Clarke ECP 20A1, 7120405 User guide

Page 1
Page 2
INTRODUCTION
Thank you for purchasing this Clarke Water Pump.
This non-submersible centrifugal pump is ideal for a range of domestic and light agricultural purposes.
It is designed to pump clean water in gardens for spraying and irrigation and for pumping water to greenhouses. It can also be used for boosting running water feed pressure (not drinking water) and for pumping out wells and ponds. It is not designed for use with contaminated or salt water. If used for pumping water from a pond, extra filtering measures should be taken to isolate any larger particles.
Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.
WARNING: THIS SYMBOL IS USED THROUGHOUT THE USER GUIDE WHENEVER THERE IS A RISK OF PERSONAL INJURY. ENSURE THAT THESE WARNINGS ARE READ AND UNDERSTOOD AT ALL TIMES.
Your CLARKE water pump has been designed to give long and trouble free service. If, however, having followed the instructions in this booklet carefully, you encounter problems, take the unit to your local Clarke dealer.
Please keep these instructions in a safe place for future reference.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not effect your statutory rights.
2
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 3
GENERAL SAFETY PRECAUTIONS
Before using this equipment it is in your own interest to read and pay attention to the following safety rules.
WARNING: ALWAYS CONNECT THE PUMP TO AN EARTHED POWER SUPPLY VIA AN RCD.
1. NEVER use for pumping flammable liquids or corrosive chemicals. This pump is designed to pump clean water only.
2. ALWAYS keep the working area clean and well lit. Floors should always be kept clear. Cluttered or dark areas invite accidents.
3. NEVER over-reach. Keep your proper footing and balance at all times when installing or maintaining the pump.
4. NEVER direct any water discharge towards electrical wiring or equipment.
5. ALWAYS thoroughly familiarise yourself with this pump & its operation, and follow all instructions in this manual. Never allow persons unfamiliar with these instructions to instal or operate the pump.
6. ALWAYS ensure that the pump is properly installed to prevent it from moving during operation, and that the immediate area surrounding the pump is kept clear.
7. ALWAYS maintain the pump with care and keep it clean for best / safest performance.
8. NEVER use this product if any part is damaged. Have it inspected and repaired by your local Clarke dealer. Always turn the pump off before carrying out any maintenance.
9. NEVER modify this pump in any way. Use it ONLY for the purpose for which it is designed.
10. ALWAYS have the pump serviced by your local Clarke dealer, using only identical replacement parts. This will ensure the safety of the pump is maintained. The use of non standard parts could be hazardous.
11. NEVER allow the pump to run dry.
CAUTION: THIS PUMP IS NOT A SUBMERSIBLE PUMP. ON NO ACCOUNT SHOULD IT EVER BE IMMERSED IN WATER.
3
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 4
INSTALLATION
Because of the number of possible installations, no accessories are supplied with your pump except for a pair of male inlet/outlet adaptors. However accessories are available from your nearest Clarke dealer. See the suggested list on page 13.
NOTE: It is recommended that the end user should consult a qualified
installer if there are any doubts as to the suitability of this product for a particular installation.
IMPORTANT: The pump MUST NOT be connected to the mains power supply until all hose/pipe installation is completed.
INSTALLATION OF THE PUMP
The pump must always be installed and operated in a horizontal position i.e. with the outlet port facing vertically upwards. The fixing holes in the base should be used to secure the pump firmly in it’s operating position. Mount the pump on raised blocks or a purpose built platform to protect it from flooding. Some kind of anti-vibration mounting is also desirable.
Always ensure there is adequate air circulation around the motor. The pump should be installed in a dry, well ventilated enclosure, sheltered from rain.
ELECTRICAL INSTALLATION
The pump should be located at such a distance away from any pond or pool, as to avoid the possibility of immersion and the power supply should also be a safe distance away. If in doubt, please contact your electrical specialist and refer to national regulations.
Avoid situations where the pump could become drenched with water as neither the motor or terminal box are designed to be totally waterproof. Ensure the pump & its power cable do not create a safety hazard for people walking past it.
Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz. Connecting it to any other power source may cause damage.
4
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 5
Page 6
PIPE/HOSE CONNECTIONS
The pump inlet and discharge ports are both 2” BSP (51 mm) female
threads and accept the adaptors supplied.
Hoses with the same diameter should be used and secured to the adaptor with a suitable hose clip.
Ensure all connections are air tight when under pressure but not so tight as to crack the plastic inlet/outlet adaptors.
ADDITIONAL CONSIDERATIONS
• Strain caused by vibration can be reduced by connecting a short
flexible hose between any rigid pipework and the pump.
• We recommend that you always use pipes/hoses with a minimum
diameter of 2” (51 mm).
• Any restriction in the pipeline will greatly reduce the flow.
• Ensure that the hoses and pipes are supported along their entire
length. They will be considerably heavier when filled with water.
• We recommend that you install isolation valves either side of the
pump in order to isolate the pump during maintenance/removal.
• A gate valve may be installed in-line on the delivery side of the
pump which can be adjusted as required to regulate the flow of water and can assist in priming the pump.
• If there is any chance of freezing, protect the pump and pipework
with suitable lagging. The formation of ice may cause serious damage.
6
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 7
USEFUL ACCESSORIES
2” BSP Plastic Foot Valve Filter FVF20
2” dia Reinforced Suction/Delivery Hose Part No:7955020
2” dia Layflat Delivery Hose 10M
2” BSP Female Coupling
2” BSP Male Coupling Part No:7950220
o
2” Hose Adaptor 90
Bend
Part No:7950684
Part No:7955160
Part No:7950320
Part No:7950205
SUCTION LIFT OR GRAVITY FEED
There are two possible methods of pipework installation.
1. Suction Lift. Used to draw clean water from a pool or well providing the vertical distance between the foot valve and the pump does not exceed the 8 metres specified for this pump.
It is essential that all connections and hoses are airtight or the system will not work effectively.
A foot valve/filter fitted to the lower end of the suction hose, (as illustrated), is essential to retain water in the system as the pump is not self priming.
2. Gravity Feed. Used to draw water. from a tank above ground.
7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 8
PRIMING THE PUMP
Before using the pump for the first time the inlet (suction) side must be
filled with water to prime the pump as follows:-
1. With all inlet pipes/hoses, but no outlet hose connected, pour water into the outlet port until all the air is expelled.
2. Connect the outlet hose to the outlet port.
If the outlet hose is already connected, a priming port and threaded plug are provided, adjacent to the outlet as shown.
NOTE: As the priming hole is quite small, it is necessary to fill the inlet
(suction) pipe with water before connecting to the pump, and top up through the priming port once the pipe is connected. A non-return valve will need to be fitted to the inlet pipe for this purpose.
3. Switch on the pump.
• Water should start to flow through the system.
4. Check for leaks and correct if necessary.
5. Adjust any device such as a non-return valve, which may be fitted to the outlet side of the pump, to maximise efficiency.
• Do not place any restriction on the inlet or discharge hoses.
Remember - this pump is designed for pumping CLEAN WATER ONLY. DO NOT USE for pumping chemicals or other flammable or corrosive liquids.
8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 9
OPERATION
1. Open any valves in the pipeline.
2. If operating the pump for the first time, prime the pump as described. on page 8.
NOTE: Refilling (re-priming) is only necessary if the pump has been
drained.
3. Connect to the power supply and switch on.
• When water starts to flow through the system check for leaks and
correct if necessary.
• If the motor fails to start or the pump does not deliver water, refer to
TROUBLESHOOTING.
• Never operate the pump when not primed with water or if the inlet is
blocked which would allow the pump to run dry, causing damage.
NOTE: Filling the suction pipe with water will speed up the priming
process, and it is important that a non-return valve be fitted to the end of the suction pipe.
4. Stop the pump by switching off the power supply.
CARE DURING USE
1. Do not allow the pump to run dry, otherwise the seal between the pump and motor may be damaged. If a leak occurs at this point, allowing water to pass from the pump to the motor, take the pump to your Clarke dealer for overhaul.
2. In the event of a blockage, where debris has entered the pump, it can be cleaned out as described under MAINTENANCE.
3. DO NOT USE for pumping chemicals or other corrosive liquids. Should contaminants enter the pump, flush through with water as soon as possible to prevent damage.
4. If the pump is being used to drain a pool, ensure there is adequate drainage and there is no risk of damage to property as a result of water being discharged. If a flexible hose must be laid across a roadway, protect it with wooden planking.
9
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 10
MAINTENANCE
Inspect the pump/hoses regularly to ensure that debris is not blocking the passage of water.
If you suspect the pump is blocked by silt, leaf debris etc, disconnect it from the power supply, disconnect the discharge hose and back-flush to clear any blockage using a hosepipe.
Always keep the pump in a clean condition and check regularly for damage to the power cable etc.
AFTER USE
After use, and if the pump will not be used over the winter period, or if there is danger of freezing, always drain the pump body.
If the pump has been used with contaminated or salty water, it should be thoroughly flushed with clean water following use, both inside and out. It should then be drained and covered over, if not already sheltered from the weather.
If the pump is seized following a period of inactivity, it may be possible to free it off. Ensure the pump power supply is turned off before by inserting a screwdriver into either the infeed or discharge port and dislodging a jammed impeller. If this is not successful it may be necessary to remove the relevant mounting bolts to separate the pump body and clean away any incrustation.
Re-prime the pump when returning to service.
In the event that overhaul of the pump or motor is necessary, contact your Clarke service department.
ENVIRONMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
10
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 11
TROUBLESHOOTING
Problem Cause Solution
Pump does not run. Thermal protection has
been activated.
Faulty power connection Insert plug securely.
No mains supply Check power supply and
Impeller seized/blocked Disconnect pump from
Pump fails to prime Air leaks through suction
hose joints (damaged hose, broken clamp.
Blocked inlet hose Check pipeline for block-
Sudden loss of flow. Blockage of inlet pipe Check pipe for blockage.
Pump runs but gives poor output
Congested material inside pump
Suction or delivery line obstructed.
Inlet pipe leakage. Check inlet pipe and
Air leaks through damaged seal.
Impeller damaged and making poor seal.
Impeller / mechanical seal is badly worn.
High friction losses in the suction line.
If the motor has over­heated, wait for it to cool before trying again.
replace fuse if necessary (check fuse rating). Check circuit breaker
power supply. Investigate cause & clear blockage
Repair connections/ replace hose as necessary.
age. Check any inlet valve fitted is fully open.
Clean out & backflush pump.
Remove obstruction and ensure there are no kinks in delivery line.
connector for leaks. Tighten as required.
Renew seal.
Return to your Clarke dealer for repair
Return to your Clarke dealer for repair.
Avoid unnecessary curves restrictions or valves
11
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 12
Pump badly sited result­ing in suction lift too high
Undue vibration or noise. Excessive flow of water. Decrease flow of water.
Resistance in inlet pipe caused by obstruction.
Loose rotating component
Installation of pump is unstable.
Air pocket in pump or pipeline.
Damaged impeller Return to your Clarke
Set pump as close as pos­sible to the level of the water to be pumped
by adjusting inlet/outlet valves in system.
Check pipe and clean out as necessary
Return to your dealer for repairs.
Stop pump and re-position.
Release plug in impeller housing to release air.
dealer for repair.
SPECIFICATION
Model ECP20A1
Water Classification Clean
Maximum Delivery
Rated Head 4-20 m
Maximum Suction Lift 8 m
Operating Temperature
Ingress Protection Rating IP x4 (splashing water)
Duty Cycle S1 Continuous
Supply 230V / 50Hz / 1ph
Rated Input Power 1700 W
Outlet Thread Size 2” BSP
Weight 28.2 kg
Length x Width x Height 450 x 242 x 325 mm
Sound Pressure Level 63.0 dB LpA
Sound Power Level 71.0 dB LwA
400 l/min (23.9m
o
C
0-40
3
/hr)
12
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 13
ECP20A1 PARTS DIAGRAM
ID DESCRIPTION ID DESCRIPTION ID DESCRIPTION
1 Pump Casing 14 Bolt 27 Locking Washer
2 Discharge Plug 15 Pump Support 28 Fairlead
3 O-Ring 16 Drops Guard 29 Stand
4 Nut 17 Spring Washer 30 Stator Winding
5 Snap Ring 18 Bolt 31 Bearing
6 Washer 19 Motor Housing 32 Rotor
7 Key 20 Terminal Board 33 Bearing
8 Impeller 21 Grounding Mark 34 Circlip
9 Circlip 22 Terminal Box Cover 35 Screw
10 Washer 23 Screw 36 Back Cover
11 O-ring 24 Capacitor 37 Bolt
12 Mechanical Seal 25 O-ring 38 Fan
13 Seal Holding Disc 26 Screw 39 Fan Cover
13
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 14
DECLARATIONS OF CONFORMITY-UK
14
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 15
DECLARATIONS OF CONFORMITY-CE
15
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 16
Loading...