5.Storage
If the generator is to be stored for long periods, proceed as follows.Drain fuel tank, (fuel left in the tank for long periods will deteriorate causing difficulty
whentrying to start the engine).
Drain fuel from the carburettor.
Change the engine oil.
Wash the air cleaner.
Check for loose bolts etc, tighten any found.
Check for other defects, any defects should be rectified before continuing.
Clean generator thoroughly and apply a preservative spray if available.
Ensure the engine switch is in the STOP position.
Pull the starter handle until resistance is felt, leave in that position.
Store indoors in a well ventilated area, preferably with a low humidity level.
Observe extreme caution when draining the fuel tank, DO NOT pour fuel down drains etc,always dispose of fuel, oils and chemicals etc, according to local authority regulations.
WARNING
6.Specifications
Thank you for purchasing this CLARKE Portable Generator.Before attempting to use the equipment, please read this manual thoroughly and follow
the instructions carefully. In doing so you will ensure the safety of yourself and that ofothers around you, and you can look forward to the Generator giving you long andsatisfactory service.
CLARKE GUARANTEE
This CLARKE product is guaranteed against faulty manufacture for a periodof 12 months from the date of purchase. Please keep your receipt as proofof purchase.
This guarantee is invalid if the product is found to have been abused ortampered with in any way, or not used for the purpose for which it wasintended.
Faulty goods should be returned to their place of purchase, no product canbe returned to us without prior permission.
This guarantee does not effect your statutory rights.
Contents
Page No
Engine.
Generator.
Dimensions.
Dry Weight.
Type.Petrol / Forced air cooled / 4 stroke / Side valve.Displacement.92cc (5.61cv.in).Fuel Tank capacity.1.5 Litres.Ignition System.Solid state ignition.Starting System.Recoil.Continuous Rating.Approx 3-4 Hours (50Hz).
Type.Type.2 pole revolving field.Exciting System.Voltage Regulating
System.AC Frequency.50Hz.AC Voltage.230 vac.AC Max Output.700W 50Hz.AC Rated Output.600W 50 Hz.DC Output.12V 100W.Over Current
As with all machinery, there are certain hazards involved with their operation
and use. Exercising respect and caution will considerably lessen the risk of
personal injury. However, if normal safety precautions are overlooked or
ignored, personal injury to the operator or damage to property, may result.
1.
ALWAYS
hazards peculiar to it. Read and become familiar with the entireoperating manual.
2.
ALWAYS
any damaged part, should be checked to ensure thatit will operate properly, and perform its intendedfunction. Check for alignment of moving parts, breakageof parts, mountings, and any other condition that mayaffect the machines operation. Any damage should beproperly repaired or the part replaced. If in doubt, Consult your local dealer.
3.
ALWAYS
while the generator is operating.
4.
ALWAYS
etc.
5.
ALWAYS
best and safest performance. Follow maintenance instructions.
6.
ALWAYS
the generator. Surrounding areas should be free ofinflammables and hazardous materials (lubricants,celluloid items, explosives etc).
7.
NEVER
when refuelling.
8.
NEVER
up and allowed to dry thoroughly before starting the generator.
9.
NEVER
10.
NEVER
11.
NEVER
12.
NEVER
insufficient ventilation, such as a tunnel etc, ensure theexhaust pipe is directed towards a well ventilated openarea.
13.
NEVER
if connected, could lead to a malfunction, even worse, afire could result.
Exhaust fumes contain toxic gases. Extreme care must beobserved to ensure people an animals in the surrounding areas are not affected.
Learn the machines applications, limitations and the specific potential
check for damage. Before using the machine,
3ft
3ft
DO NOT
use the generator on a flat level surface. Avoid tilting or moving
switch the machine off before servicing and when refuelling
maintain machine in top condition. Keep clean for the
allow at least 1 metre (3ft) clearance around
smoke, use a naked flame or allow others to do so
overfill the tank, fill to the specified level only.Any spillagesmust be cleaned
cover or enclose in box etc.operate the generator indoors.operate the generator when raining or snowing.operate in enclosed area where there is
connect the generator to a residual power source,
WARNING
-3--12-
use the machine.
3ft
3ft
Engine Fails To Start
Engine switch and orchoke lever areincorrectly set.
Fuel tank empty.Check fuel level and top up as required.
Appliance connectedto the generator.
Spark plug !
Oil warning lampflashing.
No power supplied to the appliance
Circuit breaker tripped.Check the wattage of connected appliance is
Faulty connection atthe appliance.
If problems persist, contact Clarke service department for advice.
Set engine switch to RUN, move the chokelever to its uppermost position (CHOKE).Return choke lever to its normal position (RUN)when engine warms up.
If connected, turn off the power switch at theappliance or disconnect completely.
Check spark plug is connected correctly.Remove spark plug and clean.Fit new spark plug
Check oil level and top up as required.
within the permissible tolerance level of thegenerator, if OK, reset the tripped circuit breakerand resume as normal.
Check connections and make good if faultyone found.
PARTS & SERVICE TEL: 020 8988 7400
ore-mail as follows:
PARTS: Parts@clarkeinternational.com
SERVICE:Service@clarkeinternational.com
Page 5
Using the box spanner/plug spanner Fig. 11,loosen and remove the plug by turning in an
anticlockwise position.
Using a plug cleaner or wire brush, clean plugelectrode of burnt or deposited carbon.
2.Component Identification
Fig. 11
Check for correct gap betweenthe electrodes. Adjust gap to 0.6to 0.7mm (0.02 to 0.03) byreforming the electrode (Fig. 12).Recommended replacementplug type:
NGK - BMR4A
Refit spark plug in reverse order,DO NOT overtighten and takeextra care not to break ordamage the porcelain.
Carburettor Adjustment
NOTE: It shouldnt be necessary to adjust the carburettor air screw as this has been presetat the factory. before attempting to make further adjustments,we recommend that youcontact your nearest Clarke dealer for advice.
If it is necessary to make adjustments, remove the rubber grommet to gain access to theadjusting screw Fig. 13b (cut away view), to view the screw when making this adjustmentis possible by looking through the open spark plug cover.Replace rubber grommet when finished.
Champion - RCJ8
or
Porcelain
Fig. 12
Electrode
Spark Plug Gap
0.6~0.7mm(0.02~0.03)
A.Carry Handle.B.Fuel Filler Cap.C.Recoil Starter Handle.D.Earth Terminal (Ground).E.Dual AC Sockets.F.Indicator Lamp.G.AC Circuit Breaker.H.Low Oil Warning Lamp.I.Engine Control Switch.J.Negative DC Terminal.K.DC Circuit Breaker.L.Positive DC Terminal.M.Spark Plug Cover.N.Air Adjusting Screw (Internal).O.Choke Lever.P.Exhaust Outlet.Q.Tool Box.R.Air Cleaner Cover.S.Frequency Adjusting Screw
(Internal).
T.Oil Filler.
Fig. 13
ab
-11--4-
Page 6
3.Operation
Before operation, the following must be carried out,
Engine Oil Level
Ensure the generator is standing on a flat level surface and not running.
Unscrew anticlockwise, the oil filler plug/dipstick and remove.
Using a clean soft cloth or tissue, wipe the dipstick, insert the dipstick into the filler neckas shown, remove and check the level on the minimum and maximum marks, top up
as necessary with suitable oil.
SAE 10W-30 or 10W-40
oil is used, select the appropriate viscosity forthe average temperature in your area.
Oil Filler Plug/Dipstick
is recommended for general all temperature use. If single viscosity
MaxLevel
MinLevel
Max
Min
Fig. 1
Oil Filler Neck
Fig. 2
Fig. 9
Use as a plug spanner, insert the tommy bar into the holes in the top of the box spannerFig.9.Toaccess the plug, open the spark plug cover by pushing in at the bottom, Fig. 10a andlifting upwards, Fig. 10b.
Fuel Level
Check fuel level before starting the generator,by viewing the fuel gauge on top of thegenerator.If the tank requires filling, observe all the safetyaspects before doing so.
WARNING
Always connect a ground lead to the generatorbody when refuelling. One end of the leadshould be connected to the ground terminalbelow the recoil handle, the other to a goodknown ground.
NOTE: the generator should also be groundedwhen the appliance is grounded.
-5--10-
Tank Empty
Tank Full
Fig. 3
a
Pull the spark plug cap off to expose the sparkplug Fig. 11.
Fig. 10
b
Fig. 11
Plug Cap
Page 7
Air Filter
Siting The Generator
The air cleaner consists of threeparts, (Fig. 7).ToClean/replace the air filterproceed as follows.All parts removed must becarefully put to one side prior tocleaning and reassembling.
Using No 2 phillips screwdriverloosen (anticlockwise) and
remove the cover securingscrew, Fig. 7a.
Remove the air filter cover.
Withdraw filter element 1,Fig. 7b.
Withdraw the filter cage 2,Fig. 7c.
Withdraw filter element 3,Fig. 7d
Wipe out the air filter housingusing a clean soft cloth and a mild household detergent solution, DO NOT use chemicals
or harsh abrasives. Ensure the housing is dried thoroughly before reassembling. Carefullywash the filter elements in a clean detergent solution, remove excess solution and allowto dry thoroughly. Once dry soak the elements in amixture of 3 parts petrol to 1 partengine oil, squeeze out the excess oil and reinstall into generator.
NOTE:DO NOT twist the elements to remove the excess oil,just grasp and squeeze them tightly.
Spark Plug
Remove the spark plug using the plug spanner supplied, the spanner is stored in thetoolbox, underneath the generator (Fig. 8). Toaccess the spanner,remove the securingscrew, allow the box to hinge down on the R/H side and withdraw in direction of arrow.Toremove and clean the plug, proceed as follows.
a
Fig.7
2
c
1
b
3
d
The area should be free of inflammables and hazardous materials.
The generator is placed at least 1 metre away from buildings and other facilities.
The area must be well ventilated,
The generator must be positioned with the exhaust directed towards a well ventilatedopen space.
The generator must be positioned away from any type of open flame or sparks etc.
The generator must be positioned in a stable condition on a flat level surface.
The generator is not enclosed or blocked by obstructions such as pieces of wood andcardboard etc.
Engine Control Switch
The engine control switch has a built in fuel shut OFFvalve, this enables easy starting and stopping of thegenerator.The control switch has two positions, STOP and RUN.When finished using the generator, turn the switch tothe stop position, this not only switches the engine OFF,but also shuts the fuel OFF.
Fig. 4
Choke Lever
Starting the generator requires the choke lever to bemoved to the upper position (CHOKE).When the engine has warmed up, slowly move thelever down to the lower position (RUN).
Fig. 8
Tools included are universal, consisting of, 1 box spanner (plug spanner) and 1 tommybar/phillips screwdriver.Touse as a screwdriver, simply withdraw the tommy bar fromthebox spanner and insert the keyed end into the box spanner, see Fig. 9.
-9--6-
Indicator Lamp
Fig. 5
When the generator is running, the indicator lamp is ON (green). when the engine isswitched OFF, the indicator lamp is extinguished.
Oil Low Warning Lamp
When the oil level drops below the minimum level, the warning lamp flashes, if this shouldhappen, switch the generator OFF, allow five minutes to cool down and for the oil tosettle, check the oil level and top up as necessary, see maintenance, section 4.
Page 8
Battery Charging
Frequency Adjusting Screw
The DC output is used for charging 12volt batteries ONLY.Tocharge a 12volt battery, proceed as follows.ENSURE the generator is switched off by turning the engine control switch to the STOPpositionUsing suitable cables (not supplied), connect one end of the negative lead to thenegative terminal (BLACK) on the generator, and the other to the negative terminal onthe battery.Connect one end of the positive lead to the positive terminal (RED) on the generator,and the other end to the positive on the battery.Remove the battery caps and check the water level, top up with distilled water if required,Refit the caps, leaving slightly loose if battery not the sealed type, this will prevent thebuild up of dangerous gasses.Turnthe engine control switch to the run position, pull the recoil starter handle to start theengine.
NOTE:the charging time depends very much on the state of discharge! e.g. a fully discharged12v-40Ah auto battery will take approx 5 to 6 hours to fully charge,the charge level canbe checked using a hydrometer to measure the specific gravity in each cell.Take care when handling auto batteries as they contain acid,always wear protectivegloves and goggles when doing so.Always refer to specific battery manufacturers instructions before commencing anymaintenance.
Circuit Breakers
Both circuit breakers AC and DC are designed to cut the electric current when thecurrent exceeds its limit or a malfunction occurs in the connected appliance.The circuit breaker buttons are transparent with an internal coloured button which willpop out in the event of an overload etc.Before attempting to reset the relevant circuit breaker, switch the generator OFF, locateand rectify the reason for the tripped breaker.Once the fault is rectified, restart the generator, wait for a couple of seconds, depress thebreaker button, the internal coloured button should remain IN when the breaker buttonis released.If the circuit breaker continually trips out, and the cause cannot be traced, contact yournearest Clarke dealer for advice, alternatively, have the connected appliance checkedby a qualified electrician.Todetermine if the fault lies with the appliance or the generator itself, try connectinganother appliance, if the breaker still trips out, the fault is clearly within the generator, if itdoesnt trip, then the appliance must be at fault.
NOTE:When charging a large capacity battery,DC output will exceed the limit and the DCcircuit breaker will trip out and cut the current,this is normal,if this does happen,wait afew minutes,then reset the circuit breaker to resume charging,this applies only whencharging large capacity batteries.
The frequency is factory set and should not require furtheradjustment, however the frequency can be adjusted,simply by removing the rubber grommet in the front panelto gain access to the adjusting screw.Using a small phillips screwdriver adjust as required, replacethe grommet when finished.
NOTE:This adjustment should only be carried out by a competentperson.
Frequency Adjusting Screw
Fig. 6
4.Maintenance
Daily
Check engine oil level and top up as required.
Check generator for worn or broken parts, any found should be rectified before
continuing.
Wipe generator with a clean soft cloth, lightly moistened with water. DO NOT useharsh abrasive cleaning agents or chemicals which could damage certain parts.
Periodic
Item20hrs50hrs100hrs200hrs500hrs1000hrs
Clean air filter.Check & clean spark plug..Change engine oil...
Check & adjust plug gap....
Clean fuel filter....
Replace spark plug.....
Replace air filter.....
Clean carburettor.....
Remove carbon from cyl head.....
Check & adjust valve clearance.....
Check oil sensor system.....
Overhaul (CLARKE Service)......
Check engine switch.....
Check rotor......
Check stator......
Check engine mounts......
#
.....
#
....
#
...
##
....
######
##
HighLow
......
#
###
WARNING
Always ensure any appliances are switched OFF/disconnected
before starting the generator.