out by unauthorized persons may be dangerous and invalidate the guarantee.
5. Children SHOULD NOT play with the appliance. Cleaning and user maintenance SHOULD NOT be undertaken by children.
6. Before cleaning or maintenance operations, ALWAYS unplug the appliance from the power supply.
7. DO NOT move the appliance by pulling the power cable.
8. DO NOT install the appliance in rooms containing gas, oil or fuel.
9. DO NOT install near sources of heat.
10. DO NOT use the appliance on inclined surfaces.
11. Keep the appliance away from inflammable substances (alcohol etc) or pressurised containers (e.g. aerosol cans).
12. DO NOT rest heavy or hot objects on top of the appliance.
13. ALWAYS transport the appliance upright. Wait at least 1 hour after
transporting the appliance before using it to allow the refrigerant gasses to settle.
14. DO NOT use the appliance outdoors.
15. DO NOT obstruct the air inlet or outlet.
16. DO NOT use means to accelerate the defrosting process or to clean, other than those recommended in this manual.
17. DO NOT store in a room continuously operating ignition sources like open flames, operating gas appliance or electric heater.
18. DO NOT cover the dehumidifier when in use. Place at least 50cm (100cm from front) from walls, doors, windows or obstructions.
5
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 6
WARNING: DO NOT USE OR STORE THE DEHUMIDIFIER NEAR A HEAT SOURCE, AS THE UNIT CONTAINS PRESSURISED FLAMMABLE REFRIGERANT GAS (R290-HYDROCARBON PROPANE)
R290 REFRIGERANT GAS (HYDROCARBON PROPANE)
H220: Extremely Flammable Gas.
H280: Contains Gas Under Pressure, May Explode if Heated.
R290 refrigerant gas complies with UK & European environmental directives.
R290 has a low GWP (Global Warming Potential) of 3 and CO2 equivalent to 0.0006t.
The dehumidifier contains approximately 200g of R290 refrigerant gas. The refrigerant system MUST NOT be perforated or punctured.
DO NOT use or store in an unventilated space with an area smaller than
4m² per unit. The room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
• Refrigerant gas may be odourless.
DO NOT use the product and contact the retailer for advice if damage
has occurred to the unit which may have compromised the refrigerant system.
• Any repairs or maintenance must only be carried out on the unit by a
suitably qualified engineer. Before opening and servicing the unit, the authorized engineer must be in possession of a copy of the manufacturer's service manual and must follow the safety information contained within it to ensure all hazards are minimized.
6
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 7
SAFETY SYMBOLS
Read the manual and safety instructions before use
Indoor use only Warning: Risk of Fire,
TECHNICAL SPECIFICATION
Power Source AC 230V 50Hz
Do not cover when in use
Flammable Gas (R290)
Input Current @ Rated Load
Power
4.0A @ 30
900W @ 30
o
C RH 80%, 3.4A @ 27oC RH 60%
o
C RH 80%, 750W @ 27oC RH 60%
IP Rating IP22
Dehumidifying Extraction Rate
50 litres/day @ 30 30 litres/day @ 27
o
C RH 80%
o
C RH 60%
Max. Suction Pressure 1.0Mpa
Max. Discharge Pressure 2.5Mpa
Max. Air Flow Rate
Working Space
300m
50 - 120m
3
/h
3
Water Tank 7 litre tank with 5 litre capacity
Operating Temperature
o
C - 35oC
5
Refrigerant 200g of R290 (Hydrocarbon Propane)
Weight 31kg
Dimensions (DxWxH) Handle Down: 480mm x 450mm x 655mm
Handle Up: 480mm x 450mm x 900mm
7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 8
ASSEMBLY
HANDLE
1. Place the machine in the upright position, Lift the handle on the rear of the machine by 180 degrees to the upright position.
2. Secure the handle in position using the fixing screws provided.
WHEELS
1. Incline the machine body, as shown, and fix the wheel axle on the bottom of the machine body using the 4 screws.
2. Using the nuts and washers, fix the wheels to the axle rod.
3. Once the wheels have been installed, place the machine in the upright position.
NOTE: Once assembly is complete, leave the machine to stand for a
minimum of 1 hour, this is for the refrigeration gases to settle before use.
8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 9
OPERATION
CONTROL PANEL
No. Description No. Description
1Timer 7Subtract
2 Temperature 8 Add
3 Dehumidification 9 Full Water Tank
4 Humidity 10 Air Speed
5 Power 11 Defrosting
6Timer Set
Button Operation Instructions
On/Off (Button 5) Switches the machine On and Off
+ (Button 8) Adjusts different set values in different states:
1: Increases the humidity value set (RH 10% to 95%) 2: Increases the timing (Hours) set (00 to 24)
- (Button 7) Adjusts different set values in different states: 1: Decreases the humidity value set (RH 10% to 95%) 2: Decreases the timing (Hours) set (00 to 24)
Timer (Button 6) Short press the button to launch a cycle to Off.
Set On/Off timer and exit
9
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 10
WATER TANK & CONTINUOUS DRAINING
This machine has a 7 litre internal water tank. When the water tank is full, the machine will automatically shutdown at 5 litres and enter standby mode, on the LED display the ‘Full Water Tank’ will light up and an alarm will sound.
TO EMPTY THE TANK
1. Open the water tank door at the front of the machine.
2. Pull water tank out of the holding clips and empty.
3. Replace the water tank back in the holding clips and close the door.
NOTE: The water tank full alarm will
continually sound when the tank is removed and will not turn off until the tank is empty and correctly seated back in the machine.
PREPARATION FOR CONTINUOUS DRAINING
An external drainage pipe enables continuous dehumidifying without having to empty the water tank.
1. Extract the water tank from the machine and remove the plug from the water tank spout.
2. Locate the external drainage pipe and feed it through the drainage pipe outlet hole on the side of the machine.
3. Place the end of the pipe onto the water tank spout and replace the tank back in the machine.
4. Place the external end of the pipe into a suitable receptacle/ drain ensuring that the end of the pipe is below the level of the outlet in the unit body.
NOTE: If using a receptacle, make
sure it is large enough as the machine can produce up to 50 litres of water in a 24 hour period.
10
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 11
NOTE: The pipe has an internal diameter of 13mm and is 100cm long.
NOTE: DO NOT submerge the end of the pipe in water, as this may cause
water to be drawn back up into the machine.
TIMING AND ON/OFF FUNCTION
Setting the timer for both powering on and off will initiate the cycle timer mode.
SETTING OF TIMER - POWER ON
1. When the machine is powered off, press the “Timing” button.
2. The “Timing On” icon will flicker and the time set will flicker on the display screen.
3. Press the “+” or “-” buttons to adjust the timing. The dehumidifier will make a sound once the button is pressed. The time set will increase or decrease by “1”, holding the button for 2 seconds will continually increase or decrease the time.
4. Once the required time is set, non-action of the buttons for 10 seconds the dehumidifier will accept the new setting and the “Timing On” icon will flicker (Ranging from 0 to 24 hours, and 0 hours as default).
SETTING OF TIMER - POWER OFF
1. When the machine is powered on, press the “Timing” button.
2. The “Timing Off” icon will flicker and the time set will flicker on the display screen.
3. Press the “+” or “-” buttons to adjust the timing. The dehumidifier will make a sound once the button is pressed. The time set will increase or decrease by “1”, holding the button for 2 seconds will continually increase or decrease the time.
4. Once the required time is set, non-action of the buttons for 10 seconds the dehumidifier will accept the new setting and the “Timing Off” icon will flicker (Ranging from 0 to 24 hours, and 0 hours as default).
HUMIDITY CONTROL
• When the rooms humidity value is 3% lower than the set humidity on the
machine, the compressor will shut down, the fan will delay shut down for 3 minutes and then shut down; and when it is 3% higher than the humidity value set on the machine, both the fan and compressor will start to operate.
• When the humidity is set at the minimum value (10%), the machines
default will enter the continuous dehumidifying mode.
11
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 12
• When started, the compressor will start 3 seconds later and when it is
shut down, the fan will run for 3 seconds.
• If a fault of the humidity sensor occurs, the machine will turn to the
continuous dehumidifying mode.
• If a fault of the coil sensor occurs, the machine will turn to the timing
defrosting mode (See Defrosting Mode).
PROTECTION FUNCTION
• Once shut down, the compressor will take 3 minutes to restart. Quick
start is available for the first power-on.
Power off memory: For abrupt power outage or accidental unplugging,
the machine will automatically return to the operating state right before the ‘incident’, and continue at that state for the next power-on.
DEFROSTING MODE
Defrosting Mode
Automatic Defrosting
Timing Defrosting
Description
Sensor at Normal State 1: It enters this mode when the
compressor runs constantly for 30 minutes and the coil temperature is
o
tested to be < or = 1 2: In defrosting, the compressor stops running, the fan continues running and the defrost light is on.
In this mode, the machine will defrost for 8 minutes and then switch to standby mode.
C.
12
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 13
MAINTENANCE
WARNING: ALWAYS UNPLUG THE DEHUMIDIFIER BEFORE PERFORMING ANY CLEANING OR MAINTENANCE OPERATIONS.
CLEANING THE CABINET
• Use a soft damp cloth to clean the exterior.
• Never use harsh chemicals or abrasive cleaning agents as these may
damage the casing finish.
• Clean the water tank and its cover regularly to prevent mould build up.
CLEANING THE AIR FILTER
1. At the front of the machine, pull the filter upwards and out, using the tab.
2. Wash the filter under running water to remove any dust and dirt.
3. Allow the filter to dry naturally.
4. Refitting is the reverse process.
NOTE: The frequency depends on the
duration and the level of dust in the environment. If the machine is being used regularly, it is recommended that you clean the filter every 2 weeks.
STORAGE
• Unplug from the mains socket.
• Empty any water from the tank.
• Clean and reinstall the filter.
• Cover the dehumidifier to prevent dust getting into the workings.
13
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 14
TROUBLESHOOTING
Cause Solution
No operation (Shown as no power)
No operation (Shown as power on)
Dehumidifier function not effective
Power outage Check if the power supply is in
working order.
Confirm the plug is correctly inserted in the power socket.
Fuse in plug or fuse board blown
Environmental humidity lower than the set value
The machine is defrosting Wait for defrosting to complete.
If a door or window are open
Room temperature is too low
Room temperature too high, humidity too low.
Replace the relevant fuse.
Reset humidity setting according to the demand.
Close the door or window.
Do not use the dehumidifier.
In dry conditions the dehumidification ability will reduce.
Air filter blocked. Remove any dirt or obstruction
Noise is abnormal during operation
Water Leak Connection of drainage
Frosting Occurs The ambient temperature is
Dehumidifier is positioned incorrectly.
Air filter blocked. Remove any dirt or obstruction
There is a ‘tittering’ sound. This is the flow of the refrigerant,
pipe become loose.
Drainage system is blocked.
low and the machine is waiting for defrost.
from the air intake.
Check that dehumidifier is placed on a flat level surface.
from the air intake.
which is a normal phenomenon.
Check pipe connection.
Remove obstacle and straighten out drainage pipe.
This is a normal phenomenon and the dehumidifier has an automatic defrost function.
14
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 15
DISPLAY CODES
Display Code Instruction Action
E1 Fault with coil sensor See Defrosting Mode.
E2/E3 Fault with humidity and/or
temperature sensor
EE Refrigerant leakage Contact CLARKE service
Replace temperature and humidity sensor.
department if EE signal remains.
ELECTRICAL DIAGRAM
15
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 16
COMPONENT PARTS DIAGRAM
16
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 17
COMPONENT PARTS LIST
No Description No Description
1 Handle 34 Water Tank Bracket
2 4 x Bolt & Nut, M6 x 35 35 Control Box
3 Handle Bracket 36 Power Strip
4 Back Cover 37 Fan Motor Capacitor
5 Discharge Pipe 38 Control Box Side Plate
6Suction Pipe 39Water Tank Bracket
7 Control Panel Label 40 Water Tank Support Plate
8 Control Panel 41 Main Body Base Plate
9 Control Panel Holder 42 Foot Bracket
10 Main Body Shell 43 Foot Pad
11 Motor Bracket 44 Wheel Axle, 16mm x 462mm
12 220V/50Hz Fan Motor 45 Wheel
13 250mm Fan Blade 46 Foot Rest
14 Partition Plate 47 Compressor Capacitor
15 Condenser 48 Compressor Bolt, M8 x 40
16 Evaporator 49 Compressor Mat
17 Bracing Rod 50 Compressor
18 Sensor Bracket 51 Power Cable
19 Temp. & Humidity Sensor 52 Power Cable Storage Clip
20 Sensor Cover
21 Air Filter
22 Front Cover Bracket
23 Front Cover/Grill
24 Water Tank Door
25 Door Hinge
26 Door Bracket
27 Water Drip Pan
28 Water Level Switch
29 Water Tank
30 Magnetron Switch
31 Magnetron Switch Holder
32 Water Level Switch Bracket
33 Water Tank Plug
17
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 18
DECLARATION OF CONFORMITY - UKCA
18
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 19
DECLARATION OF CONFORMITY - CE
19
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 20
Loading...