Only suitable for well insulated areas and not designed
to be the primary heat source
400V ELECTRIC FAN HEATER
MODEL NO: DEVIL 5000PTC
PART NO: 6925340
OPERATION & MAINTENANCE
INSTRUCTIONS
ORIGINAL INSTRUCTIONS
GC0621 rev 1
Page 2
INTRODUCTION
Thank you for purchasing this CLARKE product.
Before attempting to use this product, please read this manual thoroughly and
follow the instructions carefully. In doing so you will ensure the safety of yourself
and that of others around you, and you can look forward to your purchase
giving you long and satisfactory service.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt which will be
required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for the purpose for which it was
intended.
Faulty goods should be returned to their place of purchase, no product can
be returned to us without prior permission.
This guarantee does not effect your statutory rights.
SPECIFICATIONS
Operating Voltage and Frequency: 400 V / 50Hz / 3 Phase
Operating Temperature: (Min/Max) -15 to +25°C
Max Heat Output:5 kW - 17060 BTU/HR
Air Output:
Safety Device:Thermal cut-out
Duty Cycle Classification:Continuous duty
Electrical Insulation ClassI
Ingress protectionIPX0
Product: Depth x Width x Height300 x 235 x 345 mm
Product Weight4.32 kg
2
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
588m
3
/h
Page 3
THE FOLLOWING TABLE ADDRESSES THE
INFORMATION REQUIREMENTS OF REG.2015/1188
ItemSymbolValueUnit
Heat output
Measured seasonal space heating energy efficiency36%
Nominal heat outputP
Minimum heat output (indicative)P
Maximum continuous heat outputP
Auxiliary electricity consumption
At nominal heat outputel
At minimum heat outputel
In standby modeel
Type of heat input for electric storage local heaters only
Manual heat charge control with integrated thermostatNo
Manual heat charge control with room and/or outdoor temperature
feedback
Electronic heat charge control with room and/or outdoor temperature
feedback
Fan assisted outputNo
Type of heat output/room temperature control (select one)
Single stage heat output, no temperature controlNo
Two or more manual stages, no temperature controlNo
With mechanical thermostat temp controlYes
With electronic temperature controlNo
Electronic temperature control with day timerNo
Electronic temperature control with week timerNo
Other control options (multiple selections possible)
Room temperature control with presence detectionNo
Room temperature control with open window detectionNo
Room temperature control with distance control optionNo
Room temperature control with adaptive start controlNo
Room temperature control with working time limitationNo
Room temperature control with black bulb sensorNo
nom
min
max
max
min
SB
5kW
3.3kW
5kW
n/akW
n/akW
0kW
No
No
3
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 4
SAFETY ADVICE
Make sure that you read, understand and comply with the following.
ELECTRICAL SAFETY
WARNING: THIS HEATER MUST BE EARTHED
• Regularly inspect the power cable / plugs to be used with this heater
and do not use the heater it the power cable is damaged.
• Minimise the risk of electric shock by installing a RCCB (Residual Current
Circuit Breaker) and a suitable 3-phase isolator into the main distribution
board.
• Make sure that the voltage on the rating plate is the same as the
voltage of the power supply. If in doubt, consult a qualified electrician.
• DO NOT abuse any electrical cable used with this heater. NEVER use the
cable for pulling or unplugging the heater.
• Keep the cable away from sources of heat, oil, sharp edges or moving
parts. Damaged or tangled cables increase the risk of electric shock.
OPERATION
• The heater must only be used by persons who have read these
instructions and have been trained in its use.
• DO NOT obstruct the air inlet and outlet sections of the heater.
• DO NOT cover the heater.
• DO NOT touch the heater casing or grille when first switched off, as these
will be very hot and will take time to cool.
• DO NOT get the heater wet or use in areas of high condensation.
• DO NOT allow the power cable to touch hot surfaces.
• DO NOT connect other appliances to the same mains socket as the
heater.
• Only use the heater in an level position.
• DO NOT use this heater with a programmable timer used to switch it on
automatically.
4
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 5
POSITIONING
WARNING: DO NOT USE THE HEATER NEAR FLAMMABLE MATERIAL,
LIQUIDS, SOLIDS, GASES OR COMPRESSED GAS CYLINDERS ETC.
• This heater is designed for indoor use only.
• DO NOT place the heater close to a bath, wash basin, shower, swimming
pool or any other water-filled area or wet surface. DO NOT place the
heater up against any surface such as a wall, door or furniture etc.
• DO NOT place the heater immediately below any electrical outlet.
• NEVER place the heater near combustible materials such as curtains,
furniture etc. Allow at least 2 metre clearance.
• DO NOT place the heater on a raised surface or anywhere where it
could topple over.
• ALWAYS ensure that the grille cannot be blocked by curtains or other
fabrics.
• DO NOT operate in explosive atmospheres such as in the presence of
flammable liquids, gases or dust such as in a paint spray booth or any
explosive environment. Electric motors create sparks which may ignite
dust or fumes.
• DO NOT leave the heater un-attended, for example, left on at night.
COMMON SENSE
• DO NOT operate when you are tired or under the influence of alcohol,
drugs or intoxicating medication.
• DO NOT stand on the heater.
• DO NOT use the heater with wet hands or when there is water on the
power cable.
• Turn the heater off when not in use and keep it in a safe, dry, childproof
location.
• The heater is designed to heat enclosed areas larger than 4m
workshops and other industrial areas. Do not use the heater for any other
function. It is not suitable for drying clothes or laundry.
• Young children must be kept away unless continuously supervised.
• DO NOT touch the heater casing or grille during use.
5
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
3
, such as
Page 6
MAINTENANCE.
WARNING: SERVICING OR INTERNAL MAINTENANCE MUST ONLY BE
CARRIED OUT BY THE CLARKE SERVICE DEPARTMENT.
• Check that the heater is in good working order. Take immediate action
to repair or replace damaged parts.
• DO NOT allow the heating elements to become covered with dust
which could become a fire hazard. If used in a dusty workplace it should
be cleaned as described under Cleaning and Maintenance.
• ONLY recommended parts should be used. Unapproved parts may be
dangerous and will invalidate the warranty.
• DO NOT attempt to repair a damaged heater, contact the CLARKE
service department.
SERVICE & REPAIRS
• Have your heater repaired by a qualified person using identical
replacement parts. This will ensure that the safety of the heater is
maintained.
SAFETY SYMBOLS
The following symbols appear on the unit.
Hot
surface,do not
touch
Do not
cover
Read the
manual
ENVIRONMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the
obligation to deal with the WEEE in accordance with the WEEE
regulations in relation to the treatment, recycling & recovery and
environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal
facility.
6
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 7
ELECTRICAL CONNECTIONS
WARNING: THE INSTALLATION OF THIS APPLIANCE SHOULD BE CARRIED
OUT BY A COMPETENT ELECTRICIAN AND BE IN ACCORDANCE WITH THE
CURRENT IEE WIRING REGULATIONS (BS7671-2:2008).
This heater MUST be connected to a 400 Volt, 3 phase 50Hz supply through a
suitably rated isolator switch. It cannot be operated from a single phase
supply.
In addition to the cable fitted to the
heater, a DCL16B extension lead can
be used. This is fitted with a red 5 pin
16 amp industrial plug to EN 60309
with 16A socket. (CLARKE part No
6925233).
If in any doubt, consult a qualified electrician. DO NOT attempt any electrical
repairs yourself.
OPERATION
WARNING: DO NOT USE THIS HEATER IN SMALL ROOMS WHEN THEY ARE
OCCUPIED BY PERSONS NOT CAPABLE OF LEAVING THE ROOM ON THEIR
OWN, UNLESS CONSTANT SUPERVISION IS PROVIDED.
CAUTION: SOME PARTS OF THIS PRODUCT CAN BECOME VERY HOT AND
CAN CAUSE BURNS. PARTICULAR ATTENTION HAS TO BE GIVEN WHERE
CHILDREN AND VULNERABLE PEOPLE ARE PRESENT.
1. Put the heater in a level position
on a flat surface and at a safe
distance from flammable
materials. Keep a minimum of 2m
clearance all round.
2. Connect the heater to a suitable
power supply.
3. Set the thermostat control to the
maximum setting (fully clockwise).
7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 8
4. Set the mode selector to one of
the 3 settings:
Off
Fan Only
Heat Setting 1
Heat Setting 2
• The heater will take up to three minutes to reach optimum temperature.
5. Once the room reaches the required temperature, turn the thermostat
control slowly counter-clockwise until the thermostat clicks, leave the
control in this position.
• The room temperature will be maintained at this setting. The heater will
continue to operate until the power switch is turned to the OFF position.
6. For fan only operation, turn the
power switch to the fan only
setting and set the thermostat to
its minimum setting.
7. Adjust the angle by loosening
both adjusting knobs and setting
the required angle.
8. Retighten the adjusting knobs.
9. When not in use, disconnect the
heater from the mains supply.
Store it in a safe, dry, childproof
location.
8
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 9
TROUBLE SHOOTING
ProblemPossible CauseRemedy
Heater does not
operate,
although
plugged in with
the switch and
thermostat
switched on.
Heating element
glowing hot.
The unit has failed
to heat up so only
the air fan has
operated.
Abnormal noise.Heater is not level. Stand heater on a level surface.
Plug is loose/bad
connection.
Fuse blown or
circuit breaker
trips.
No power at
socket outlet
Input voltage too
high.
Air inlet grille is
blocked.
Control switch not
set at a "HEATING"
level.
Thermostat has
tripped.
Pull the plug out & check all
connections (cable/plug and socket).
Replace if necessary and investigate
cause. If fuse blows repeatedly, consult
your CLARKE dealer.
Insert the plug in a suitable socket.
Use a power supply in accordance
with the rating on the label.
Ensure the heater is kept away from
any objects which could cover the air
inlet or be drawn into it.
Turn switch to a heating level.
Turn the thermostat and listen. If there is
no CLICK and the thermostat is not
damaged, the heater will
automatically switch ON when it has
cooled down.
MAINTENANCE
WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY AND ALLOW
THE HEATER IT TO COOL DOWN BEFORE PERFORMING ANY
MAINTENANCE TASKS.
Clean the heater with a soft damp cloth. Do not use solvents or abrasives.
Make sure that the heater grill is not blocked.
No other maintenance is required, should you discover any problem with the
heater, return it to the CLARKE service department for repair.
9
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
Page 10
COMPONENT PARTS
1Setting knob15Friction pad
2Thermostat control knob16Relay support
3Lamp cover17Blade fastening
4Control box cover18Fan
5Switch19Motor
6Thermostat20Cable clamp
7Capacitor21Power cable/plug
8Relay22Motor bracket
9Front grille23Rear grille
10Air outlet24Temperature sensor
11Temperature controller25Surround
12Heating element26Foot pad
13Air duct27Housing
14Adjusting knob28Frame
10
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com